Background: The main aim of the present study is to qualify and quantify voids formation of root canals obturated with GuttaCore (GC) and experimental Hydroxyapatite polyethylene (HA/PE) as new carrier-based root canal fillings by using micro computed tomography scan. Materials and methods: In the present study, eight straight single-rooted human permanent premolar teeth are selected and disinfected, then stored in distilled water. The teeth decoronated leaving a root length of 12mm each. The root canals instrumented by using crown down technique and the apical diameter of the root canal prepared to a size # 30/0.04 for achieving standardized measurements. A 5mL of 17% EDTA used to remove the smear layer followed by 5mL of 2.5% NaOCl and rinsing with normal saline. Then the shaped root canals were randomly subdivided into two groups of 4 teeth each according to the carrier-based obturation system use, GuttaCore or experimental HA/PE. Afterwards, the obturated roots stored at 37°C with 100% humidity for 72 hours to allow for complete setting of the sealer. Micro-CT was then scanned to quantify the voids within the root canal space. The data were statistically analyzed by one-way ANOVA and post hoc comparison tests (α=0.05). Results: The root canals obturated with both obturation systems, GuttaCore andexperimental HA/PE showed voids formation, particularly at the apical third of the root canal. GC obturation showed a lower percentage of voids volume (1.54%) than the experimental HA/PE obturation (2.3%). The void volume percentage in the GuttaCore system, however, was non-significantly different (P> 0.05) in comparison with the experimental PE/HA system. Conclusions: GuttaCore and experimental HA/PE obturators exhibited voids formation within the entire root canal space. The experimental HA/PE obturator is comparable to the GuttaCore obturator in terms of voids qualification
Background: Sonographic examination is an important tool in assessment of normal and abnormal cervical lymph nodes. The aim of the study is to assess the distribution and the characteristic features of normal cervical lymph nodes in a sample of Syrian population. Materials and Methods: Fifty healthy Syrian subjects (25 men and 25 women) with an age of 20 -60years old, who had their cervical lymph nodes examined by ultrasound. Three hundred and two lymph nodes were detected. Lymph nodes were evaluated for their number, size, site, echogenic hilus, shape, as well as for the border sharpness. The subjects were categorized by age into four groups, (20 -30, 31 - 40 , 41 - 50 , 51- 60 years ). Statistical analysis of data was done using SP
... Show MoreThe Eurasia Proceedings of Science Technology Engineering and Mathematics | Volume: 6
Background: Dentin removed during root canal system instrumentation for creating adequate geometry for the canal and cleaning the canal. A new instrument had been marketed with the aim of optimum shaping of all parts of the canal system, however, no information present about the amount of dentin removal compared to conventional rotary system. This study investigated the amount of dentin removal when the canal instrumented by SAF compared with ProTaper by using high resolution computed tomography (micro CT). Materials and Methods: Twenty extracted single canalled teeth were utilized for this study; and randomly divided into 2 groups. In the first group, the root canals were prepared by using protaper rotary system till F2 and the root canal
... Show MoreObjective: To evaluate the effect of mouth rinses (Biofresh and ZAK) on the surface micro hardness
of two light cure restorative material (Tetric ceram ivoclar-vivadent) and (3M Z 250) dental
composite.
Methodology: The microhardness values of (sixty) composite specimens were measured at the top
surfaces after 24 hours of immersion in different solutions (Biofresh, Zak mouth wash and distilled
water as control). Comparison done using descriptive statistics (mean, SD, SEM, minimum and
maximum values) and inferential statistics (ANOVA and LSD) test.
Results: The biofresh mouth rinse which has high alcohol containing has less effect on
microhardness of tetric ceram than the zak &distiled water , while the effect
Aim: To evaluate the effect of ultrasonic agitation for retrograde biodceramic root repair, MTA and biodentine filling materials on push-out bond strength to dentine walls. Materials and Methods: Ninety extracted human teeth with single straight roots were selected randomly. After disinfection and cleaning, the coronal portions were sectioned to standardize the root canal length at 15mm. following root canal shaping, obturation and apical roots resection, retrograde cavities were prepared. Teeth were categorized depending on the filling material used into three groups, 30 teeth each. Group A filled with bioceramic root repair material, B with MTA and C with Biodentine material. These groups were divided in to three subgroup (n= 10). Subgrou
... Show MoreThis paper proposes a new method to tune a fractional order PID controller. This method utilizes both the analytic and numeric approach to determine the controller parameters. The control design specifications that must be achieved by the control system are gain crossover frequency, phase margin, and peak magnitude at the resonant frequency, where the latter is a new design specification suggested by this paper. These specifications results in three equations in five unknown variables. Assuming that certain relations exist between two variables and discretizing one of them, a performance index can be evaluated and the optimal controller parameters that minimize this performance index are selected. As a case study, a thir
... Show MoreThis paper proposes a new method to tune a fractional order PID controller. This method utilizes both the analytic and numeric approach to determine the controller parameters. The control design specifications that must be achieved by the control system are gain crossover frequency, phase margin, and peak magnitude at the resonant frequency, where the latter is a new design specification suggested by this paper. These specifications results in three equations in five unknown variables. Assuming that certain relations exist between two variables and discretizing one of them, a performance index can be evaluated and the optimal controller parameters that minimize this performance index are selected. As a case study, a third order linear time
... Show MoreIn this work, mesoporous silica SBA-15 was prepared and functionalized with amine groups (i.e., NH2) to form NH2/SBA-15. The curcumin (CUR) was encapsulated into the surface and pore of NH2/SBA-15 to create CUR@NH2/SBA-15 as an efficient carrier in drug delivery systems (DDSs). The three samples (i.e., SBA-15, NH2/SBA-15, and CUR@NH2/SBA-15) were characterized. The study investigated the effect of the carrier dose, initial CUR concentration, pH, and contact time on the CUR loading efficiency (DLE%) via adsorption. The best DLE% for the SBA-15 and NH2/SBA-15 were found to be 45% and 89.7%, respectively. The Langmuir isotherm had a greater correlation coefficient (R2) of 0.998 for SBA-15. A pseudo-secondorder kinetic model seemed to fit well
... Show More