Background: With the start of the current century, increased the interest in the role of the adipose tissue derived substances that named adipokines in the inflammatory diseases of the human being including the inflammatory periodontal disease, but scientific evidences were not clearly demonstrate the association between these adipokines and periodontal pathologies. Materials and Methods: Forty two subjects male only with normal body mass index were selected for the study with an age ranged (30-39 years). Samples were divided into three groups of 14 subjects in each group based on clinical periodontal parameters; clinically healthy gingiva (group I), gingivitis group (group II) and chronic periodontitis patients group (group III), from whom saliva and serum samples were collected for estimating the levels of leptin and resistin using Enzyme-Linked Immuno Sorbent Assay (ELISA). Results: The results showed that the serum level of leptin and resistin were significantly higher in chronic periodontitis patient (9.81 ng/ml, 6.55 ng/ml) respectively as compared to gingivitis and healthy control groups (leptin; 8.10 ng/ml, ng/ml, resistin; 5.85 ng/ml, 5.45 ng/ml) respectively. On the other hand the level of leptin in saliva of patients with chronic periodontitis (0.17 ng/ml) was significantly lower than that of its salivary levels in gingivitis and healthy control groups (0.21 ng/ml, 0.29 ng/ml) respectively. Whereas, salivary resistin levels was significantly higher in chronic periodontitis patient(14.45 ng/ml) when compared to the gingivitis group (11.59 ng/ml) and the health control group (6.43 ng/ml). Conclusions: Concomitant raise in serum leptin, serum resistin and salivary resistin, while a sensible reduction in salivary leptin with conversion from periodontal health state to periodontal disease state. These finding may draw a suggestion on the role of leptin and resistin in the relation between periodontal disease and the systemic health since the increase in their level were associated with a various systemic pathologies.
The widespread use of the Internet of things (IoT) in different aspects of an individual’s life like banking, wireless intelligent devices and smartphones has led to new security and performance challenges under restricted resources. The Elliptic Curve Digital Signature Algorithm (ECDSA) is the most suitable choice for the environments due to the smaller size of the encryption key and changeable security related parameters. However, major performance metrics such as area, power, latency and throughput are still customisable and based on the design requirements of the device.
The present paper puts forward an enhancement for the throughput performance metric by p
... Show MoreIn the current work, the mixing ratios ( 𝛿 ) of gamma transitions were calculated from energy levels in the isotopes neodymium 60𝑁𝑎 142−150 populated in the 60Nd 142− 150 (n, n ˊγ) 60Nd 142− 150 using the 𝑎2 ratio method. We used the experimental coefficient (𝑎2 ) for two γ-transitions from the initial state itself, the statistical tensor 𝜌2(𝐽𝑖), associated with factor 𝑎2 , would be the same for the two transitions. The results obtained are in good agreement or within the experimental error with -those previously published. And existing contradictions resulting from inaccuracies in the empirical results of previous work. The current results confirm that the , 𝑎2 − method is used to calculate th
... Show MoreAromatic Schiff-bases are known to have antibacterial activity, but most of these compounds are sparingly soluble in water. The present work describes the synthesis of new Schiff-bases derived from branched aminosugars. Treatment of 3-Amino-3-Cyano-3-Deoxy-1,2:5,6-Di-O-Isopropylene-α-D-Allofuranose (1) with the aldehydes (2) under reflux in methanol afforded the Schiff-bases (3) in good yields. The new Schiff-bases were in accord with their NMR, IR spectral data and elemental analysis.
In this work, the synergistic effect of chlorinated rubber (additive I),with zeolite 3A (additive II), zeolite 4A (additive III), and zeolite 5A (additive IV) in (1:1) weight percentage, on the flammability for unsaturated polyester resin was studied in the weight ratios for (3,7,10,13&15%) by preparing films of (130×130×3) mm in diameters. Three standard test methods used to measure were the flame retardation which are; ASTM: D-2863, ASTM: D- 635& ASTM: D-3014. Results obtained from these tests indicated that all of the additives were effective additive IV has the highest efficiency as a flame retardant.
Mn2O3 was coated onto reduced titania nanotubes by reverse pulse electrodeposition, showing smooth and homogenous deposits without covering the opening of the nanotubes.
a laser ablation Q-switched Nd: YAG laser with a wave-length of 355 nm at a variety of laser pulse energies (E) and deposited on porous silicon (PS). Optical emission spectrometer was used to diagnosed medium air to study gold plasma characteristics and prepared Au nanoparticles. The laser pulse energy influence has been studied on the plasma characteristics in air. The data showed the emergence of the ionic (Au II) spectral emission lines in the gold plasma emission spectrum. XRD has been utilized to examine structural characteristics. Moreover, AFM results 37.2 nm as the mean value of the diameter that is coordinated in a shape similar to the rod that appears for Au NPs, in addition to that, TEM has been an indication of the fact that syn
... Show Morenovel spectrofluorimetric flow injection analysis (FIA) method was developed for the selective quantification of ascorbic acid via fluorescence quenching of serotonin hydrochloride. The system employs a custom-designed photometric array comprising 16 irradiation sources arranged in a dual-axis matrix—eight aligned horizontally and eight orthogonally, enabling multi-angle excitation and enhanced spectral resolution. Fluorescence signals were captured using a twin-pair solar cell detector, offering high sensitivity and minimal optical interference. The method exhibited a linear calibration range of 0.1–30 limit of detection (LOD) of 0.025 μ μ g/mL with a correlation coefficient (r mol /L, equivalent to 4.403 * 10 4 μ 2 ) of 0.9966, a g
... Show MoreBackground: The gene encoding a disintegrin and metalloproteinase domain 33 (ADAM33) is known to be associated with asthma in different ethnic groups. In Iraq, among the Arab ethnic background, this association has not yet been highlighted. Methods: One hundred and ninety-two asthmatics were examined; 118 males and 74 females (mean age 38.23 ± 9.13 years). The control group was 183; 110 males and the rest were females. The SNP of rs2280091 A/G (T1) was studied here to determine adam33 genotyping status using polymerase chain reaction–restriction fragment length polymorphism (PCR–RFLP). The level of total IgE was measured using enzyme-linked immunosorbent assay (ELISA). Results: Significant differences (p = 0.004) in the frequencies of
... Show MoreAbstract: The increased interest in developing new photonic devices that can support high data rates, high sensitivity and fast processing capabilities for all optical communications, motivates a pre stage pulse compressor research. The pre-stage research was based on cascading single mode fiber and polarization maintaining fiber to get pulse compression with compression factor of 1.105. The demand for obtaining more précised photonic devices; this work experimentally studied the behavior of Polarization maintaining fiber PMF that is sandwiched between two cascaded singe mode fiber SMF and fiber Bragg gratings FBG. Therefore; the introduced interferometer performed hybrid interference of both Mach-Zehnder
... Show MoreThis study presents a rapid, sensitive, and straightforward approach to measure chlorpheniramine maleate (CPM) by using turbidity CFIA. The method involves CPM reacting with sodium nitroprusside (Nitropress) to produce a pale white precipitate. The NAG-SSP-5S1D analyzer was used to measure turbidity at 0°–180° angle to detect the attenuation of incident light as a result of collision on the surfaces of the precipitate particles. The linear range of CPM measurements was between 0.008 and 11 m.mol/L, with correlation coefficient of 0.9983 and R2% = 99.65. The limit of detection was determined to be 0.0328 µg/sample from the lowest concentration in the calibration curve, and the repeatability of the method (RSD%) was less than 0.4% (n = 6
... Show More