ABSTRACT Background: This study measured the effects of three parameters pH value, length of immersion and type of archwire on metal ions released from orthodontic appliances. Materials and Methods: Ninety maxillary halves simulated fixed orthodontic appliances that were immersed in artificial saliva of different pH values (6.75, 5 and 3.5) during 28 day period. Three types of archwires were used: stainless steel, nickel titanium and thermal activated nickel titanium. The quantity of nickel and chromium ions was determined with the use of atomic force spectrophotometer while iron ions by spectrophotometer. Each orthodontic set was weighted two times, before the ligation and immersion in the artificial saliva and after 28 days at the end of immersion period using analytic balance device. Results: The release different metal ions was observed: nickel (Ni), chromium (Cr) and iron (Fe)). Statistically analysis of variance (ANOVA) and t-test were used. Results showed that (1) the appliances released measurable quantities ofall ions examined; (2) the change in pH had a very strong effect on the release of ions; (3) the release of ions was dependent on wire composition, but it was not proportionalto the content of metal in the wire and (4) orthodontic samples showed decreases in the weight at the end of the study. Conclusion: Levels of released ions are sufficient to cause delayed allergic reactions. This must be taken into account when type of archwire is selected, especially in patients with hypersensitivityor compromised oral hygiene.
The pure and Sb doped GeSe thin films have been prepared by thermal flash evaporation technique. Both the structural and optical measurement were carried out for as deposited and annealed films at different annealing temperatures.XRD spectra revealed that the all films have one significant broad amorphous peak except for pure GeSe thin film which annealed at 573 K, it has sharp peak belong to orthorhombic structure nearly at 2θ=33o . The results of the optical studies showed that the optical transition is direct and indirect allowed. The energy gap in general increased with increasing annealing temperature and decreased with increase the ratio of Sb dopant. The optical parameters such as refractive index, extinction coefficient and r
... Show MoreThe pure and Sb doped GeSe thin films have been prepared by thermal flash evaporation technique. Both the structural and optical measurement were carried out for as deposited and annealed films at different annealing temperatures.XRD spectra revealed that the all films have one significant broad amorphous peak except for pure GeSe thin film which annealed at 573 K, it has sharp peak belong to orthorhombic structure nearly at 2θ=33o. The results of the optical studies showed that the optical transition is direct and indirect allowed. The energy gap in general increased with increasing annealing temperature and decreased with increase the ratio of Sb dopant. The optical parameters such as refractive index, extinction coefficient and real and
... Show MoreThis work presents a completely new develop an analyzer, named NAG-5SX1-1D-SSP, that is simple, accurate, reproducible, and affordable for the determination of cefotaxime sodium (CFS) in both pure and pharmaceutical drugs. The analyzer was designed according to flow injection analysis, and conducted to turbidimetric measurements. Ammonium cerium nitrate was utilized as a precipitating agent. After optimizing the conditions, the analysis system exhibited a linear range of 0.008-27 mmol. L-1 (n=29), with a limit of detection of 439.3 ng/sample, a limit of quantification of 0.4805 mg/sample, and a correlation coefficient of 0.9988. The repeatability of the responses was assessed by performing six successive injections of CFS at concentra
... Show MoreGlassy carbon electrode (GCE) was modified with carbon nanotubes CNT and C60 by attachment and solution evaporation techniques, respectively. CNT/Li+/GCE and C60/Li+/GCE were prepared by modifying CNT/GCE and C60/GCE in Li+ solution via cyclic voltammetry (CV) potential cycling. The sensing characteristics of the modified film electrodes, demonstrated in this study for interference of Mn2+ in different heavy metals ion esp. Hg2+, Cd2+ and Cu2+. The interfering effect was investigated that exert positive interference on the redox peaks of Mn2+. The modification of GCE with nano materials and Li+ act an enhancement for the redox current peaks to observe the effect of interference for Mn2+ in 1:1 ratio with different heavy metals ion.
Background: Cardiopulmonary resuscitation (CPR) is a technique or procedure that combined chest compression and rescue breathing to maintain enough circulation that prevents brain damage until other essential steps are taken to control the main cause of cardiac and respiratory arrest. The health care personnel should be qualified in the performing of cardiopulmonary resuscitation (CPR) to improve the survival rate of the victims. Therefore; it is necessary to use new methods for learning [1]. Objectives: the study aims to compare the effectiveness of self-instructional teaching strategy and traditional teaching approach on student’s knowledge toward cardiopulmonary resuscitation. Methods: A randomized comparative trial (RCT) design was ca
... Show MoreBackground: Wound healing is a complex dynamical interaction between various cell types, the extracellular matrix, cytokines, and growth factors. osteoponetin is a substance that acts as an anti-inflammatory. Aims of study: The study was designed to identify the role of local exogenous applications of osteopontin on wound healing (in cheek skin). Materials and methods: Thirty adult male albino rats weighting an average of (250-300gm) used in this study, incisional wounds were made in the skin of the cheek of rat and they were divided into the following groups: A-Control group: 15 rats treated with 1µ l of normal saline B-Experimental groups: 15 rats treated with topical application of 1µl osteopontin. The scarification of animals we
... Show More