Preferred Language
Articles
/
jbcd-952
Validity of 3D Reconstructed Computed Tomographic Image in Using Craniometrical Measurements of the Skull for Sex Differentiation (An Iraqi Study)
...Show More Authors

Background: The skull offers a high resistance of adverse environmental conditions over time, resulting in the greater stability of the dimorphic features as compared to other skeletal bony pieces. Sex determination of human skeletal considered an initial step in its identification. The present study is undertaken to evaluate the validity of 3D reconstructed computed tomographic images in sex differentiation by using craniometrical measurements at various parts of the skull. Materials and Method: 3D reconstructed computed tomographic scanning of 100 Iraqi subject, (50 males and 50 females) were analyzed with their age range from20-70 years old. Craniometrical linear measurements were located and marked on both side of the 3D skull images. Results: For the all parameters measured for sexes the mean value for Male had significantly greater than females with (p value < 0.001). A receiver operating characteristic curves was obtained for each variable to observe their overall performance in sex determination. The area of mastoid triangle was found the best variable in sex differentiation (ROC area =0.97 for unilateral skull measurements and 0.98 for bilateral measurements).while EU-EU was found to be the least one. Conclusion: 3D reconstructed Computed tomography scanning is a good diagnostic method for analyzing the craniometrical measurements of sex determination. sex differentiation for isolated part of the skull when only the fragmentary crania is available, could be achieved and the highest accuracy in sex determination can be obtained whether part or complete skull available.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jun 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Prevalence and localization of the posterior superior alveolar artery in relation to the floor of the maxillary sinus and alveolar crest among sample of Iraqis using computed tomography
...Show More Authors

Background: Posterior superior alveolar artery (PSAA) is branch of the maxillary artery. It usually supplies the lateral wall of the sinus and overlying membrane. Evaluation and awareness of the anatomy of maxillary sinus before surgery is crucial to avoid surgical complications. The aim of this study is to examine the prevalence, location of the (PSAA) in relation to the floor of the maxillary sinus and alveolar crest using computerized tomography (CT) scans. Materials and Methods: This study included 180 Iraqi subjects (99 males and 81 females) with age more than 16 years old. CT scans for (right and left) Maxillary sinuses were done for each patient. The information obtained was assessed in a coronal multi planar reconstructions images (

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jun 01 2017
Journal Name
International Journal Of Applied Engineering Research
A Proposed Method for Generating a Private Key Using Digital Color Image Features
...Show More Authors

In this paper, the goal of proposed method is to protect data against different types of attacks by unauthorized parties. The basic idea of proposed method is generating a private key from a specific features of digital color image such as color (Red, Green and Blue); the generating process of private key from colors of digital color image performed via the computing process of color frequencies for blue color of an image then computing the maximum frequency of blue color, multiplying it by its number and adding process will performed to produce a generated key. After that the private key is generated, must be converting it into the binary representation form. The generated key is extracted from blue color of keyed image then we selects a c

... Show More
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Photoacoustic Imaging for Tumor Detection: An in vitro Simulation Study
...Show More Authors

Photoacoustic is a unique imaging method that combines the absorption contrast of light or radio frequency waves with ultrasound resolution. When the deposition of this energy is sufficiently short, a thermo-elastic expansion takes place whereby acoustic waves are generated. These waves can be recorded and stored to construct an image. This work presents experimental procedure of laser photoacoustic two dimensional imaging to detect tumor embedded within normal tissue. The experimental work is accomplished using phantoms that are sandwiched from fish heart or blood sac (simulating a tumor) 1-14mm mean diameter embedded within chicken breast to simulate a real tissue. Nd: YAG laser of 1.064μm and 532nm wavelengths, 10ns pulse duration, 4

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 24 2025
Journal Name
Al–bahith Al–a'alami
SOCIAL RESPONSIBILITY FOR THE EMPLOYMENT OF WOMAN IN SUSTAINABLE DEVELOPMENT DECLARATIONS: (An Analytical Study of Road Advertising in Baghdad)
...Show More Authors

