The current research studies the aesthetic framework for the dialectical development of the functions of the contemporary theater director in an aesthetic approach to the mechanisms of functional overlap between the dramaturgy and direction functions, and scenography and direction, the detection of the controversial structure of that overlap, and what can be summed up in the following question: (what are the aesthetic approaches of the dialectical development in the function of the contemporary theatre director?). The research is determined by a pivotal aim which is (knowing the aesthetic nature of the dialectical development in the functions of the contemporary theater director). The researcher addressed his research in three frameworks: the methodological framework in which the researcher identified the research problem, importance, goal, and limits, then the theoretical framework, which consists of two dimensions: the first dealt with a historical overview of the origins and methods of direction , and the second dimension dealt with the theme of direction dialectics: dialectic of the dramaturgy director, and the scenography director , ending with a set of theoretical indicators. The procedural framework included the researcher's procedures of dropping the indicators, which he concluded from his theoretical framework, on his research sample which he identified as a model for the study. The research concluded with a number of conclusions, the most important of which are:1- The data of contemporary dramaturgy formed an advanced function for the contemporary director, and a directing task to manage the aesthetic awareness according to the direction vision.2- The data of contemporary scenography practice formed one of the advanced functions of the contemporary director, and a directing task through the design of sensory cognitive plans of the scene.
In this work, the calculation of matter density distributions, elastic charge form factors and size radii for halo 11Be, 19C and 11Li nuclei are calculated. Each nuclide under study are divided into two parts; one for core part and the second for halo part. The core part are studied using harmonic-oscillator radial wave functions, while the halo part are studied using the radial wave functions of Woods-Saxon potential. A very good agreement are obtained with experimental data for matter density distributions and available size radii. Besides, the quadrupole moment for 11Li are generated.
In this research, the kinetic studies of four isoenzymes of Asprtate aminotransferase, which partially purified from the urine of chronic renal failure patients were carried out .The four isoenzymes were obeyed Michaelis-Menton's equation and the optimum concentration of their substrate (Aspartic acid) was (166.5x10-3) mole/liter,and their Km values were determined. Four isoenzymesI,II,III,IV have shown an optimum pH at 7.4.The four isoenzymes obeyed Arrhenius equation up to 37º C and their Ea and Q10 constants were determined .
The purpose of my thesis is to synthesis two new bidentate ligands which were used to prepare series of metal complexes by reacting the ligands with (M+2 = Mn, Co, Ni, Cu, Cd and Hg) Succinyl chloride was used as starting material to synthesis two bidentate ligands (L1) and (L2) by reaction it with 4-chloroaniline (L1) and (4-aminoacetophenone) (L2) in dichloromethane as a solvent, that are: (L1) = N1,N4-bis (4-chloro phenyl ) succinamide (L2) =N1,N4-bis(4-acetylphenyl)succinamide The new ligands were characterize by using spectroscopic study (Fourier-transform infrared spectroscopy (FT-IR), electronic spectra ( UV-Vis) ,nuclear magnetic resonance(1H,13C-NMR), Mass spectra
... Show MoreObjective: This in vitro study is aimed to compare and evaluate the cyclic fatigue of four varying NiTi rotary instrumentation systems. Method: In this study, four types of rotary files were used in four groups (10 files for each group), namely, Group A: Wave One Gold; Group B: AF Blue R3; Group C: One Curve; Group D: F6 SkyTaper. These groups were evaluated by a cyclic fatigue apparatus to measure cyclic fatigue resistance within the artificial metallic simulating canal that has a 60 angle of curvature, the curvature radius was 5 mm, whereas the inner diameter of the canal was 1.5 mm. All the files were rotated in artificial canals until they fracture. The resistance to cyclic fatigue was determined by counting the number of cycles to frac
... Show MoreBackground: Visfatin is a novel adipokine that mainly secreted by visceral adipose tissue, had an important role in inflammation and immune system. Creatine Kinase (CK) which is an enzyme that is involved in energy metabolism, found in large amounts in myocardium, brain and skeletal tissues. This study is carried out To evaluate the periodontal health status of the study groups (chronic periodontitis and chronic periodontitis with coronary atherosclerosis) and control groups, to measure the salivary levels of visfatin and Creatine Kinase in these groups and compare between them, and to determine the correlations between salivary visfatin and Creatine Kinase levels with the periodontal parameters in the three groups. Materials and Methods: e
... Show Morepaper
Microwave heating is caused by the ability of the materials to absorb microwave energy and convert it to heat. The aim of this study is to know the difference that will occur when heat treating the high strength aluminum alloys AA7075-T73 in a microwave furnace within different mediums (dry and acidic solution) at different times (30 and 60) minutes, on mechanical properties and fatigue life. The experimental results of microwave furnace heat energy showed that there were variations in the mechanical properties (ultimate stress, yielding stress, fatigue strength, fatigue life and hardness) with the variation in mediums and duration times when compared with samples without treatment. The ultimate stress, yielding stress and fatigue streng
... Show MoreWhile conservative access preparations could increase fracture resistance of endodontically treated teeth, it may influence the shape of the prepared root canal. The aim of this study was to compare the prepared canal transportation and centering ability after continuous rotation or reciprocation instrumentation in teeth accessed through traditional or conservative endodontic cavities by using cone-beam computed tomography (CBCT).
Forty extracted intact, matured, and 2-rooted human maxillary first premolars were selected for this