Preferred Language
Articles
/
jbcd-953
Thickness of Buccal Bone at Various Sites of the Mandible and Its Clinical Significance in MonocorticalScrews Placement Using Multi-Slice Computed Tomography
...Show More Authors

Background:Open reduction and internal fixation (ORIF) of using miniplates and screws is the treatment of choice of mandibular fractures. It is important to know both: the region where the bone providesafirm anchorage, andthe topography of the dental apices and inferior alveolar nerve to avoiddamaging them when inserting the screw. The aim of this study is to determine the thickness of buccal cortical plate and that of buccal bone at the parasymphysis and mandibular body, thereby determining the area that provide afirm anchorage and the maximum length of mono-cortical screws that can be safely placed in these regions without injuring the tooth roots or mandibular nerve. Materials and Methods:The sample of the present study was 110 Iraqi subjects (77 males & 33 females) aged (18-35) years old who admitted to Computed Tomography scan unit in AL-Sadr Teaching Hospital in Al-Najaf city to get Computed Tomographic examination of facial bones. The conventional sections of CT (axial, coronal) used to do the measurements and dental planning analysis also used. The thickness of buccal cortical plate and the thickness of buccal bone were measured at the level of root apex of (canine, first premolar, second premolar) and at the level ofroot apex and inferior alveolar canal in mesial and distal root of first and second molar. Results:There was no statistical significant difference in buccal cortical plate and buccal bone thickness between age and gender at most measured sites. Using of 4mm screw is safe in distal root region of 2nd molar at the level of apex and that of inferior alveolar canal for both males and females. Moving slightly forward in position to the mesial root of 2nd molar 1mm will be lost from safety margin, while making only the 3mm screw is safe. For the remaining anterior positions only the minimum screw length of 2 mm is safe. Conclusions:Thickness of buccal cortical plate and buccal bone in various sites could be measured precisely using Multislice Computed tomography which can guide surgeons in selecting the proper screw length without causing injury to tooth apex or inferior alveolar nerve.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Nov 21 2022
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn: 2789-3219 )
Nanotechnology at the Molecular Level
...Show More Authors

Materials with external dimensions of one or more nanometers are referred to as nanomaterials. These structures result from a number of manufacturing processes. They are used in many industries, including pharmaceuticals, which is the most significant one. Numerous variables, including size, shape, surface morphology, crystallinity, solubility, etc., affect physical properties. While new physical and chemical processes are being created constantly, the biological method is the ideal strategy for synthesizing nanoparticles since it is straightforward, safe, and economical. Different kinds of nanoparticles can be metabolically synthesized by a wide variety of biological sources, including plants, bacteria, fungi, and yeast. There are

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Thu Apr 18 2019
Journal Name
Al-kindy College Medical Journal
Clinical and Refractive Outcomes of Toric Phakic Implantable Collamer lens Implantat for correction of myopic astigmatism
...Show More Authors

Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber.

Objective: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. in  Eye Specialty Private Hospital, Baghdad, Iraq.

Type of the Study: a prospective non randomize intervention study.

Methods: 60 eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design).Mean spherical refraction was ₋11.32 diopter

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 16 2021
Journal Name
Kufa Medical Journal
Clinical and Refractive Outcomes of Toric Phakic Implantable Collamer Lens Implantation for correction of myopic astigmatism
...Show More Authors

Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber. Aim: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. Methods: Sixty eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design) in the Eye Specialty Private Hospital, Baghdad, Iraq were studied. The mean spherical refraction was -11.32±3.17 diopter (D) with a range of -6.00 to -18.00 D and a mean cylinder of -2.61±1.16 with range of -1.00 to -5.50 D. The outcome measures that evaluat

... Show More
View Publication
Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of Osseointegration of Dental Implants Prepared by Piezosurgery (Clinical Study)
...Show More Authors

ABSTRACT Background: Piezosurgery device is a system developed recently to overcome the limitation of the traditional surgical technique in implant site preparation, which use the principle of ultrasonic microvibrations to create precise & selective cut in bone in harmony with the surrounding tissues. The aim of this study was to evaluate the outcomes of implants inserted by ultrasonic implant site preparation protocol (UISP) using piezosurgery device, regarding the survival rate, stability and other related factors, at 16 weeks postoperative follow up period. Materials and Methods: A total of (24) patients, (6) males and (18) females, aged between (19-51) years old, contributed in this study receiving a total of (42) implants, all of these

