Background: Biologically active substances, such as Cathepsin B (CAB) which is a lysosomalcystein protease may be involved in periodontal metabolism in the degradation of organic bone matrix containing collagen fibers in response to mechanical stress from orthodontic appliance. The aims of study were to determine and compare salivary levels of CAB, pH as well as clinical periodontal parameters (Plaque index PLI and gingival index GI) with different orthodontic force magnitudes at different time intervals. Materials and methods: A twenty-four patients (both gender) with age range (17-23) years had Angle's Class II division 1 malocclusion with GI >0.5 enrolled in this study. The level of salivary CAB and pH, in addition to the clinical periodontal parameters (PLI and GI) were measured before (baseline), 1 hour (1H), 1 day (1D), 1week (1W), 2 weeks (2W) and 3 weeks (3W) after fixed orthodontic appliance placement with different forces applied to the teeth (F1 (40 gm), F2 (60 gm) and F3 (80 gm)). Results: The highest mean concentration of salivary CAB was (12.057) at F1 in 1D visit with highly significant differences among the visits as well as among the forces (p≤0.05). Weak correlations were revealed between all pairs of forces as well as between each visit with the baseline visit about salivary CAB except the strong negative correlations between F1 with F3 at 3W and baseline with 3W visits at F3. Maintenance of good oral hygiene during the study period demonstrated that the highest mean values of PLI and GI were (0.2) and (0.25) respectively, in addition to the non-significant differences regarding pH among the visits. Conclusion: The concentration of salivary CAB was increased following fixed orthodontic appliance insertion. The very light continuous orthodontic force could produce significant increase of this enzyme activity and give enough effectiveness to produce tooth movement as compared to the higher forces.
Background: Laser is a novel physical therapy technique used to treat various conditions, including wound healing, inhibition of bacterial growth, and postoperative wounds. High-power pulsed alexandrite laser therapy is one of the most prevalent forms of laser therapy, which is a noninvasive method for treating various pathological conditions, thereby enhancing functional capacities and quality of life. It is a modern medical and physiotherapeutic technology. Generally, the Alexandrite laser emits infrared light with a wavelength of 755 nm, allowing it to propagate and penetrate tissues. Objective: This study focused on the application of a high-power pulsed alexandrite laser in vitro to evaluate the effect of a pulsed alexandrite l
... Show MoreThis study present, the density of alum chrom in water and in aqueous solution of poly (ethylene glycol) (1500) at different temperature (288.15, 293.15, 298.15) k. Experimental values of density was used to calculate the apparent molar volume (Vθ), limiting apparent molar volume Vθ˚, experimental slope (Sv) and the partial molar volume at infinite dilution of transfer of solute Δνθ˚. These results have been interpreted the molecular interaction in term of ion- solvent, ion– ion interaction. The structure making /breaking capacities have been inferred from the sign of the second derivative of limiting partial molar volume with respect temperature at constant pressure. Alum has been formed to act as structure breaker in water and aq
... Show MoreBackground: This study was designed to measure the displacement pattern of posterior palatal seal (pps) area in different forms of the palate and with different impression techniques. Materials and method: This study was used to measure the displacement pattern of (pps)in different palatal shapes by using different impression materials Korrecta wax No.4,Green compound and design of House for pps for each palatal forms by using a 3D Scanner of CAD/CAM and measuring the distance between 2 points in pps area by using Caural Threw. Result: The results show highly significant differences between these techniques and the control group (impression with light body) Conclusion: The physiological impression technique of pps with Korecta wax no.4
... Show MoreBackground/purpose: Dental implantology involves different treatments that have been used in conjunction with dental implant surgery to increase implant stability and bone regeneration process. Photobiomodulation( PBM) can be one of these techniques. The objective of this study was to evaluate the bone density around implants. Materials and methods: in this study, 10 individuals had 20 implants inserted in the posterior of their mandibles. each patient received two implants the left side served as the control whereas the right side served as the study group with a diode laser (same patients). measurements were made for each implant. Measurements were obtained using cone-
... Show MoreA total of 400 hard tick specimens (250 ♂♂, 150 ♀♀) were collected from 160 sheep Ovis aries Linnaeus, 1758 out of 200 samples examined in the different localities of Iraq, representing an infestation rate of 80% of the sheep. The results of the current research identified eight species of hard ticks belonging to two genera, Hyalomma C. L. Koch, 1844 and Rhipicephalus Koch,1844 and belonging to the Ixodidae family, as follows: Hyalomma anatolicum Koch, 1844, H. excavatum Koch, 1844, H. impeltatum Schulze & Schlottke, 1930, H. scupense Schulze, 1919, Rhipicephalus bursa Canastrini & Fanzago, 1878, R. camicasi Morel, Mouchet & Rodhain, 1976, R. sanguineus Latreille, 1806, and R. turanicus Pomerantsev, 1936. Molec
... Show MoreBackground: Decalcification of surface enamel adjacent to fixed orthodontic appliances, in the form of white spot lesions, is a wide spread and familiar well-known side effect of orthodontic treatment. The present study was carried out to evaluate the effect of enamel protective agent (Clinpro white varnish) on shear and tensile bond strength of Dentaurum orthodontic stainless steel brackets by using 3M Unitek and Ormco as orthodontic adhesive agents. Materials and methods: Sixty-four extracted human upper first premolar teeth were selected and randomly divided into two groups with 32 teeth each, representing the shear and tensile bond strength testing groups. Then according to the type of bonding adhesive and the addition of Clinpro before
... Show MoreBackground: This study was aimed to investigate the effect of three lingual button (Nickel free / rectangular base, Nickel free / round base and Composite) and bonding environment, wet and dry enamel surface, on: the shear bond strength (SBS) of light and self-cured Resin Modified Glass Ionomer Cements, and the debonding failure sites. Materials and method: One hundred twenty no-carious, free of cracks maxillary first premolar teeth were selected. Three types of orthodontic lingual buttons were used in this study: Nickel free / rectangular base, Nickel free / round base and Composite buttons. The teeth were divided into two groups of sixty teeth each. One group was used for testing the chemically cured GC Fuji Ortho Resin modified Glass Io
... Show MoreObjectives: Dickkopf-1 (DKK-1) is WNT/b-catenin pathway antagonist which plays a detrimental role in the development of diabetic retinopathy (DR). This research aimed to assess serum DKK-1 levels in diabetic patients who have and have not developed DR and, compare them with the control subjects finding out whether we can use it as an indicator for DR early diagnosis and to find out which one of the widely used two groups of antidiabetic treatments had the greater effect on this biomarker and hence on the progression of DR. Methods: The study participants were divided into two subgroups: First, 70 patients (36 male, 34 female) with type 2 diabetes mellitus, among them 35 patients diagnosed with DR and 35 with no evidence of DR, and s
... Show MoreBackground: Limited data are available on the dimensional stability and surface roughness of ThermoSens, which is a material used in denture processing. This study aimed to measure the vertical teeth changes and surface roughness of ThermoSens dentures prepared using three different investment materials. Materials and methods: For the dimensional changes test, 30 complete maxillary dentures were prepared using different investment methods: group I, dental stone; group II, silicone putty; and group III, a mixture of dental stone and plaster (ratio, 1:1; n = 10 for each group). Four screws were attached to the dentures: two were attached to the buccal surface of the canine and first molar, and the other two were attached in the flange areas o
... Show More