Background:Open reduction and internal fixation (ORIF) of using miniplates and screws is the treatment of choice of mandibular fractures. It is important to know both: the region where the bone providesafirm anchorage, andthe topography of the dental apices and inferior alveolar nerve to avoiddamaging them when inserting the screw. The aim of this study is to determine the thickness of buccal cortical plate and that of buccal bone at the parasymphysis and mandibular body, thereby determining the area that provide afirm anchorage and the maximum length of mono-cortical screws that can be safely placed in these regions without injuring the tooth roots or mandibular nerve. Materials and Methods:The sample of the present study was 110 Iraqi subjects (77 males & 33 females) aged (18-35) years old who admitted to Computed Tomography scan unit in AL-Sadr Teaching Hospital in Al-Najaf city to get Computed Tomographic examination of facial bones. The conventional sections of CT (axial, coronal) used to do the measurements and dental planning analysis also used. The thickness of buccal cortical plate and the thickness of buccal bone were measured at the level of root apex of (canine, first premolar, second premolar) and at the level ofroot apex and inferior alveolar canal in mesial and distal root of first and second molar. Results:There was no statistical significant difference in buccal cortical plate and buccal bone thickness between age and gender at most measured sites. Using of 4mm screw is safe in distal root region of 2nd molar at the level of apex and that of inferior alveolar canal for both males and females. Moving slightly forward in position to the mesial root of 2nd molar 1mm will be lost from safety margin, while making only the 3mm screw is safe. For the remaining anterior positions only the minimum screw length of 2 mm is safe. Conclusions:Thickness of buccal cortical plate and buccal bone in various sites could be measured precisely using Multislice Computed tomography which can guide surgeons in selecting the proper screw length without causing injury to tooth apex or inferior alveolar nerve.
The purpose of present study is to evaluate the effect of co-administration of curcumin (CUR) at various doses on the pharmacokinetic (PK) profile of tacrolimus (TAC), a CYP 3A4 substrate in healthy male rabbits. Healthy male rabbits (n=18) were employed in an in vivo, parallel-randomized study. Three groups of rabbits were selected and separated: The rabbits in the first group (control group) received 1 mg/kg TAC orally. Blood samples (1.5-2 mL) were drawn from rabbits' ear marginal veins at the following time frames: 15.0, 30.0, 45.0, 60.0, 90.0, 120.0, 150.0, 180.0 and 300 minutes after TAC administration post dosing and analyzed by using a TAC chemiluminescent enzyme immunoassay (CLIA) detection kit. In the second and third gro
... Show MoreObjective: The aim of this study was to compare the marginal microleakage between bulk-fill, preheated bulk-fill, and bulk-fill flowable composite resins above and below cemento-enamel junction (CEJ) using micro-computed tomography. Methods: Sixty freshly extracted premolar teeth were prepared with a slot shaped cavities of a total of 120 Class II: 3mm (bucco-lingual), 2mm (mesio-distal) with mesial-gingival margin located 1mm coronal to CEJ, and distal gingival margin located 1mm apical to the CEJ. The samples were randomly divided into two main groups according to the restorative material (Tetric EvoCeram and 3M Filtek), and each group was further sub-divided into three subgroups according to the consistency (bulk fill, preheated bulk fil
... Show MoreBackground/purpose: Dental implantology involves different treatments that have been used in conjunction with dental implant surgery to increase implant stability and bone regeneration process. Photobiomodulation( PBM) can be one of these techniques. The objective of this study was to evaluate the bone density around implants. Materials and methods: in this study, 10 individuals had 20 implants inserted in the posterior of their mandibles. each patient received two implants the left side served as the control whereas the right side served as the study group with a diode laser (same patients). measurements were made for each implant. Measurements were obtained using cone-
... Show MoreBackground: Simultaneous and staged guided bone regeneration (GBR) is one of the several surgical techniques that have been developed in the past two decades to regenerate bone and thus to allow implant placement in compromised sites (fenestration and dehiscence). It is a surgical procedure that consists of the placement of a cell-occlusive physical barrier between the connective tissue and the alveolar bone defect. The treatment concept advocates that regeneration of osseous defects is predictably attainable via the application of occlusive membranes, which mechanically exclude non-osteogenic cell populations from the surrounding soft tissues, thereby allowing osteogenic cell populations originating from the parent bone to inhabi
... Show MoreThe History of Multi Parties and its Effect on Political System in India
The study of the language through the prophetic curriculum in general and the semantics in particular through the books of Professor Abdul Salam Yassin, may God have mercy on him and the most distinctive linguistic phenomena, and then study semantics and the most prominent methods that reveal the emotions dominated by this study to indicate the semantics of religious terms In this research we try to dive into the sea of significance to know the relationship between the words and their connotations, and to monitor aspects of semantic development, although we have left non-essential words in order to avoid lengthening. N or three and sometimes Aguetsarna on one example we thought it was enough to clarify the meaning.
The behaviour of the electrical conductivity (σ) and the activation energies (Ea1, Ea2) have been investigated on a-InAs thin films as a function of thickness (250,350,450,550,650) nm, before and after heat treatment. The films were annealed at (373, 423, 473) K for one hour. The films contain two types of transport mechanisms, and the electrical conductivity (σ) increases whereas the activation energy (Ea) would decrease as the films thickness increases.
The dynamic thermomechanical properties, sealing ability, and voids formation of an experimental obturation hydroxyapatite-reinforced polyethylene (HA/PE) composite/carrier system were investigated and compared with those of a commercial system [GuttaCore (GC)]. The HA/PE system was specifically designed using a melt-extrusion process. The viscoelastic properties of HA/PE were determined using a dynamic thermomechanical analyser. Human single-rooted teeth were endodontically instrumented and obturated using HA/PE or GC systems, and then sealing ability was assessed using a fluid filtration system. In addition, micro-computed tomography (μCT) was used to quantify apparent voids within the root-canal space. The data were statistically analys
... Show MoreThirteen isolates were collected from various clinical sources during the periodfrom 22/10/2017 to 22/12/2017. All the isolates were diagnosed based on the microscopic and biochemical propertiesby Vitek-2 Compact system. All isolates formed biofilm 100%, with 30% of isolatesbiofilm produced strongly and 70% on medium. The results of the present study have shown the presence of Curli fimbriae genes in E. cloacae bacteria from cases of urinary tract infections, infected patient with blood bacteremia and inflammation of wounds. Curli fimbriae is considered to be an important factor in the virulence of E.cloacae bacteria, which plays an important role in adhering and combining cells on solid surfaces to form the biofilmand helps in the adhesion
... Show MoreAim: The reduction in the amount of marginal bone is the most important demand for the long term success of dental implants. This prospective clinical study was aimed to investigate the marginal bone loss of early loaded SLActive implants with different dimensions and surgical approaches. Materials and methods Fifteen patients aged from 18 to 60 years were divided into 2 groups (flapped and flapless approach) that underwent delayed implant placement protocol with SLActive implants. The marginal bone level was estimated by cone-beam computed tomography during three different periods: preoperatively, 8 weeks after surgery and 24 weeks after loading of the prosthesis. Results: The mean value of marginal bone level was not significantly chan
... Show More