The current research deals with studying the aesthetics of symbolic values in the design of internal spaces and their connotations through their existence as a material value, as well as the symbolic meanings and their connotations that touch the spiritual and emotional side of the human being as an intangible value, and the research included four chapters, so the research problem was embodied by the following question (What is the role of values Symbolism and aesthetics in the design of interior spaces)? Therefore, the aim was to clarify the role of symbolic values and their aesthetics in the design of internal spaces. The first chapter included the importance of research, the need for it, the limits of the research and its terminology. The second chapter included a detail of the theoretical framework that we relied on, which consisted of two topics. Internal design: Through these investigations, the theoretical framework indicators that feed into the topic of the research were reached, which helped in reaching a systematic method of research adopted in the third chapter, which included the research procedures, as we adopted the descriptive approach of the research community according to the justifications we clarified for analysis through frame indicators The theoretical, as for the fourth chapter, it included a review of the results, the most prominent of which was that the (Berlin) theater preserved the traditional form as a symbolic value and did not deviate from the familiar context of the design during the period in which it was established. As for the (Hamburg) theater, it achieved formal liberation and departed from the familiar system to express the strangeness and excitement Its shape as a symbolic value, while the conclusions were the most prominent of which was that the difference in intellectual orientations and within the period in which the whole theater was created led to the difference. In the aesthetics of the symbolic value of theater
The research problem lies in determining the beauty ranges between the receiver and the industrial product, The goal of the research, it is the definition of aesthetics in industrial design and its relation to the receiver, and the researcher outcome several conclusions of the, the most important was: 1. The role of accumulated experience, and their interaction with the vision of the artwork in achieving aesthetic perception and levels of artistic and aesthetic values and by the level of growth this taste of the recipient. 2. There are interactive and close relationship be the primary means for the integration of functional and aesthetic meaning the designer meant to get it to the receiver.
In this research a computational simulation has been carried out on the design and properties of the electrostatic mirror and a mathematical expression has been suggested to represent the axial potential of an electrostatic mirror. The electron beam path using the Bimurzaev technique had been investigated as mirror trajectory with the aid of Runge – Kutta method. The spherical and chromatic aberration coefficients of mirror has computed and normalized in terms of the focal length. The choice of the mirror depends on the operational requirements. The Electrode shape of mirror two electrodes has been determined by using package SIMION computer program. Computations have shown that the suggested potentials giv
... Show MoreThe natural ventilation in buildings is one of effective strategies for achieving energy efficiency in buildings by employing methods and ways of passive design, as well as its efficiency in providing high ranges of thermal comfort for occupants in buildings and raises their productivity. Because the concept of natural ventilation for many people confined to achieve through the windows and openings only, become necessary to provide this research to demonstrate the various passive design strategies for natural ventilation. Then, research problem: Insufficient knowledge about the importance and mechanism of the application of passive design strategies for natural ventilation in buildings. The research objective is: Analysis of passive desi
... Show MoreThe change in the size of the droplets during the pesticide application process could have a negative impact on the percentage of drift or the losses of pesticides to the environment. One of the factors that could affect the droplet size produced from a single nozzle is the internal design of the nozzle itself, in addition to the wear of the nozzle orifice as a result of the usage time. In this research, three types of nozzles with different internal designs were used (Turbo TeeJet (TT), Turbo TwinJet (TTj 6011003), and Drift Guard (DG 11003)). The nozzles were subjected to an accelerated wear test for one hundred hours, and different droplet size parameters (Dv 0.1, Dv 0.5, Dv 0.9),
Designed Mirrors double and triple package adoption concept heap where they were changing the thickness of the layers within periodic basis of the pile and different ratios (p: q) in addition to change the refractive index of materials within periodic basis and its impact on sites Dhour tops high reflectivity study included spectral region visible and infrared, depending on NdharahFeatured matrix adjusted fall of light close to the vertical arrangement multilayer dielectric materials and thin films homogeneous and uniform
In this paper, a solar concentrator is designed in the form of a concave half-cylindrical mirror consisting of polygonal reflective surface plates. The plates are arranged to give a hemispherical shape to the design. These surfaces work to receive solar radiation and focusing by reflecting it to the receiver that is placed in front of the reflecting surfaces. The results are compared with a system consisting of a concave reflecting surface of the same dimensions to obtain a good criterion for evaluating the design performance. The results showed a low acceptance angle for the design for all the samples used due to the geometrical design nature. The optical efficiency affected by the angle of incidence greatly by
... Show More
In today's world, most business, regardless of size, believe that access to Internet is imperative if they are going to complete effectively. Yet connecting a private computer (or a network) to the Internet can expose critical or confidential data to malicious attack from anywhere in the world since unprotected connections to the Internet (or any network topology) leaves the user computer vulnerable to hacker attacks and other Internet threats. Therefore, to provide high degree of protection to the network and network's user, Firewall need to be used.
Firewall provides a barrier between the user computer and the Internet (i.e. it prevents unauthor
... Show MoreFiber-to-the-Home (FTTH) has long been recognized as a technology that provides future proof bandwidth [1], but has generally been too expensive to implement on a wide scale. However, reductions in the cost of electro-optic components and improvements in the handling of fiber optics now make FTTH a cost effective solution in many situations. The transition to FTTH in the access network is also a benefit for both consumers and service providers because it opens up the near limitless capacity of the core long-haul network to the local user. In this paper individual passive optical components, transceivers, and fibers has been put together to form a complete FTTH network. Then the implementation of the under construction Baghdad/Al
... Show MorePV connected systems are worldwide installed because it allows consumer to reduce energy consumption from the electricity grid. This paper presents the results obtained from monitoring a 1.1 kWp. The system was monitored for nine months and all the electricity generated was fed to the fifth floor for physics and renewable energy building 220 V, 50 Hz. Monthly, and daily performance parameters of the PV system are evaluated which include: average generated of system Ah per day, average system efficiency, solar irradiation around these months. The average generated kWh per day was 8 kWh/day, the average solar irradiation per day was 5.6 kWh/m2/day, the average inverter efficiency was 95%, the average modules efficien
... Show More