Preferred Language
Articles
/
jbcd-953
Thickness of Buccal Bone at Various Sites of the Mandible and Its Clinical Significance in MonocorticalScrews Placement Using Multi-Slice Computed Tomography
...Show More Authors

Background:Open reduction and internal fixation (ORIF) of using miniplates and screws is the treatment of choice of mandibular fractures. It is important to know both: the region where the bone providesafirm anchorage, andthe topography of the dental apices and inferior alveolar nerve to avoiddamaging them when inserting the screw. The aim of this study is to determine the thickness of buccal cortical plate and that of buccal bone at the parasymphysis and mandibular body, thereby determining the area that provide afirm anchorage and the maximum length of mono-cortical screws that can be safely placed in these regions without injuring the tooth roots or mandibular nerve. Materials and Methods:The sample of the present study was 110 Iraqi subjects (77 males & 33 females) aged (18-35) years old who admitted to Computed Tomography scan unit in AL-Sadr Teaching Hospital in Al-Najaf city to get Computed Tomographic examination of facial bones. The conventional sections of CT (axial, coronal) used to do the measurements and dental planning analysis also used. The thickness of buccal cortical plate and the thickness of buccal bone were measured at the level of root apex of (canine, first premolar, second premolar) and at the level ofroot apex and inferior alveolar canal in mesial and distal root of first and second molar. Results:There was no statistical significant difference in buccal cortical plate and buccal bone thickness between age and gender at most measured sites. Using of 4mm screw is safe in distal root region of 2nd molar at the level of apex and that of inferior alveolar canal for both males and females. Moving slightly forward in position to the mesial root of 2nd molar 1mm will be lost from safety margin, while making only the 3mm screw is safe. For the remaining anterior positions only the minimum screw length of 2 mm is safe. Conclusions:Thickness of buccal cortical plate and buccal bone in various sites could be measured precisely using Multislice Computed tomography which can guide surgeons in selecting the proper screw length without causing injury to tooth apex or inferior alveolar nerve.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri May 01 2020
Journal Name
International Journal Of Psychosocial Rehabilitation
The Psychological Pollution And Its Role In The Effectiveness Of The Administrative Performance Of International Stadiums Staff (Baghdad, Arbil, Basrah)
...Show More Authors

MT Abed, ALSG Irhayyim, TH Rija, International Journal of Psychosocial Rehabilitation, 2020 - Cited by 1

View Publication
Publication Date
Thu Dec 01 2022
Journal Name
Civil And Environmental Engineering
Performance of Prestressed Concrete Hunched Beams with Multi-Quadrilaterals Openings
...Show More Authors
Abstract<p>A long-span Prestressed Concrete Hunched Beam with Multi-Quadrilateral Opening has been developed as an alternative to steel structural elements. An experimental program was created and evaluated utilizing a single mid-span monotonic static load on simply supported beams, which included six beams with openings and the solid control beam without openings, to investigate the performance of such beams. The number and height of the quadrilateral openings are the variables to consider. According to test results, the presence of openings in the prestressed concrete hunched beam with multi-quadrilateral opening did not considerably affect their ultimate load capacity with respect to a contro</p> ... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Dec 01 2015
Journal Name
Journal Of Engineering
Improved Automatic Registration Adjustment of Multi-source Remote Sensing Datasets
...Show More Authors

Registration techniques are still considered challenging tasks to remote sensing users, especially after enormous increase in the volume of remotely sensed data being acquired by an ever-growing number of earth observation sensors. This surge in use mandates the development of accurate and robust registration procedures that can handle these data with varying geometric and radiometric properties. This paper aims to develop the traditional registration scenarios to reduce discrepancies between registered datasets in two dimensions (2D) space for remote sensing images. This is achieved by designing a computer program written in Visual Basic language following two main stages: The first stage is a traditional registration process by de

... Show More
Crossref (1)
Crossref
Publication Date
Wed Jun 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Formulation of Multi-Purpose Grease for Use under Severe Conditions
...Show More Authors

