Preferred Language
Articles
/
jcofarts-740
Technological development and its association with the formal change to devices Flatiron: يوجل عبد الحسين فارس
...Show More Authors

Evolution in the modern era Which led to the rapid change in the forms of industrial products For many reasons, So put current research into question the view (What are the design requirements that define the formal change in the Iron clothes)? To reach the aim of In the design cornerstonesUnderlying the formal changethe Iron of the clothes, In the first section shed light on the development stages of systems design lists the historic stages of development and energy operator devices irons and mechanism of action and internal components, while in the second part, which was entitled (The role of technology and the factors influencing the change formality of Iron) touched on the three topics which technology modern industrial and receiver, as well as technological development and formal change and last topic is the role of the designer in the user accepts the morphological changes of industrial products, and research found that formal change subject effectively on the evolution in the field of technology

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Feb 18 2020
Journal Name
Modelling And Simulation In Engineering
Temperature and Stress Evaluation during Three Different Phases of Friction Stir Welding of AA 7075-T651 Alloy
...Show More Authors

The current study performs an explicit nonlinear finite element simulation to predict temperature distribution and consequent stresses during the friction stir welding (FSW) of AA 7075-T651 alloy. The ABAQUS® finite element software was used to model and analyze the process steps that involve plunging, dwelling, and traverse stages. Techniques such as Arbitrary Lagrangian–Eulerian (ALE) formulation, adaptive meshing, and computational feature of mass scaling were utilized to simulate sequence events during the friction stir welding process. The contact between the welding tool and workpiece was modelled through applying Coulomb’s friction model with a nonlinear friction coefficient value. Also, the model considered the effect of nonlin

... Show More
View Publication Preview PDF
Scopus (48)
Crossref (30)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Aip Conference Proceedings
Lab on-a-chip-based, an integrated microfluidic device lo-cost, rapid, and sensitive analysis of Augmentin
...Show More Authors

Microfluidic devices provide distinct benefits for developing effective drug assays and screening. The microfluidic platforms may provide a faster and less expensive alternative. Fluids are contained in devices with considerable micrometer-scale dimensions. Owing to this tight restriction, drug assay quantities are minute (milliliters to femtoliters). In this research, a microfluidic chip consisting of micro-channels carved on substrate materials built using an Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters influence the chip’s width, depth, and roughness. To have a regular channel surface, and low roughness, the laser power (60 W), with scanning speed (250 m/s)

... Show More
View Publication
Scopus (6)
Crossref (4)
Scopus Crossref
Publication Date
Tue Feb 18 2020
Journal Name
Modelling And Simulation In Engineering
Temperature and Stress Evaluation during Three Different Phases of Friction Stir Welding of AA 7075-T651 Alloy
...Show More Authors

The current study performs an explicit nonlinear finite element simulation to predict temperature distribution and consequent stresses during the friction stir welding (FSW) of AA 7075-T651 alloy. The ABAQUS® finite element software was used to model and analyze the process steps that involve plunging, dwelling, and traverse stages. Techniques such as Arbitrary Lagrangian–Eulerian (ALE) formulation, adaptive meshing, and computational feature of mass scaling were utilized to simulate sequence events during the friction stir welding process. The contact between the welding tool and workpiece was modelled through applying Coulomb’s friction model with a nonlinear friction coefficient value. Also, the model considered the effect o

... Show More
View Publication
Scopus (48)
Crossref (30)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Indian Journal Of Dental Research
Biomechanical finite element analysis of a single implant threaded in anterior and posterior regions of maxilla bone
...Show More Authors

Context: The ability of implant dentistry to be a successful alternative for edentulous patients has increased in the last decade. Clinical features such as osseointegration and stability, in addition to the endurance of the integration urged the researchers towards a better understanding of the design parameters that control long term success of the implants. It is therefore necessary to quantify the effect of changing implant design parameters on interface stress distribution within the maxilla bone. Methods and Materials: A 3D-finite element study was conducted to investigate the effect of changing implant shape parameters (implant body design and implant thread depth) on stress distribution while insertion of the implant in two diff

... Show More
View Publication
Scopus (12)
Crossref (13)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Ieee Access
Transfer Learning and Hybrid Deep Convolutional Neural Networks Models for Autism Spectrum Disorder Classification From EEG Signals
...Show More Authors

View Publication
Scopus (39)
Crossref (45)
Scopus Clarivate Crossref
Publication Date
Fri Dec 20 2024
Journal Name
Iraqi Journal Of Pharmaceutical Sciences
Genetic Polymorphisms at TNF-Alpha Receptors Associated some Autoimmune Diseases and Response of Anti-TNF Biologics: Review
...Show More Authors

Some genetic factors are not only involved in some autoimmune diseases but also interfere with their treatment, Such as Crohn's disease (CD), Rheumatoid Arthritis (RA), ankylosing spondylitis (AS), and psoriasis (PS). Tumor Necrosis Factor (TNF) is a most important pro-inflammatory cytokine, which has been recognized as a main factor that participates in the pathogenesis and development of autoimmune disorders. Therefore, TNF could be a prospective target for treating these disorders, and many anti-TNF were developed to treat these disorders. Although the high efficacy of many anti-TNF biologic medications, the Patients' clinical responses to the autoimmune treatment showed significant heterogeneity. Two types of TNF receptor (TNFR); 1 an

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (6)
Scopus Crossref
Publication Date
Fri May 28 2021
Journal Name
Journal Of Microbiology And Biotechnology
Bioactive Levan-Type Exopolysaccharide Produced by <i>Pantoea agglomerans</i> ZMR7: Characterization and Optimization for Enhanced Production
...Show More Authors

View Publication Preview PDF
Scopus (29)
Crossref (29)
Scopus Clarivate Crossref
Publication Date
Mon Apr 03 2023
Journal Name
Polymer Composites
Effect of silver nanoparticles on structural, thermal, electrical, and mechanical properties of poly(vinyl alcohol) polymer nanocomposites
...Show More Authors

View Publication
Scopus (39)
Crossref (40)
Scopus Clarivate Crossref
Publication Date
Wed May 01 2019
Journal Name
Environmental Technology &amp; Innovation
Biomineralization based remediation of cadmium and nickel contaminated wastewater by ureolytic bacteria isolated from barn horses soil
...Show More Authors

View Publication
Scopus (114)
Crossref (102)
Scopus Clarivate Crossref
Publication Date
Mon May 01 2023
Journal Name
Journal Of Engineering
Parametric Analysis of Surface Roughness and Metal Removal Rate during Electrical Discharge Machining of O1 Tool Steel
...Show More Authors

This work studies the impact of input machining parameters of Electrical Discharge Machining (EDM) on the machining process performance. Tool steel O1 was selected as the workpiece material, copper as the electrode material, and kerosene as the dielectric medium. Experimental runs have been carried out with a Design of Experiment (DOE) technique. Twenty tests are accomplished with the current range of (18 to 24 Ampere), a pulse duration range of (150 to 200 µs), and a pulse-off time range of (25 to 75 µs). Based upon the experimental study's output results, the EDM parameter's effect (voltage of power supply, discharge current, pulse duration, and pulse pause interval) on the responses of the process represented by sur

... Show More
View Publication Preview PDF
Scopus Crossref