Preferred Language
Articles
/
jbcd-707
Early and delayed effect of 2% chlorhexidine on the shear bond strength of composite restorative material to dentin using a total etch adhesive
...Show More Authors

Background: Lack of durability of the bond of the dental adhesive systems to tooth structure is one of the most important problems in tooth colored restorative work. This in vitro study was performed to evaluate the effect of 2% chlorhexidine gluconate(CHX) on dentin bond strength by using total etch adhesive system at twenty-four hours and three months of water storage. Material and methods:A flat dentin surface was prepared for forty sound human maxillary premolar teeth which were acid etched with 36% phosphoric acid gel after being divided randomly into four groups of ten teeth each according to storage time and CHX application, theCHX was applied for 60 seconds before adhesive application for groups I and III which were tested after twenty-four hours and three months respectively, while the distal water was applied for 60 seconds before the application of adhesive for group II and IV which were tested after twenty-four hours and three months respectively.The Prime and Bond® NT™ adhesive (Dentsply) was applied and cured, Composite (Ceram X mono, Dentisply) was applied through special mold with 2 mm thickness and light cured, Then all specimens were stored in distilled water 37oC until the time of testing of each group.Shear bond strength test was performed at the end of the storage period (24 hours or 3 months). Results:T-test results showed high statistically significant reduction in shear bond strength (SBS) in non CHX group IV (tested after 3 months) compared to non CHX group II (tested after 24 hours)(P< 0.01). In CHX groups I (tested after 24 hours) and III (tested after 3 months), results showed no statistically significant differences in shear bond strength(p> 0.05).On the other hand result showed statistically no significant differences between groups I and II in 24 hours shear bond strength (P> 0.05). After 3 months water storage, there was statistically high significant differences between the groups III and IV (P< 0.01). Conclusion: the use of 2 % CHX glocounate solution after acid etching and before bonding of dentin have no adverse effect on immediate bond strength (24 hours storage), and was effective in reducing degradation of resin-dentin bond interface after three months of water storage.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Feb 07 2019
Journal Name
Journal Of The College Of Education For Women
Standarized Basics in Depicting Walis in the Early Age of Islam
...Show More Authors

Despite the simplicity that characterized the administration in the era of the Prophet
(peace be upon him), but it put the Muslim community nucleus Administrative Organization
who walked Garret Caliphs (RIP) and came after them, who added to this organization what
they found necessary and dictated by their conditions of life has begun regulation Managing
this appoint leaders and armies of workers on the state and various tribes to spread the Islamic
religion and to teach people the provisions of the Koran and Altfvh in religion and establish
prayer and collect Zakat money so you do not appoint leaders and workers and governors
followed random, but it is in an objective manner takes reasons to meet expectations.

View Publication Preview PDF
Publication Date
Fri Sep 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
FEM: Mono-implant cement retained crown with two different adhesive materials
...Show More Authors

Background: The finite element method (FEM) is expected to be one of the most effective computational tools for measuring the stress on implant-supported restorations. This study was designed using the 3D-FEM to evaluate the effect of two adhesive luting types of cement on the occlusal stress and deformation of a hybrid crown cemented to a mono-implant. Materials and Method: The mono-screw STL file was imported into the CAD/CAM system library from a database supported by De-Tech Implant Technology. This was to assist in the accurate reproduction of details and design of a simulated implant abutment. Virtually, a digital crown was designed to be cemented on an abutment screw. A minimum occlusal thickness of 1mm and marginal fitting of 1.2

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Tue Apr 30 2024
Journal Name
Modern Sport
The effect of Core exercises in improving the strength and flexibility of the spine for injured women with herniated discs in the vertebrae (L4, L5)
...Show More Authors

