Background: An accurate adaptation of the crown to the finish line is essential to minimize cement dissolution and to preserve periodontium in fixed partial denture cases. An accurate adaptation of crown is possible only when preparation details are captured adequately in the impression and transferred to cast. For these reasons, gingival displacement is necessary to capture subgingival preparation details.The aim of the present study is to measure in vivo the horizontal displacement of the gingival sulcus obtained by using three new cordless retraction materials (Magic Foam Cord®, Racegel and Astringent Retraction Paste) in comparison to medicated retraction cord. Materials and method: Thirty-two patients requiring porcelain fused to metal fixed partial denture for replacement of a missing maxillary posterior tooth (either one of thepremolars or the first molar). The patients are randomly divided into four groups of eight patients each according to the type of gingival retraction material used as follows: Group I: Medicated retraction cord (racemic epinephrine hydrochloride 0.3 ± 0.2 mg per inch of cord, #00), Group II: Magic Foam Cord® (expanding polyvinyl siloxane), Group III: Racegel (25% aluminum chloride gel) and Group IV: Astringent Retraction Paste (15% aluminum chloride paste). Three depth orientation grooves were prepared in the buccal and palatal surfaces of a maxillary premolar parallel with the long axis of the tooth, extending from the middle third to the gingival third with the level of the free gingiva using a flat-ended diamond fissure bur. Impression of the gingival sulcus was then made using monophase polyether impression material (Impregum™ Penta™ Soft, 3M ESPE, Germany), before and after gingival retraction with either of the aforementioned gingival retraction materials. The sulcus width, before and after gingival retraction was measured on the master cast (in µm), after its sectioning longitudinally bucco-palatally at the middle of the prepared grooves using a rotary diamond disc. The measurement carried out by using digital microscope (Dino-Lite)at a magnification of 230X. The horizontal gingival displacement (the distance from the end of each prepared groove to the crest of the gingiva) measured by subtracting the gingival sulcus width after retraction from that before retraction. Results: The findings of the present study showed that the highest mean of horizontal gingival displacement is recorded by Group IV (Astringent Retraction Paste) (250.7900 µm), whereas the lowest mean of horizontal gingival displacement is recorded by Group III (Racegel) (78.0988 µm). One-way ANOVA test showed statistically highly significant differences among groups (p< 0.01). Least Significant Difference test (LSD test) was also used to make multiple comparisons among groups and revealed a statistically highly significant difference between each two groups (p< 0.01). Conclusion: The two new gingival retraction pastes (Astringent Retraction Paste and Magic Foam Cord®) could be used for gingival retraction as alternatives to medicated retraction cord. They offer advantages of simplified placement technique and shorter application time with greater gingival retraction. Meanwhile, the use of Racegel alone is not recommended for gingival retraction since it provides the least gingival displacement.
Objective: In order to evaluate the effect of different typed of Separating Medium on the roughness of the fitted
tissue surface of acrylic denture base.
Methodology: Chosen three types of separating medium (Group A Tin foil), (Group B Detery Isolant),(Group C
Cold Mould Seal),used 30 samples of hot cure acrylic resin ,10 samples for each group, after complete curing of
these samples , Profilometer device was used to measure the surface roughness of each sample in all groups.
Results: Using One Way ANOVA Test and LSD test, the results were highly significant in differences among all
groups. Although (Group A) showing lest roughness, (Group B) showing a satisfactory result of roughness, While
(Group C) Showing the hig
Background: The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate the tensile forces of selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. Materials and Methods: The study sample includes 120 wires with three types of retainer wires (3 braided strands\ Orthotechnology, 8 braided strands\ G&H Orthodontics, 6 coaxial strands\ Orthoclassic wires), two types of adhesive (flowable\ Orthotechnology, non flowable\ G&H O
... Show MoreBackground: Esthetic correction represents one of the clinical conditions that required the use of laminate veneers in premolars region. Aim of the study: The purpose of this study was to evaluate the fracture strength of the laminate veneers in maxillary first premolars, fabricated from either composite (direct and indirect techniques) or ceramic CAD/CAM blocks. Materials and Methods: Fifty sound human maxillary premolar teeth were used in this in vitro study. Teeth were divided randomly into one control group and four experimental groups of ten teeth each; Group A: Restored with direct composite veneer (Filtek Z250 XT), Group B: Restored with indirect composite veneers (Filtek Z250 XT), Group C: Restored with lithium disilicate ceramic CA
... Show MoreIn this research, the electrical characteristics of glow discharge plasma were studied. Glow discharge plasma generated in a home-made DC magnetron sputtering system, and a DC-power supply of high voltage as input to the discharge electrodes were both utilized. The distance between two electrodes is 4cm. The gas used to produce plasma is argon gas which flows inside the chamber at a rate of 40 sccm. The influence of work function for different target materials (gold, copper, and silver), - 5cm in diameter and around 1mm thickness - different working pressures, and different applied voltages on electrical characteristics (discharge current, discharge potential, and Paschen’s curve) were studied. The results showed that the discharge cur
... Show MoreBackground: Errors of horizontal condylar inclinations and Bennett angles had largely affected the articulation of teeth and the pathways of cusps. The aim of this study was to estimate and compare between the horizontal condylar (protrusive) angles and Bennett angles of full mouth rehabilitation patients using two different articulator systems. Materials and Methods: Protrusive angles and Bennett angles of 50 adult males and females Iraqi TMD-free full mouth rehabilitation patients were estimated by using two different articulator systems. Arbitrary hinge axis location followed by protrusive angles and Bennett angles, estimation was done by a semiadjustable articulator system. A fully adjustable articulator system was utilized to locate th
... Show MoreBackground: The desire for an attractive appearing fixed orthodontic appliance fueled the use of ceramic brackets and clear accessories. Elastics are one of the most versatile materials available to orthodontists so studying their effect on the esthetic appearance is important. This an in vivo study, conducted to evaluate the effect of exposing stretched clear elastomeric ligatures to the oral environment from four different companies (OrthoTechnology, Morelli, Ortho Organizer, and Ormco). Materials and Methods: A total of 240 elastomeric modules were examined, 60 modules from each brand. Each of the 60 patients enrolled in the study, received 4 elastomeric modules on the 4 lower incisors, one from each brand. The specimens were placed on t
... Show MoreABSTRACT Background: One of the methods used in the treatment of maxillofacial fracture is intermaxillary fixation(IMF), the most common type is the Erich arch bar with interdental wiring. This study was conducted to investigate the impact of intermaxillary fixation on gingival health condition among a group of patients with facial fracture in relation to salivary physical properties. Materials and methods: Thirty patients with an age range of (17-37) years old with facial fractures and indicated for IMF. Plaque index and gingival index (Loe, 1967) were used to assess both of them before application and after removal of IMF. Unstimulated saliva sample collection was carried out under standardized conditions according to Navazesh and Kum
... Show More