Background: Coated archwires have been introduced to improve esthetics during orthodontic treatment. Theaim of the present study was to evaluate and compare the load–deflection characteristics and force levels of six brands of coated nickel titanium orthodontic archwires using palatal and gingival deflection. Materials and methods: Ten round wires (0.016 inch) and ten rectangular wires (0.019x0.025 inch) were obtained from each of six brands (G&H, Opal, Ortho Technology, Dany, Hubit and Astar Companies). The load-deflection properties of these archwires were evaluated by the modified bending test usinga readymade dental arch model in both palatal and gingival directions at 37°C temperature using a universal material testing machine. Forces generated at maximum loading of 2mm and at unloading of 1.5mm were measured. Results: All the wires showed hysteresis and significant differences in their load deflection curves, but these differences were more evident in round wires than in rectangular wires where G&H wires showed the widest loading- unloading deflection curves. The maximum loading force of round wires in gingival deflection were higher than by palatal deflection. The force decline during unloading (plateau gap) ranged between 18 to 34% for round wires and 17 to 37% for rectangular wires. Conclusion: Coated epoxy wires (G&H, Opal, Astar and Ortho Technology) produced lower forces compared to polymer (Dany) and Teflon (Hubit) coated round and rectangular archwire.
The potential application of granules of brick waste (GBW) as a low-cost sorbent for removal of Ni+2ions from aqueous solutions has been studied. The properties of GBW were determined through several tests such as X-Ray diffraction (XRD), Energy dispersive X-ray (EDX), Scanning electron microscopy (SEM), and BET surface area. In batch tests, the influence of several operating parameters including contact time, initial concentration, agitation speed, and the dose of GBW was investigated. The best values of these parameters that provided maximum removal efficiency of nickel (39.4%) were 1.5 hr, 50 mg/L, 250 rpm, and 1.8 g/100mL, respectively. The adsorption data obtained by batch experiments subjected to the Three i
... Show MoreThis study presents the debonding propagation in single NiTi wire shape memory alloy into linear low-density polyethylene matrix composite the study of using the pull-out test. The aim of this study is to investigate the pull-out tests to check the interfacial strength of the polymer composite in two cases, with activation NiTinol wire and without activation. In this study, shape memory alloy NiTinol wire 2 mm diameter and linear fully annealed straight shape were used. The study involved experimental and finite element analysis and eventually comparison between them. This pull-out test is considered a substantial test because its results have a relation with behavior of smart composite materials. The pull-out test was carried out by a u
... Show MoreAbstract: The premise of the study is that populism is a process of building political views and critical intellectual orientations among the general public. It is transformed into mass beliefs by mobilizing the society ideologically and continuously in order to reach or control the circle of authority. We distributed the study topics to four sections: In the second, we will discuss the contents of contemporary populism and how other forms of populism evolved historically. The third is to discuss the political discourse of populism among the military regimes and the comparative Islamic parties in the Middle East, especially in terms of the essence and the intellectual foundations. The fourth section seeks to examine the characteristics o
... Show MoreThis paper presents the results of investigating the vibrational characteristics of oblate dish with and without framed structure . A finite element method, was applied to the dynamic analysis of oblate spheroidal shell. Different types of elements were considered in one dimension and two dimensions. It was found that the natural frequencies of oblate shells had two types of behavior against increasing the shell thickness and eccentricity, which are the membrane mode and bending mode –Since – the membrane modes natural frequencies tend to increase with the increasing the eccentricity of oblate, while the bending modes natural frequencies decrease with the increasing the eccentricity till reach the optimum eccentricity.
... Show More
تستهدف هذه الدراسة وبشكل أساس، الكشف عن طبيعة وخصائص البعد السياسي لهندسة/صناعة الخصائص الاجتماعية والسياسية للإنسان والمجتمع، بوصفها العملية المسؤولة عن تصميم هذه الخصائص وصناعتها وتغييرها جزئيا أو كليا، دون أبعادها الأخرى المتعددة والمتنوعة، لا لمجرد الانسياق وراء دوافع الرغبة الذاتية، أو اعتبارات التخصص الدقيق وأحكامه، لأن معهما أيضا، بل وقبلهما أحيانا، دوافع واعتبارات أخرى موضوع
... Show MoreThe evolution of the Internet of things (IoT) led to connect billions of heterogeneous physical devices together to improve the quality of human life by collecting data from their environment. However, there is a need to store huge data in big storage and high computational capabilities. Cloud computing can be used to store big data. The data of IoT devices is transferred using two types of protocols: Message Queuing Telemetry Transport (MQTT) and Hypertext Transfer Protocol (HTTP). This paper aims to make a high performance and more reliable system through efficient use of resources. Thus, load balancing in cloud computing is used to dynamically distribute the workload across nodes to avoid overloading any individual r
... Show MoreObjective(s): The present study aims at studying the relationship between immunoglobulin IgG, IgA,
IgM , as well as to C-3 and C-4 in brain tumours patients immunity (meningioms and gliomas).
Methodology: Forty sera of brain tumour patients were included 20 glioma and 20 meningioma was
tested to determine the levels of IgM, IgG IgA, C-3 and C-4 by using single radial immune-diffusion
technique and compared with 20 apparently healthy blood donors.
Results: The study revealed a significant decreasing in IgG levels in glioma as compare to meningioma
and control. The concentration of two other serum immunoglobulins and complement in both
meningioma and glioma show no significant differences with those in control group.