This study aimed at identity baying the difficulties which face public basic school
principals in jar ash governorate in editing formal letters and correspondence and means of
debating with these problems to collect data the researchers developed a question air were
established the population of the study which represents its sample consisted of 129 principals
65 males and 64 females
The results of the study revealed that the principals face difficulties in office and file
management in preparing plans and reports and writing formal letters and answering them
saved recommendations were presented among which were organizing training sessions and
workshops to train the principals on how to dead with there problems.
Keywords: difficulties formal correspondence letter editing
New Fe(II),Co(II),Ni(II),Cu(II) and Zn(II) Schiff base complexes which have the molar ratio 2:1 metal to ligand of the general formula [M2( L) X4] (where L=bis(2-methyl furfuraldene)-4-4`-methylene bis(cyclo-hexylamine) ) were prepared by the reaction of the metal salts with the ligand of Schiff base derived from the condensation of 2:1 molar ratio of 2-acetyl furan and 4-4`-methylene bis (cyclohexylamine). The complexes were characterized by elemental analysis using atomic absorption spectrophotometer ,molar conductance measurements, infrared, electronic spectra,and magnetic susceptibility measurement. These studies revealed binuclear omplexes. The metal(II) ion in these complexes have four coordination sites giving the most ex
... Show MoreThe present study focuses on synthesizing solar selective absorber thin films, combining nanostructured, binary transition metal spinel features and a composite oxide of Co and Ni. Single-layered designs of crystalline spinel-type oxides using a facile, easy and relatively cost-effective wet chemical spray pyrolysis method were prepared with a crystalline structure of MxCo3−xO4. The role of the annealing temperature on the solar selective performance of nickel-cobalt oxide thin films (∼725 ± 20 nm thick) was investigated. XRD analysis confirmed the formation of high crystalline quality thin films with a crystallite si
In this work Laser wireless video communication system using intensity modualtion direct
detection IM/DD over a 1 km range between transmitter and receiver is experimentally investigated and
demonstrated. Beam expander and beam collimeter were implemented to collimete laser beam at the
transmitter and focus this beam at the receiver respectively. The results show that IM/DD communication
sysatem using laser diode is quite attractive for transmitting video signal. In this work signal to noise
ratio (S/N) higher than 20 dB is achieved in this work.
In this study, an experimental investigation had conducted for six high strength laced reinforced concrete one-way slabs to discover the behavior of laced structural members after being exposed to fire flame (high temperature). Self-compacted concrete (SCC) had used to achieve easy casting and high strength concrete. All the adopted specimens were identical in their compressive strength of ( , geometric layout 2000 750 150 mm and reinforcement specifics except those of lacing steel content, three ratios of laced steel reinforcement of (0.0021, 0.0040 and 0.0060) were adopted. Three specimens were fired with a steady state temperature of for two hours duration and then after the specimens were cooled suddenly by spraying water. The
... Show MoreObjective(s): To determine the impact of instructional intervention program upon psychological health status for
women who undergo chemotherapy after mastectomy
Methodology: The sample consisted of (100) women, (50) considered as study group, and another (50) the control
group. A pre test was done for both groups (study and control), and then the study samples were exposed to an
instructional intervention and three-dimensional post tests and the length of time between each test 21 days in
the Institute and Hospital of Radiation and Nuclear Medicine. The questionnaire composed of three parts, first,
demographic information; include (age, educational level, type of family, occupation, marital status, and adequacy
of mo
In this study, the effect of fire flame on the punching shear strength of steel fiber reinforced concrete flat plates was experimentally investigated using nine half-scale specimens with dimensions of 1500×1500 mm and a total thickness of 100 mm. The main investigated variables comprised the steel fiber volume fraction 0, 1, and 1.5% and the burning steady state temperature 500 and 600 °C. The specimens were divided into three groups, each group consists of three specimens. The specimens in the first group were tested with no fire effect to be the reference specimens, while the others of the second and third groups were tested after being exposed to fire-flame effect. The adopted characteristics of the fire test were; (one hour) b
... Show MoreThe current study includes (130) T2DM patients (group P) [51 males and 79 females with an ages range (35 to 55) and ages mean 49.89 years], they are sub-grouped into three categories according to their HbA1c value. patients with HbA1c less than 7 are considered as good controlled diabetic patients (30 patients) (group P1), while patients with HbA1c between 7 and 8 are considered as medium controlled diabetic patients (40 patients) (group P2), and the patient whom their HbA1c more than 8 are considered as uncontrolled diabetic patients (50 patients) (group P3). The patients group results are compared to control healthy subjects (35 subjects) (group C) [14 males and 21 Females with age range 45.51 years] matched for age, gender and BMI wer
... Show MoreThis study investigates the implementation of Taguchi design in the estimation of minimum corrosion rate of mild-steel in cooling tower that uses saline solution of different concentration. The experiments were set on the basis of Taguchi’s L16 orthogonal array. The runs were carried out under different condition such as inlet concentration of saline solution, temperature, and flowrate. The Signal-to- Noise ratio and ANOVA analysis were used to define the impact of cooling tower working conditions on the corrosion rate. A regression had been modelled and optimized to identify the optimum level for the working parameters that had been founded to be 13%NaCl, 35ᴼC, and 1 l/min. Also a confirmation run to establish the p
... Show More