Background: Mouthwashes used widely as ancillary to mechanical oral hygiene methods. Little information provided about the effect of mouthwashes on ions released from orthodontic brackets. Therefore, the present study has been established to evaluate the effect of different mouthwashes on the corrosion resistance and the biocompatibility of two brands of brackets. Materials and Methods: Eighty premolar stainless steel brackets were used (40 brackets from each brand). They were subdivided into four subgroups (n=10) according to immersion media (deionized distilled water, Corsodyl, Listerine and Silca herb mouthwashes). Each bracket was stored in a closely packed glass tube filled with 15ml of the immersion media and incubated for 45 days at 37ºC. Then chromium, nickel, copper and manganese ions release were measured using Atomic absorption spectrophotometer, while iron ions release were measured by using Iron kit and spectrophotometer. For statistical analysis, t-test, analysis of variance (ANOVA) and least significant difference (LSD) were used. Results: The results revealed that the ions released from Dentaurum brackets were significantly higher than that from OrthoTechnology brackets in all type of immersion media except for Chromium ions in Corsodyl mouthwash. The release of copper and chromium ions was significantly higher in Listerine and Corsodyl mouthwashes than in deionized distilled water being related to the pH of the immersion media. While, the release of iron, nickel and manganese ions in the three mouthwashes was comparable to that in deionized distilled water. Conclusions: The amounts of released ions were below toxic levels and did not exceed the daily dietary intake, but it may be recommended to avoid prolonged use of Listerine and Corsodyl mouthwashes in patients allergic to chromium.
Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness
... Show MoreFarmers keep trying to avoid using chemical fertilizer without losing high yield. A field experiment was conducted in the fields of Agriculture College, University of Baghdad during winter seasons of 2015 and 2016 to investigate the response of three bread wheat cultivars (Ibaa99, Abu-Ghraib3 and Buhooth22) to the frequency of spraying with biofertilizer (EM-1) (one time at tillering stage, twice at tillering and stem elongation stages and three times at tillering, stem elongation and booting stages) in addition to the control (without spraying), to the increase of grain yield. Randomized complete block design (RCBD), in split plots arrangement and four replications, was used. Spraying treatments were placed as main plots and cultivars as s
... Show MoreSome auditors may think that the audit process ends with discovering misstatements and informing management about them, while the discovery of misstatements may be classified by some as the first step in the phase of separating these distortions, as the auditor should collect these misstatements, evaluate them and detail them into misstatements involving errors or misstatements involving fraud Then evaluating it to material or immaterial according to what was stated in the international auditing standards and directing management to amend the essential ones. The importance of this research lies in identifying the concept of distortions and their types, identifying the method of evaluating distortions into substantial and non-essent
... Show MoreBackground: Prophylaxis methods are used to mechanically remove plaque and stain from tooth surfaces; such methods give rise to loss of superficial structure and roughen the surface of composites as a result of their abrasive action. This study was done to assess the effect of three polishing systems on surface texture of new anterior composites after storage in artificial saliva. Materials and methods: A total of 40 Giomer and Tetric®N-Ceram composite discs of 12 mm internal diameter and 3mm height were prepared using a specially designed cylindrical mold and were stored in artificial saliva for one month and then samples were divided into four groups according to surface treatment: Group A (control group):10 specimens received no surfa
... Show MoreThe objective of this study was to evaluate the impact two doses of Menaquinones-7 on hepatotoxicity induced by doxorubicin in rats. Sixty adult rats of both sexes were used in this study; the animals were randomly enrolled into six groups of 10 animals each. Group I: negative control (rats administered distilled water); Group II: Menaquinones-7 at a dose of 16 µg/kg; Group III: Menaquinones-7 at a dose of 48 µg/kg; Group IV: positive control (Doxorubicin 15 mg/kg); Group V: Menaquinones-7 at a dose of 16 µg/kg administered prior to a single dose of Doxorubicin 15 mg/kg; Group VI: Menaquinones-7 at a dose of 48 µg/kg administered prior to a single dose of Doxorubicin 15 mg/kg. On day twelve of the study, blood was
... Show MoreA study of the singlet and triplet states of two electron systems in the first excited state was performed using a simple quantum mechanical model, which assigns the 1s,and 2s orbital with two different variational parameters. Our results agree with a high level calculation used by Snow and Bills.
An acidic environment causes surface changes of resin composites. Filler particlesize and filler distribution also have a direct effect on these surface changes. This invitro study evaluated the influence of Pepsi Cola drink on the surface roughness ofComposan LCM and Composan Ceram over time. Sixteen disc shaped specimens(10mm diameter, 2mm thickness) of each resin composite were fabricated, therebyforming two groups (n= 8). Surface roughness (Ra) was analyzed after 24 hrs beforeexposure to beverage. The specimens were submitted to a five minutes immersion inPepsi Cola three times daily interrupted by immersion in deionized distilled water (37C˚). Surface roughness measurements were done at 10, 30, and 60 days intervals. Datawere
... Show MoreThe major aim of this research is study the effect of the type of lightweight aggregate (Porcelinite and Thermostone), type and ratio of the pozzolanic material(SF and HRM) and the use of different ratios of w/cm ratio(0.32 and 0.35) on the properties of SCLWC in the fresh and hardened state. SF and HRM are used in three percentage 5%,10%, and 15% as a partial replacement by weight of
cement for all types of SCLWC. The requirements of self-compatibility for SCC are fulfilled by using the high performance superplasticizer (G51) at 1.2liter per 100 kg of cement. The values of air dry density and compressive strength at age of 28 days within the limits of structural lightweight concrete. The air dry density and compressive strength at a
Dental casts come into direct contact with impression materials and other items that are contaminated by saliva and blood from a patient's mouth, leaving the casts susceptible to cross-contamination. The disinfectant solutions of the impression materials cause various adverse reactions. Therefore, disinfection of dental casts may be effective in preventing cross infection. This study was carried out to evaluate the surface hardness, dimensional accuracy, reproduction of details and surface porosity of type III, type IV and type IV extra hard dental stone after immersion in and spray by using SOLO and Sodium hypochlorite disinfectant solutions. Materials and methods: 240 Stone samples were prepared in rubber rings, A total of 60 test block w
... Show More