Reading strategies are of interest for what they reveal about the ways readers manage their interaction with written texts and how these strategies are related to text understanding, acquisition ,storage ,and retrieval of information .In EFL comprehension lessons, the students try to work out interpretations of the meaning related to the written word through the usage of different comprehension strategies. Yet, there are moments where the participants in the classroom fail to reach a successful understanding of the passage read despite the guidance of the teacher. The present research aims at investigating and identifying moments of comprehension failure and reasons behind them .It also aims at specifying the different strategies used in terms of type and number of occurrences. It is hypothesized that some students in EFL classrooms fail to understand parts of written texts because they do not use any kind of strategy at particular stages of the comprehension process. The samples selected for the research are the two sections of first year students in the Department of English language, College of Arts and Letters in Cihan University. Each section included 30 students who study comprehension as a basic course ,through their first academic year, in an average of 3 hours per week. Eight comprehension lessons have been recorded and the passages discussed during these lessons , were chosen from the students' text book ‘’Practice & Progress’’ by L.G. Alexander, 1967. The research provides a brief overview of the studies related to the process of reading comprehension .It also illustrates the ways many linguists identified the factors contributing to understanding written texts during the previous years. This is followed by mentioning the general strategies that are used by learners of the English language with explanation of their meaning and role in comprehending written texts. Section two presents the analysis of the recorded lessons. Though the discussions of eight passages were recorded, only three of them were included in the research due to shortage of space. Moments of comprehension failure are specified by the letters (CF) with reference to the reason. Types of strategies used during the lessons are identified as well. Finally, it is concluded that the students sometimes fail to grasp the meaning of some lines or parts of a text because they don't use certain strategies .The analysis of the lessons also shows that the strategies that are mostly used by the students, in their attempt to understand what they read, are: using prior knowledge, inferring meaning, questioning, visualizing, and determining importance which are used in sequence and number of occurrences that differ from one text to another .On the other hand, strategies like synthesizing and summarizing are hardly ever used in some texts and never used in others. The research also illustrates the significant role of the teacher that contributes to the students’ critical thinking and understanding of the written text
Aryl hydrocarbon receptor (AhR) is a ligand-activated transcription factor that regulates T cell function. The aim of this study was to investigate the effects of AhR ligands, 2,3,7,8-Tetrachlorodibenzo-p-dioxin (TCDD), and 6-Formylindolo[3,2-b]carbazole (FICZ), on gut-associated microbiota and T cell responses during delayed-type hypersensitivity (DTH) reaction induced by methylated bovine serum albumin (mBSA) in a mouse model. Mice with DTH showed significant changes in gut microbiota including an increased abundance of
Sensibly highlighting the hidden structures of many real-world networks has attracted growing interest and triggered a vast array of techniques on what is called nowadays community detection (CD) problem. Non-deterministic metaheuristics are proved to competitively transcending the limits of the counterpart deterministic heuristics in solving community detection problem. Despite the increasing interest, most of the existing metaheuristic based community detection (MCD) algorithms reflect one traditional language. Generally, they tend to explicitly project some features of real communities into different definitions of single or multi-objective optimization functions. The design of other operators, however, remains canonical lacking any inte
... Show MoreIn this work, effects of using different evaporative cooling pads (ECPs) on the energetic and exergetic efficiency of a direct evaporative air cooler (DEAC) have been theoretically and experimentally investigated. Three types of ECPs were used, i.e., honeycomb cellulose cooler pad (HCCP), shading-cloth cooler pad (SCCP), and aspen wood wool cooler pad (AWWCP). For SCCP and AWWCP, a 3-cm pad thickness was used, while for the HCCP, three different values of pad thickness were used, i.e., 3, 5, and 7 cm. Tests were carried out using air velocities of 8, 14, and 19 m/s, measured at the DEAC outlet. Engineering equation solver (EES) used for performing the required calculations of the various parameters affecting the thermal performance of the D
... Show MoreThe pretreatment process can be considered one of the important processes in wastewater treatment, especially coagulation process to decrease the strength of many pollutants. This paper focused on using powdered date seeds as natural coagulant in addition to chemical coagulants (alum and ferric chloride) to find the optimum dosage of each coagulant that makes efficient removal of turbidity and chemical oxygen demand (COD) from domestic wastewater as a pretreatment process, then finding the optimum combined dosages of date seeds with alum, date seeds with ferric chloride that make efficient removal for both pollutants. Concerning turbidity, the optimum dosage for date seeds, alum and ferric chloride were 40 mg/l (79%), 70
... Show MoreAn experimental and theoretical works were carried out to model the wire condenser in the domestic refrigerator by calculating the heat transfer coefficient and pressure drop and finding the optimum performance. The two methods were used for calculation, zone method, and an integral method. The work was conducted by using two wire condensers with equal length but different in tube diameters, two refrigerants, R-134a and R-600a, and two different compressors matching the refrigerant type. In the experimental work, the optimum charge was found for the refrigerator according to ASHRAE recommendation. Then, the tests were done at 32˚C ambient temperature in a closed room with dimension (2m*2m*3m). The results showed that th
... Show More