Background: Chronic kidney disease is a worldwide health problem, with adverse outcomes of cardiovascular disease and premature death, can be divided into five stages, depending on how severe the damage is to the kidneys, or the level of decrease in kidney function, the final stage of chronic kidney disease is called end-stage renal disease, salivary immunoglobulin A is the main immunoglobulin found in mucous secretions, including tears, saliva, colostrum and secretions from the genitourinary tract gastrointestinal tract, prostate and respiratory epithelium . It is also found in small amounts in blood.This study aimedto measuresalivary flow rate and salivaryimmunoglobulin Alevels in chronic kidney disease patients on hemodialysis treatment in comparison with healthy control subjects. Materials and Methods: Ninety (90) subjects were participated in this study; 45 Patients undergoing hemodialysis with chronic kidney diseases; 45 health control subjects. Saliva collected was measured and levels of salivary immunoglobulin A were measured by Enzyme Link Immunosorbent Assay (Elisa). Results:The present studyrevealed that the mean value of salivary flow rate in chronic kidney disease patients was (0.34 ± 0.19) ml/min, while for healthy control subjects was (1.02 ± 0.39) ml/min, there wasstatisticallysignificantly decrease in salivary flow rate ofchronic kidney disease on hemodialysis patients as compared to control healthy subjects.The present study revealed that the (Mean±SD) of the immunoglobulin A in chronic kidney disease patients on hemodialysis (388.81±227.86) µg./ml, while in control group (273.98±155.89) µg./ml, the result revealed statistically significant increase in chronic kidney disease patients on hemodialysis as compared to control subjects. Conclusions: Salivary immunoglobulin (IgA) reflects the functional capacity of the glands. Increased concentration of this component is usually marker of a poor general condition.
In this work, effects of using different evaporative cooling pads (ECPs) on the energetic and exergetic efficiency of a direct evaporative air cooler (DEAC) have been theoretically and experimentally investigated. Three types of ECPs were used, i.e., honeycomb cellulose cooler pad (HCCP), shading-cloth cooler pad (SCCP), and aspen wood wool cooler pad (AWWCP). For SCCP and AWWCP, a 3-cm pad thickness was used, while for the HCCP, three different values of pad thickness were used, i.e., 3, 5, and 7 cm. Tests were carried out using air velocities of 8, 14, and 19 m/s, measured at the DEAC outlet. Engineering equation solver (EES) used for performing the required calculations of the various parameters affecting the thermal performance of the D
... Show MoreThe pretreatment process can be considered one of the important processes in wastewater treatment, especially coagulation process to decrease the strength of many pollutants. This paper focused on using powdered date seeds as natural coagulant in addition to chemical coagulants (alum and ferric chloride) to find the optimum dosage of each coagulant that makes efficient removal of turbidity and chemical oxygen demand (COD) from domestic wastewater as a pretreatment process, then finding the optimum combined dosages of date seeds with alum, date seeds with ferric chloride that make efficient removal for both pollutants. Concerning turbidity, the optimum dosage for date seeds, alum and ferric chloride were 40 mg/l (79%), 70
... Show MoreAn experimental and theoretical works were carried out to model the wire condenser in the domestic refrigerator by calculating the heat transfer coefficient and pressure drop and finding the optimum performance. The two methods were used for calculation, zone method, and an integral method. The work was conducted by using two wire condensers with equal length but different in tube diameters, two refrigerants, R-134a and R-600a, and two different compressors matching the refrigerant type. In the experimental work, the optimum charge was found for the refrigerator according to ASHRAE recommendation. Then, the tests were done at 32˚C ambient temperature in a closed room with dimension (2m*2m*3m). The results showed that th
... Show MoreThe problem of generated waste as a result of the implementation of construction projects, has been aggravated recently because of construction activity experienced by the world, especially Iraq, which is going through a period of reconstruction, where construction waste represents (20-40%) of the total generated waste and has a negative effect on the environment and economic side of the project. In addition, the rate of consumpted amounts of natural resources are estimated to be about 40% in the construction industry, so it became necessary to reduce waste and to be manage well. This study aims to identify the key factors affecting waste management through the various phases of the project, and this is accom
... Show More