The design of the interior spaces process the product of intellectual civilization expresses the prevailing thought, discoverers of principles and beliefs through the sheen reflects the present, and generating languages graphical variety caused a different revolution in design mounting structure, and because of the complex nature of the interior spaces were and we have to be a reflection of cultural reality of being a form of cultural expression and true embodiment of scientific developments prevailing for each stage where she was born, the changes occurring in human thought and then extremism and the discrepancy tastes among individuals all communities factors have caused a change in the design structure involving modernization and down towards the contemporary technology and this is what was called search his address and the importance of modernization as a concept evolutionary as well as related concepts down to determine the importance of modern technology as an influence in building structure design, and by clarifying the behaviors that concept to enable the search to identify the research problem by asking the following: Are contemporary technology works as an influence in the formation of structure design interior spaces? The objective of the research: to identify the importance of modern technology as an influence in building structure design. The second chapter included the theoretical framework, which contained a statement of the concept of technology and contemporary concept. This statement, along with the contemporary style of relationship and modernization as well as touched upon some of the concepts put forward by the technology, and technology between the art and the path of civilization. And ensure that the third chapter research procedures in terms of methodology and the research community, and the research sample intentionality, then elected modeling analysis, and finally the fourth quarter included the findings of the search after the analysis process, and then conclusions with suggestions and recommendations.
The temperature control process of electric heating furnace (EHF) systems is a quite difficult and changeable task owing to non-linearity, time delay, time-varying parameters, and the harsh environment of the furnace. In this paper, a robust temperature control scheme for an EHF system is developed using an adaptive active disturbance rejection control (AADRC) technique with a continuous sliding-mode based component. First, a comprehensive dynamic model is established by using convection laws, in which the EHF systems can be characterized as an uncertain second order system. Second, an adaptive extended state observer (AESO) is utilized to estimate the states of the EHF system and total disturbances, in which the observer gains are updated
... Show MoreIn current article an easy and selective method is proposed for spectrophotometric estimation of metoclopramide (MCP) in pharmaceutical preparations using cloud point extraction (CPE) procedure. The method involved reaction between MCP with 1-Naphthol in alkali conditions using Triton X-114 to form a stable dark purple dye. The Beer’s law limit in the range 0.34-9 μg mL-1 of MCP with r =0.9959 (n=3) after optimization. The relative standard deviation (RSD) and percentage recoveries were 0.89 %, and (96.99–104.11%) respectively. As well, using surfactant cloud point extraction as a method to extract MCP was reinforced the extinction coefficient(ε) to 1.7333×105L/mol.cm in surfactant-rich phase. The small volume of organi
... Show MoreThis study evaluates the flexural behavior of ultra-thin (50 mm) one‑way reinforced‑concrete (RC) slabs retrofitted with near‑surface mounted (NSM) carbon‑fiber‑reinforced polymer (CFRP) rods under quasi‑static loading. T300‑grade CFRP rods (≈4 mm diameter) were bonded in pre‑cut 7 mm × 7 mm grooves using a two‑part epoxy. As a proof-of-concept experimental baseline, three simply‑supported specimens (1000 mm × 500 mm × 50 mm) were tested in a six‑point bending configuration (four applied loads + two reactions): two conventional controls and one strengthened slab. A load‑control rate of ~15 kN/min was applied; the controls were cycled twice and the strengthened slab four times. Relative to the average of
... Show MoreThe research aimed to statement, which impact that the development of Iraqi auditing standards in the fight against corruption and to fulfill the reform requirements by conducting a comparative study analysis with a framework proposal to amend the Iraqi Audit directory number statement (6) issued by the Accounting and Auditing Standards Board of the Republic of Iraq dated 08/24/2002 on audit planning and supervision on the basis of the latest versions of international auditing standards in this regard.
The researchers concluded that there is a need to update the standards (evidence) audit accredited in the Republic of Iraq in accordance with international auditing standards to meet the requirements of the report of the external a
... Show MoreCertainly there is a negative impact on development due to corruption in its corruption forms It is administrative and financial as well as direct impact on all sectors Including the health sector, which has seen in Iraq a marked setback in performance and services , The research aims at the possibility of demonstrating the negative effects of financial and administrative corruption on health institutions and Inability to meet health needs The extent to which Regulatory institutions and institutions manage to reduce financial and administrative corruption and ways of dealing with it The phenomenon of financial and administrative corruption is the most serious phenomenon because of its impact on economic growth, which in turn impedes the
... Show MoreThis paper investigated the fatigue life behavior of two composite materials subjected to different times of shot peening (2, 4 and 6 min).The first material prepared from unsaturated polyester with E-glass reinforcement by 33% volume fraction. While, the second one was prepared from unsaturated polyester with aluminum powder by2.5% volume fraction. The experimental results showed that the improvement in endurance limit was obtained (for the first material) at 2, 4 and 6 min shot peening times where the percentage of maximum improvement was 25% at shot peening time of 6 min. While, the endurance limit of the second material decreased at shot peening times of 2, 4 and 6 min where the percentage of maximum reduction was 29 % at shot peenin
... Show MoreNow-a-days the Flexible AC Transmission Systems (FACTS) technology is very effective in improving the power flow along the transmission lines and makes the power system more flexible and controllable. This paper deals with the most robust type of FACTS devices; it’s a Unified Power Flow Controller (UPFC). Many cases have been taken to study how the system behaves in the presence and absence of the UPFC under normal and contingency conditions. The UPFC is a device that can be used to improve the bus voltage, increasing the loadability of the line and reduce the active and reactive power losses in the transmission lines, through controlling the flow of real and reactive power. Both the magnitude and the phase angle of th
... Show More