View Publication Preview PDF
Publication Date
Tue Dec 01 2015
Journal Name
Journal Of Engineering
Improved Automatic Registration Adjustment of Multi-source Remote Sensing Datasets
...Show More Authors

Registration techniques are still considered challenging tasks to remote sensing users, especially after enormous increase in the volume of remotely sensed data being acquired by an ever-growing number of earth observation sensors. This surge in use mandates the development of accurate and robust registration procedures that can handle these data with varying geometric and radiometric properties. This paper aims to develop the traditional registration scenarios to reduce discrepancies between registered datasets in two dimensions (2D) space for remote sensing images. This is achieved by designing a computer program written in Visual Basic language following two main stages: The first stage is a traditional registration p

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 30 2021
Journal Name
Journal Of Economics And Administrative Sciences
HRA and its Impact on Employees Performance: A Field Research in the Ministry of Education
...Show More Authors

          The research aims to determine the impact of Human Resources Accounting (HRA) on employee’s performance. The research’s problem was embodied in the lack of interest in HRA, which was reflected on the performance of employees in the Ministry of Education; the research adopted the descriptive-analytical approach, and the research community included the directors of departments and people at the headquarters of the Ministry of Education. The sample size was (224) individuals from the total community of 533. The questionnaire was adopted as the main tool for collecting data and information, as well as the interviews that were conducted by the researcher. In order to analyze t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Oct 01 2019
Journal Name
Journal Of Economics And Administrative Sciences
Stock Exchange and its Impact on Economic Development In the Kingdom of Saudi Arabia (KSA)
...Show More Authors

this research paper aims at measuring and analyzing the influence of the stock exchange on the economic development in the Kingdom. This is done through comparing the Gross Domestic Product (GDP) as a changeable factor affiliated with some independent variables in the KSA stock exchange. These variables are (All Share Index {TASI}, Market Value, Trade Volume Index, number of companies and number of shares). The study covers the period from 2003 to 2017 and adapts the measuring method in analyzing this relation using the Multiple Linear Regression (Stepwise) and (SPSS). The study affirmed the validity of the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 04 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Design and Implement an EC-Application Based on Multi Database Environment
...Show More Authors

 The vast majority of EC applications are the web-based deployed in 3-tire Server-Client environment, the data within such application often resides within several heterogeneous data sources. Building a single application that can access each data sources can be a matter of challenging; this paper concerns with developing a software program that runs transparently against heterogeneous environment for an EC-application.
 

View Publication Preview PDF
Publication Date
Sun Sep 15 2024
Journal Name
Journal Of Baghdad College Of Dentistry
The reliability of insertion torque as an indicator for primary stability in immediate dental implant: A prospective clinical study
...Show More Authors

Background: The primary stability of the dental implant is a crucial factor determining the ability to initiate temporary implant-supported prosthesis and for subsequent successful osseointegration, especially in the maxillary non-molar sites. This study assessed the reliability of the insertion torque of dental implants by relating it to the implant stability quotient values measured by the Osstell device. Material and methods: This study included healthy, non-smoker patients with no history of diabetes or other metabolic, or debilitating diseases that may affect bone healing, having non-restorable fractured teeth and retained roots in the maxillary non-molar sites. Primary dental implant stability was evaluated using a torque ratc

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Jun 01 2009
Journal Name
Journal Of Economics And Administrative Sciences
Using the Box Jenkins models to predict Iraq's cement production and to demonstrate its adequacy under future construction projects
...Show More Authors

تعد صناعة السمنت في العراق من اقدم الصناعات الحديثة واكثرها تطورا وتقدما ومن اقواها تاثيرا في الاقتصاد القومي. واذ توفر في صناعة السمنت العراقي كافة المستلزمات الناجحة من حيث توفر المواد الاولية والخبرات الفنية والتقنية واسواق ثابتة وراسخة محليا وعالميا فقد كان من المفروض ان يتم التوسع في هذه الصناعة، وان التخطيط لهذه الصناعة امرا ضروريا خاصة وان مادة السمنت هي احدى اهم المواد الرئيسة التي يؤثر توفره

... Show More
View Publication Preview PDF
Crossref