Woman is the first target of social advertising, because most of these advertisements are primarily belong to them. This paper which is entitled "Social Responsibility for the Employment of Woman in Sustainable Development Declarations, An Analytical Study of Road Advertising in Baghdad" focuses on the use of woman in advertising. This aspect shows that some people see that advertisement is a mirror to what’s found in society such as woman’s behaviors in her everyday life and so on, while other people see that as long as the public wants those advertisings, they are free to choose what they prefer. They think that the shameful advertisements are natural and unavoidable. These vie

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Acquired Error in using Antibiotic for Surgery Patients in Iraqi Hospitals
...Show More Authors

The use of antibiotics (AB) in surgery focused in either treating established infection or to prevent suspected post-operative infection. Inappropriate use of antibiotic for treatment of patients with common infections is a major problem worldwide, with great implications with regards to cost of treatment and development of resistance to the antimicrobial agent. Moreover, antibiotics may often be dispensed without a clear clinical indication. This study was conducted to estimate the medication errors in using antibiotic for surgery patients which may effect their wound healing. A 260 patients with clean-contaminated and contaminated surgery were included from two teaching hospitals, 160 patient from Medical city hospital and 100 fro

... Show More
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Acquired Error in using Antibiotic for Surgery Patients in Iraqi Hospitals
...Show More Authors

The use of antibiotics (AB) in surgery focused in either treating established infection or to prevent suspected post-operative infection. Inappropriate use of antibiotic for treatment of patients with common infections is a major problem worldwide, with great implications with regards to cost of treatment and development of resistance to the antimicrobial agent. Moreover, antibiotics may often be dispensed without a clear clinical indication. This study was conducted to estimate the medication errors in using antibiotic for surgery patients which may effect their wound healing. A 260 patients with clean-contaminated and contaminated surgery were included from two teaching hospitals, 160 patient from Medical city hospital and 100 from Al-

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Thu Apr 24 2025
Journal Name
Journal Of Baghdad College Of Dentistry
A study to compare the efficiency of different instrumentation systems for cleaning oval-shaped root canals (An in vitro study)
...Show More Authors

Background: Proper cleaning and shaping of the whole root canal space have been recognized as a real challenge, particularly in oval-shaped canals.This in vitro study was conducted to evaluate and compare the efficiency of different instrumentation systems in removing of dentin debris at three thirds of oval-shaped root canals and to compare the percentage of remaining dentin debris among the three thirds for each instrumentation system. Materials and methods: Fifty freshly extracted human mandibular molars with single straight oval-shaped distal root canals were randomly divided into five groups of ten teeth each. Group One: instrumentation with ProTaper Universal hand instruments, Group Two: instrumentation with ProTaper Universal rotary

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 01 2024
Journal Name
Journal Of Engineering
Evaluating the Knowledge for Integrating RM and VM Using BIM in the Iraqi Construction Sector
...Show More Authors

The construction industry plays a crucial role in the countries' economy, especially in the developed country. This point encourages the concerned institution to use new techniques and integrate many techniques and methods to maximize the benefits. The main objective of this research is to evaluate the use of risk management, value management, and building information modeling in the Iraqi construction industry. The evaluation process aims at two objectives. The direct objective was to evaluate the knowledge in risk management (RM), value management (VM), and building information modeling (BIM). The indirect objective was to support the participants with information related to the main items mentioned. The questionnaire

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jan 25 2021
Journal Name
Journal Of Craniofacial Surgery
Cone Beam Computed Tomography Evaluation of the Morphological Variation and Width in Mandibular Condyle
...Show More Authors

View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Spectroscopic measurements of the electron temperature in low pressure microwave 2.45 GHz argon plasma
...Show More Authors

The main goal of this work is to obtain the plasma electron temperature Te by optical emission spectroscopy of low pressure microwave argon plasma, as a function of working pressure and microwave power. A plasma system was designed and constructed in our laboratory using a magnetron of domestic microwave oven with power 800W without any commercial part. The applied voltage on the magnetron electrical circuit is changed for the purpose of obtaining the variable values of the microwave power. The spectral detection is performed with a spectrometer of wavelength range (200−1000nm). The working pressure and magnetron applied voltage were 0.3-3.0mbar and 180-240V, respectively. Two methods had been applied to estimate the electron temperatu

... Show More
View Publication Preview PDF
Crossref (1)
Crossref