Obesity is a common disease that resulted from over-nutrition in adults and children. It rarely causes damage to the centers of food in the brain. Obesity is defined as an increased body weight from its natural limit which is resulted from the accumulation of excessive amounts of fatty tissue incredibly up to 20% in males, 30 % in females unless this increase is not due to an increase in muscles as in athletes or accumulation of water in the body which is resulted from Mesothelioma or the magnitude of the skeleton.Obesity is the increase of the total average of fat in the body compared to other tissues, which causes an increasing body weight, thereby increasing body mass. The fatty child has an increase in the stored fatty layer under the skin, and increased weight 20%more than the normal weight of other children in the same age and height.
This thesis focuses on identifying showing the relationship between obesity and some of the variables. Moreover, the thesis reflects the importance of maintaining the ideal weight of the child and his role in the growth and health. The evidence shows that children who suffer from obesity are more likely to become fat adults, so they are exposed to increased risk of serious health problems. Hence, protecting children from obesity and treating them is possible through changing lifestyle, improving the child's nutrition system, and urging him to exercise to improve their health at the present time and in the future.
Therefore, the thesis aims: to detect significant differences in obesity for kindergarten children depending on certain variables through the testing hypothesis as followed: Statistically there are no significant differences in obesity with kindergarten children that are attributable to the following variables:
(A)Sex variable.
(B) The sequence of the child in the family..
(C) Dietary habits of the family.
To achieve the objectives of this study, 300 children were selected as samples, 166 males and 134 females. One of the most important tools that were used is:
1 - an electronic device for measuring weight.
2 - Length measuring tape.
3 - Measurement of body mass index (BMI)..
The researcher used in data statistical analysis:
(1) One way Anova.
(2) The T- test for two independent samples: Independent Samples Test.
(3) The real bilateral correlation coefficient (Point Bay Cyril).
The most important results that have been reached:
(1) That females suffer from obesity more than males because the body mass index of females is greater than the body mass index (BMI) for males.
(2) There is no statistically significant difference between the averages of body mass index (BMI) scores for kindergarten children due to the variable of the sequence of the child within his brothers.
(3) There is no statistically significant difference between the averages of body mass index (BMI) scores for obese kindergarten children that is attributed to behavioral tendencies variable of the child.
The use of essential services in modern constructions, such pipes, and ducts, became important, placing these pipes and ducts underneath the soffit of the beam. They made a ceiling sandwich, and that causes to reduce the height of the floor, so the presence of the opening in the beam saves the height of the floor. In this paper, the investigation of the beam response of reinforced concrete simply supported rectangle beams with square web openings is presented, including a number of the web openings (two, four, and eight), in addition to its use in strengthening the member at the openings (when the beam is planned before casting, internal deformation steel bar is used, and in case of the opening is existing in the b
... Show MoreConcrete is widely used in construction materials since early 1800's. It has been known that concrete is weak in tension, so it requires some addition materials to have ductile behavior and enhance its tensile strength and strain capacity to improve their uses. In this study reactive powder concrete (RPC) was used with steel fiber by using different types of cement; (Ordinary Portland cement (OPC) and/or Portland- Limestone cement (PLC)) with three types of mixtures (OPC at the first mix, 50 % OPC and 50 % PLC at the second mix and PLC at the third mix). The behavior of RPC with steel fibers on compressive strength and tensile strength of concrete with different ages of curing (7, 14, 28 and 60) days and shrinkage have been studied. The clo
... Show MoreDengke Naniura is a traditional food from Sumatera Utara, Indonesia, that is produced through fermenting process, and this food is believed to contain high probiotics. The objective of the current research is to determine the potential of LAB as a probiotic that has been obtained from Dengke Naniura. Dengke Naniura was traditionally prepared from Cyprinus carpio. Four LABs have been successfully isolated from Dengke Naniura, such as D7DA3, D7B3, D7DBF and D7DN3. Those four LAB isolates were identified as Lactobacillus sp. This result has been confirmed by the non-spore forming bacterium, non-motile, and Gram-positive. Also, it has been supported by biochemical test, for the example Voges Proskauer, catalase test, Methyl
... Show MoreIn this paper, an exact stiffness matrix and fixed-end load vector for nonprismatic beams having parabolic varying depth are derived. The principle of strain energy is used in the derivation of the stiffness matrix.
The effect of both shear deformation and the coupling between axial force and the bending moment are considered in the derivation of stiffness matrix. The fixed-end load vector for elements under uniformly distributed or concentrated loads is also derived. The correctness of the derived matrices is verified by numerical examples. It is found that the coupling effect between axial force and bending moment is significant for elements having axial end restraint. It was found that the decrease in bending moment was
in the
the use of diffrent concectration of Na and Mg ions were shown to causes in increase in the bindings at oncentration
This study aimed to investigate the influence of longitudinal steel embedded tubes located at the center of the column cross-section on the behavior of reinforced concrete (RC) columns. The experimental program consisted of 8 testing pin-ended square sectional columns of 150×150 mm, having a total height of 1400 mm, subjected to eccentric load. The considered variables were the steel square tube sizes of 25, 51 and 68 mm side dimensions and the load eccentricity (50 and 150) mm. RC columns were concealed steel tubes with hollow ratios of 3%, 12% and 20% depending on tube sizes used. The experimental results indicated an improvement in the overall behavior of eccentric columns when steel embedded tubes are used. The maximum gain in
... Show MoreA long-span Prestressed Concrete Hunched Beam with Multi-Quadrilateral Opening has been developed as an alternative to steel structural elements. An experimental program was created and evaluated utilizing a single mid-span monotonic static load on simply supported beams, which included six beams with openings and the solid control beam without openings, to investigate the performance of such beams. The number and height of the quadrilateral openings are the variables to consider. According to test results, the presence of openings in the prestressed concrete hunched beam with multi-quadrilateral opening did not considerably affect their ultimate load capacity with respect to a contro
Test results of six half-scale reinforced concrete flat plates connections with an opening in the vicinity of the column are reported. The test specimens represent a portion of a slab bounded by the lines of contraflexure around the column. The tests were designed to study the effect of openings on the punching shear behavior of the slab-column connections. The test parameters were the location and the size of the openings. One specimen had no opening and the remaining five had various arrangements of openings around the column. All specimens were cast with normal density concrete of approximately 30 MPa compressive strength. The openings in the specimens were square, with the sides parallel to the sides of the column. Three sizes of ope
... Show MoreIn this research, the efficiency of low-cost unmodified wool fibers were used to remove zinc ion from industrial wastewater. Removal of zinc ion was achieved at 99.52% by using simple wool column. The experiment was carried out under varying conditions of (2h) contact time, metal ion concentration (50mg/l), wool fibers quantity to treated water (70g/l), pH(7) & acid concentration (0.05M). The aim of this method is to use a high sensitive, available & cheep natural material which applied successfully for industrial wastewater& synthetic water, where zinc ion concentration was reduced from (14.6mg/l) to (0.07mg/l) & consequently the hazardous effect of contamination was minimized.