Abstract
The use of electronic valves is commonly available. yet, the most
common is the techniques of communications as prod casting transmitter that
are used by these valves in addition to their use in communication tools as far
distance telephone, electronic measuring techniques , and others.
In this study, an attempt is endeavored for improving the efficiency of the
vacuum micro- valves(GI-19b) through activating their internal surfaces by the
use of ionic pumping which is used for treating valves which are out of order
(because of sedimentation some materials and oxide on its poles). The
existence of these materials and oxide increase the sum of current leakage
moving in between. The use of ionic pumping method leads to direct high
voltage on the poles since the sum of the current can be largely decreased.
Besides, they are other methods for fixing valves up these valves.
The practical result of measuring current leakage of the prepared valves
proves there is improving of the measured valves; it is noticed that these
valves are far less than these before treatment. This gives a clue of the
positive effect of this method for fixing valves up.
Objective: The descriptive study was used to evaluate nursing staff performance in cardiac care units at teaching
and non teaching hospitals in kirkuk city: A comparative study.
Methodology: A descriptive study was used to evaluate nursing staff performance in cardiac care units. The study
was conducted from December 29th
, 2013 up to the 27th of Apr. 2014. A non-probability (purposive) sample of
(44) nurses who work in cardiac care unit at Azady teaching Hospital and Kirkuk general Hospital was evaluated by
a questionnaire which consisted of two parts; the first part is concerned with the demographic characteristics of
the nurses and the second part concerned Observation check list for evaluation nursing staff Perfo
In the present work the performance of semifluidized bed adsorber was evaluated for removal of phenolic compound from wastewater using commercial activated carbon as adsorbent. P-chlorophenol (4-Chlorophenol) and o-cresol (2-methylphenol) was selected as a phenolic compound for that purpose. The phenols percent removal, in term of breakthrough curves were studied as affected by hydrodynamics limitations which include minimum and maximum semifluidization velocities and packed bed formation in the column by varying various parameters such as inlet liquid superficial velocity (from Uminsf to 8Uminsf m/s), and retaining grid (sometimes referred to as adsorbent loading) to initial static bed height ratio (from 3-4.5). In
... Show MoreSoil improvement has developed as a realistic solution for enhancing soil properties so that structures can be constructed to meet project engineering requirements due to the limited availability of construction land in urban centers. The jet grouting method for soil improvement is a novel geotechnical alternative for problematic soils for which conventional foundation designs cannot provide acceptable and lasting solutions. The paper's methodology was based on constructing pile models using a low-pressure injection laboratory setup built and made locally to simulate the operation of field equipment. The setup design was based on previous research that systematically conducted unconfined compression testing (U.C.Ts.). Th
... Show MoreThe main objective and primary concern to every investor not only to achieve a greater return on his or her investments, but also to create the largest possible value of these investments the, researchers and those interested in the field of investment and financial analysis try to develop standards for performance valuation is guided through the  
... Show MoreThree different distribution modules of silicon solar cells in a panel are used in this study . Each module consists of five identical circular silicon solar cells of radius (5cm) and then the total panel areas are identical. The five solar cells are arranged in the panel in different shapes: circular, triangular and rectangular .The efficiency for these three panel distribution are measured indoor and outdoor. The results show that the efficiency is a function of the cells distribution.
Abstract:
The research aims to achieve defining the concept of environmental quality and associated costs. Studying the impact of environmental quality costs on the performance of economic units. Measuring the relationship between environmental quality and environmental performance of the units. Where the research problem is represented in the weak awareness of some economic units of the importance of environmental quality costs and their impact on evaluating environmental performance, and this leads to neglecting environmental considerations and not improving environmental performance effectively, which negatively affects the en
... Show Moreأستهدفت الدراسة اختبار أثر التوجه السوقي والتزام العاملين على أداء المنظمة المسوقة لخدمات النقل الجوي. حيث تم اختيار شركة الخطوط الجوية الملكية الأردنية كمجال تطبيقي.وقد اعتمدت الدراسة في قياس المتغيرات على مقاييس مختبرة وقد تأكد صحتها وثباتها لقياس المتغيرات في البيئة الحالية. وقد بينت نتائج التحليل الإحصائي الذي استخدمت فيه أساليب إحصائية مختلفة بالاستعانة ببرنامج SPSS))
The electric energy is one of the most important renewable energies used in the world as it is the main source for sustainable development and economic development through its use in (production, transport and distribution), and in Iraq, the electric power sector has suffered from many problems and obstacles, as providing electric current is one of the most prominent difficulties and challenges That successive governments and residents have faced since the early nineties of the last century and are still ongoing, and that Iraq has all the climatic conditions for developing the work of the electricity system from renewable energies such as solar and hydroelectric energy, as well as gas fields that have become a Basic pillar of pow
... Show MoreThis work was conducted to study the coefficient of performance for solar absorption refrigeration by using direct solar energy using aqueous ammonia 0.45 mass fraction (ammonia – water).The experiments were carried out in solar absorption system .The system consisted of solar collector generator (0.25 m × 0.25 m × 0.04m) and condenser cooled by a water bath followed by liquid receiver and evaporator. The results showed that the maximum generator temperature was (92° - 97°) during June 2009, and the minimum evaporator temperature was (5°C - 10°C) for aqua ammonia system.. It was, also, found that the coefficient of performance, cooling ratio and amount of cooling obtainable increased with increasing maximum generator temperature
... Show More