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Dec 24 2022
Journal Name
Research Journal Of Pharmacy And Technology
Biological Study of protease produced by clinical isolates of Staphylococcus aureus
...Show More Authors

The bacterial isolates were obtained from Al-Kindi Hospital were diagnosed by the Vitek-2 system and re confirm by 16srRNA gene as S. aurous, the results were shown 20 isolates (66.7%) out of 30 isolates were positive to protease production. All bacterial isolates (100%) were sensitive to Gentamicin and Levofloxacin. but resistant (100%) to aztreonam. The best temperature for enzyme production from bacteria was 37 °C, and the best pH for enzyme production was 7. Partial purification of the bacterial enzyme (protease) was carried out using short steps included ammonium sulfate 65% saturation, ion exchange using DEAE- cellulose column and then applied on gel filtration chromatography using Sephadex G-200 column. The enzymatic activit

... Show More
View Publication
Scopus (22)
Scopus Crossref
Publication Date
Wed Oct 18 2023
Journal Name
Ieee Access
A New Imputation Technique Based a Multi-Spike Neural Network to Handle Missing Data in the Internet of Things Network (IoT)
...Show More Authors

View Publication
Scopus (10)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Analytical Chemistry
A Spectrophotometric Method for Tetracycline Determination in its Bulk Powder and Pharmaceutical Formulations Using Flow Injection and Batch Procedures: a Comparative Study
...Show More Authors

A reliable and environmental analytical method was developed for the direct determination of tetracycline using flow injection analysis (FIA) and batch procedures with spectrophotometric detection. The developed method is based on the reaction between a chromogenic reagent (vanadium (III) solution) and tetracycline at room temperature and in a neutral medium, resulting in the formation of an intense brown product that shows maximum absorption at 395 nm. The analytical conditions were improved by the application of experimental design. The proposed method was successfully used to analyze samples of commercial medications and verified throughout the concentration ranges of 25–250 and 3–25 µg/mL for both FIA and batch procedures, respecti

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sat Jun 30 2012
Journal Name
Al-kindy College Medical Journal
The Necessity of Teaching Diabetic Patients the Correct way of Insulin Administration: A Clinical Trial to Improve Glycemic Control
...Show More Authors

Background: It is important to achieve good glycemic control to avoid long-term diabetic complications. It has been largely debated about the role of correct way of insulin administration to get the desired glycemic control.
Objective: To evaluate the effect of teaching diabetic patients who are on insulin therapy the correct way of injecting insulin and its effect on glycemic control.
Methods: A non randomized clinical trial with 820 diabetic patients on insulin therapy on whom A1 c estimation was performed before and after three months of teaching them the right injection technique.
Results : Sixty seven patients (8.17%) had A1 c 6.5% before they were enrolled in the study while the majority (753 patents, 91.82%) had A1 c 6.5%

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 30 2012
Journal Name
Al-kindy College Medical Journal
The Necessity of Teaching Diabetic Patients the Correct way of Insulin Administration: A Clinical Trial to Improve Glycemic Control
...Show More Authors

Background: It is important to achieve good glycemic control to avoid long-term diabetic complications. It has been largely debated about the role of correct way of insulin administration to get the desired glycemic control.
Objective: To evaluate the effect of teaching diabetic patients who are on insulin therapy the correct way of injecting insulin and its effect on glycemic control.
Methods: A non randomized clinical trial with 820 diabetic patients on insulin therapy on whom A1 c estimation was performed before and after three months of teaching them the right injection technique.
Results : Sixty seven patients (8.17%) had A1 c 6.5% before they were enrolled in the study while the majority (753 patents, 91.82%) had A1 c 6.5%

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Educational And Psychological Researches
The organizational performance of the kindergarten teachers and its relation with the educational environment of kindergartener
...Show More Authors

The research aims at identifying the organizational performance of the kindergarten teachers and defines the educational environment of kindergarten children. To achieve the objectives of the research, the researcher adopted the organizational performance scale for (Saadi, 2016), which was applied to kindergarten teachers. The scale consists of (43) paragraphs, and has good reliability and validity, as the coefficient of reliability (84.0) in a retest method, and (87.0) using the formula Alpha Kronbach. Additionally, the researcher adopted the educational environment scale for (Radam, 2015); the scale consists of (66) paragraphs, and it enjoys a good reliability and validity, as the coefficient of reliability (89.0) method of reliability

... Show More
View Publication Preview PDF