Background: Green Tea is made from the leaf of the plant “Camellia sinensisâ€. Green tea is reported to contain thousands of bioactive ingredients including catechins which have shown great promise for having antimicrobial effects. Periodontal diseases represent one of the most prevalent diseases around the world and the main etiologic factor behind it, is plaque accumulation, in addition certain kinds of bacteria have been detected frequently in subjects suffering from periodontitis, Several studies suggested that the outcome of periodontal treatment is better if particular pathogens including Aggregatibacteractinomycetemcomitans can no longer be detected after therapy. Materials and Methods: plaque samples were collected from 20 patients suffering from chronic periodontitis with probing pocket depth of at least 6 mm, Aggregatibacteractinomycetemcomitans (A.A) was isolated and diagnosed according to morphological characteristics and biochemical tests. Green tea leaves were extracted by using water and alcohol. The first experiment involved testing the sensitivity of A.A to different concentrations of the extracts using agar well diffusion method,the second experiment involved determination of the minimum inhibitory concentration and then determination of the minimum bactericidal concentration of the extract against the bacteria, laboratory analysis of green tea extracts using high pressure liquid chromatography (HPLC) was performed. Results: Both green tea extracts were effective in inhibition of Aggregatibacteractinomycetemcomitans using agar well diffusion method, 90% and 100% concentrations of alcoholic extract showed larger inhibition zones than chlorhexidinegluconate 0.2% with statistically significant difference, CHX showed higher inhibition zones than all aqueous extract concentrations.The MIC (minimum inhibitory concentration) of alcoholic green tea extract that inhibit Aggregatibacteractinomycetemcomitans growth was 60%, The MIC of aqueous green tea extract that inhibits Aggregatibacteractinomycetemcomitans growth was 70%.The MBC (minimum bactericidal concentration) of alcoholic green tea extract that killsAggregatibacteractinomycetemcomitans was 80%, the MBC of aqueous green tea extract that kills Aggregatibacteractinomycetemcomitans growth was 90%. HPLC analysis of aqueous and alcoholic green tea extracts revealed that alcoholic extract contained higher concentration of EGCG while aqueous extract had higher content of catechin and epicatechin. Conclusion: Green tea extracts were effective against Aggregatibacteractinomycetemcomitans, alcoholic green tea extract showed inhibition ability more than the aqueous green tea extract and more than CHX and it showed bactericidal activity at 80%,90% and 100% concentrations.
The problem of the research is that some companies lack the mechanisms and policies that to enhance the loyalty of these valuable resources, which led to difficulties in generating knowledge, producing, storing, investing and investing information to achieve a sustainable competitive advantage. In addition, companies are still working with the traditional wage system (monthly salaries), which makes people not think about adding value to work. The research aims to determine the level of variables for researchers to clarify the impact of the organizational innovation climate on sustainable competitive advantage. The Qualitative approach is used based on research. The research was applied
... Show MoreThere have been many advances in the solar chimney power plant since 1930 and the first pilot work was built in Spain (Manzanares) that produced 50 KW. The solar chimney power plant is considered of a clean power generation that needs to be investigated to enhance the performance by studying the effect of changing the area of passage of air to enhance the velocity towards the chimney to maximize design velocity. In this experimental and numerical study, the reduction area of solar collector was investigated. The reduction area that mean changing the height of glass cover from the absorbing plate (h1=3.8cm, h2=2.6cm and h3=1.28cm). The numerical study was performed using ANSYS Fluent software package (version 14.0) to solve go
... Show MoreThis contribution investigates structural, electronic, and optical properties of cubic barium titanate (BaTiO3) perovskites using first-principles calculations of density functional theory (DFT). Generalized gradient approximations (GGA) alongside with PW91 functional have been implemented for the exchange–correlation potential. The obtained results display that BaTiO3 exhibits a band gap of 3.21 eV which agrees well with the previously experimental and theoretical literature. Interestingly, our results explore that when replacing Pd atom with Ba and Ti atoms at 0.125 content a clear decrease in the electronic band gap of 1.052 and 1.090 eV located within the visible range of electromagnetic wavelengths (EMW). Optical parameters such as a
... Show MoreReliable estimation of critical parameters such as hydrocarbon pore volume, water saturation, and recovery factor are essential for accurate reserve assessment. The inherent uncertainties associated with these parameters encompass a reasonable range of estimated recoverable volumes for single accumulations or projects. Incorporating this uncertainty range allows for a comprehensive understanding of potential outcomes and associated risks. In this study, we focus on the oil field located in the northern part of Iraq and employ a Monte Carlo based petrophysical uncertainty modeling approach. This method systematically considers various sources of error and utilizes effective interpretation techniques. Leveraging the current state of a
... Show MoreCopper electrodeposition by electrorefining process in acidic sulfate media contains 40 g/l of cupric ions and 160 g/l of sulfuric acid was achieved to study the influence of the operating parameters on cathode purity, surface morphology, deposition rate, current efficiency and power consumption. These operating parameters and there ranges are: current density 200, 300 and 400 A/m2, electrolyte temperature 35, 50 and 65 oC, electrodes spacing 15, 30 and 45 mm and electrolyte residence time 6, 4 and 2 h were utilized. XRF, SEM and EDX analyses were attained to clarify the properties of the produced cathode.
Zinc Oxide thin film of 2 μm thickness has been grown on glass substrate by pulsed laser deposition technique at substrate temperature of 500 oC under the vacuum pressure of 8×10-2 mbar. The optical properties concerning the absorption, and transmission spectra were studied for the prepared thin film. From the transmission spectra, the optical gap and linear refractive index of the ZnO thin film was determined. The structure of the ZnO thin film was tested with X-Ray diffraction and it was formed to be a polycrystalline with many peaks.
Thermal performance of closed wet cooling tower has been investigated experimentally and theoretically
in this work. The theoretical model based on heat and mass transfer equations and heat and mass transfer balance equations which are established for steady state case. A new small indirect cooling tower was used for conducting experiments. The cooling capacity of cooling tower is 1 kW for an inlet water temperature of 38oC, a water mass velocity 2.3 kg/m2.s and an air wet bulb temperature of 26oC. This study investigates the relationship between saturation efficiency, cooling capacity and coefficient of performance of closed wet cooling tower versus different operating parameters such wet-bulb temperature, variable air-spray water fl
This paper details the process of designing, analysing, manufacturing, and testing an integrated solid-state hydrogen storage system. Analysis is performed to optimise flow distribution and pressure drop through the channels, and experimental investigations compare the effects of profile shape on the overall power output from the fuel cell. The storing of hydrogen is given much attention in the selection of a storage medium, and the effect of a cooling system to reduce the recharging time of the hydrogen storage vessel. The PTFE seal performed excellently, holding pressure over 60 bar, despite requiring changing each time the cell is opened. The assembly of the vessel was simple and straightforward, and there was no indication of pressure
... Show More