Background: Dimensional changes of acrylic denture bases after polymerization results in need for further adjustments or even ends with technical failure of the finished dentures. The purpose of this study was to estimate the linear dimensional changes for different palatal depths when using multiple investment materials and polymerization techniques. Materials and methods: Ninety upper complete denture bases were constructed for this study. They were divided into two main groups according to the polymerization methods: conventional water bath and experimental autoclave (short and long cycles). Each main group was further subdivided into three subgroups according to the palatal depth (shallow, medium and deep). Furthermore, for each palatal depth; complete denture bases were invested either with dental stone or laboratory silicone. For each upper complete denture, measurements of linear dimensional changes were done by fixation of metallic screws on the tissue surface of the denture base. The distances were measured by using travelling microscope with an accuracy of 0.001 %. The data were statistically analyzed using three way analysis of variance (ANOVA) for three variables, which were (palatal depth, investments and polymerization techniques), LSD test and student T test for comparisons between groups. Results: There were significant improvements in the dimensional accuracy of denture bases cured with autoclave compared with water bath. Also, silicone investments were a successful alternative to stone, study data shows that short autoclave processing with silicone reduces the magnitude of the linear dimensional changes. On the other hand, long autoclave processing and stone investments were better than silicone in reducing dimensional changes. Conclusion: The findings of this study indicates that the use of autoclave processing in acrylic curing is a promising alternative to the conventional water bath and leads to better dimensional stability for the finished dentures in all oral configurations and palatal depths. Also, Silicone is more preferable than stone, although it's not as strong investing materials when compared with stone.
Fifty snails of Paropeas achatinaceum specimens were collected and classified from four areas in Baghdad-Iraq from the period between June and July, 2017. The snails were divided into two groups (each group contain 25 snails). Two environment conditions were used in this study. Natural environment considered as control and experimental environment contains Citrus sinensis (L.) roots as snail’s source food. The comparison result between snail weights in the nature and experimental environment was not significant (0.497, 95% confidence interval [CI] 0.01209–0.02309). Also, the comparison between snail weights in the nature environment and the food mean weight was significant (0.014, 95% confidence interval [CI] 0.00591-0.04109), while the
... Show More: The terrestrial snail Eobania vermiculata (O. F. Müller, 1774) were collected from three station in Baghdad Al- Karkh, Iraq between the period from June 2016 to July 2017. Then we studied the life cycle from the egg to maturity. We studied and photographed the external morphology of it’s shell to identified the species. This species was recorded for the first time in Baghdad.
Despite their long successful use, synthetic dyes have several problems due to their carcinogenic and toxic effects. Besides providing bright colors, some natural pigments have shown notable antimicrobial activity; thus, they could be utilized as functional dyes in many applications such as making colored antimicrobial textiles. In this work, a yellow pigment produced by Streptomyces thinghirensis AF7 and has a notable antimicrobial activity was used to produce a colored antimicrobial textile. The extracted yellow pigment was subjected to a purification step using silica gel column eluted with di ethyl ether solvent. The FTIR, GC-MS and NMR analysis showed that the colorings in this type of product are due to t
... Show MoreThe Jeribe reservoir in the Jambour Oil Field is a complex and heterogeneous carbonate reservoir characterized by a wide range of permeability variations. Due to limited availability of core plugs in most wells, it becomes crucial to establish correlations between cored wells and apply them to uncored wells for predicting permeability. In recent years, the Flow Zone Indicator (FZI) approach has gained significant applicability for predicting hydraulic flow units (HFUs) and identifying rock types within the reservoir units. This paper aims to develop a permeability model based on the principles of the Flow Zone Indicator. Analysis of core permeability versus core porosity plot and Reservoir Quality Index (RQI) - Normalized poros
... Show MoreWith the development of cloud computing during the latest years, data center networks have become a great topic in both industrial and academic societies. Nevertheless, traditional methods based on manual and hardware devices are burdensome, expensive, and cannot completely utilize the ability of physical network infrastructure. Thus, Software-Defined Networking (SDN) has been hyped as one of the best encouraging solutions for future Internet performance. SDN notable by two features; the separation of control plane from the data plane, and providing the network development by programmable capabilities instead of hardware solutions. Current paper introduces an SDN-based optimized Resch
Understanding sedimentation behavior and its transport capacity in the Tigris River is of significant importance owing to the detrimental consequences caused by it. This study investigates the sediment amounts transported along the reach of the Tigris River in Baghdad. The CCHE2D model which is a common tool developed by the National Center for Computational Hydrological Science and Engineering (NCCHE) was applied to investigate the flow pattern and sediment amounts within 7 km reach. The model was initially calibrated and validated under steady-state conditions at the Sarai gauging station (upstream) and its performance was evaluated around the Abu Nawas water treatment plant (downstream). The result shows that the water surfac
... Show MoreBackground:Plant-derived compounds have action alongside Gram-positive and Gram-negative bacteria and numerous compounds, inhibit efflux pumps and hence have become known as efflux pump inhibitors. Clarithromycin is a macrolide antibiotic used to treat pharyngitis, tonsillitis, acute maxillary sinusitis and acute bacterial exacerbation of chronic bronchitis the antibacterial range is the similar as erythromycin but it is active against Mycobacterium avium complex, M.leprae and atypical mycobacteria. The in vitro antibacterial activity results of different boswellic acid compounds discovered alpha keto-boswellic acid (AKBA) to be the preponderance potent antibacterial compound alongside Gram-positive pathogens, but it showed no significant a
... Show More