يعد العلاج الحركي من الوسائل العلاجية التأهيلية من الوسائل المهمة الامنة  لأنها تؤمن على حياة الانسان بكافة شؤونه وتعد التمرينات التأهيلية اسلوبا فعالاً وطبيعياً لا تعرض المريض الى مضاعفات على وظائف الجسم الاخرى لأنها خالية من اي دواء كيمياوي ضار ، كما استخدمت تقنيات حديثة في العلاج الطبيعي بشكل واسع معد حسب اسس علمية منها تمرينات (Core)  التي تساعد في تخفيف الالام بالانزلاق الغضروفي للفقرة الرابعة والخا

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Energy Procedia
Studying the effect of adding buffer gases to CO2 gas on the electron transport parameter
...Show More Authors

View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Fri Jun 01 2012
Journal Name
Journal Of Economics And Administrative Sciences
Analysis of composite variance of experiments carried out according to design Latin box
...Show More Authors

We know that the experiments which conducted by latin square in one location or in one period (season), but there are many cases that need to conduct the same experiments in many locations or in many periods (seasons) to study the interaction  between the treatments and locations or between the treatments and periods (seasons) .In this research we present  an idea for  conduct  the experiment in several locations and in many period (seasons) by using LSD , it represent  acontribution in the area of design and analysis of experiments ,we had written. we had written (theoretically)  the general plans, the mathematical models for these experiments, and finding the derivations of EMS for each component (

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 30 2011
Journal Name
Al-kindy College Medical Journal
Early Outcome of Bifurcational Coronary Artery Stenting
...Show More Authors

BACKGROUND : Bifurcational coronary lesions are
frequent and amounts to almost one fifth of routine
practice concerning up to 15 – 20 % of cases .
Revascularization by percutaneous coronary
intervention ( PCI ), of bifurcational lesion has
become easier by stenting yet it remains a frequent
challenge.
OBJECTIVE : To evaluate the success and hospital
complications of two most frequent technique of stent
deployment in bifurcational PCI.
METHODS : We prospectively analysed the data of
140 consecutive patients with bifurcational PCI at
Ibn_Al-Bitar Hospital for cardiac surgery for the
period from July 2008 to July 2009 .
Depending on whether the side branch was stented or
not, the patient has fa

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 26 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Micro CT analysis of amount of dentin removal created by SAF vs. ProTaper systems
...Show More Authors

Background: Dentin removed during root canal system instrumentation for creating adequate geometry for the canal and cleaning the canal. A new instrument had been marketed with the aim of optimum shaping of all parts of the canal system, however, no information present about the amount of dentin removal compared to conventional rotary system. This study investigated the amount of dentin removal when the canal instrumented by SAF compared with ProTaper by using high resolution computed tomography (micro CT). Materials and Methods: Twenty extracted single canalled teeth were utilized for this study; and randomly divided into 2 groups. In the first group, the root canals were prepared by using protaper rotary system till F2 and the root canal

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 01 2023
Journal Name
Iraqi Journal Of Physics
Studying the Effect of Initial Conditions and System Parameters on the Behavior of a Chaotic Duffing System
...Show More Authors

This work presents a five-period chaotic system called the Duffing system, in which the effect of changing the initial conditions and system parameters d, g and w, on the behavior of the chaotic system, is studied. This work provides a complete analysis of system properties such as time series, attractors, and Fast Fourier Transformation Spectrum (FFT). The system shows periodic behavior when the initial conditions xi and yi equal 0.8 and 0, respectively, then the system becomes quasi-chaotic when the initial conditions xi and yi equal 0 and 0, and when the system parameters d, g and w equal 0.02, 8 and 0.09. Finally, the system exhibits hyperchaotic behavior at the first two conditions, 0 and 0, and the bandwidth of the chaotic

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Residual strength and strengthening capacity of reinforced concrete columns subjected to fire exposure by numerical analysis
...Show More Authors
Abstract<p>This study is a numerical investigation of the performance of reinforced concrete (RC) columns after fire exposure. This study aims to investigate the effect of introducing lateral ties and using the RC jacket on improving post-fire behavior of these columns, the effect of the duration of the fire on ultimate load of columns. The analysis was performed through ABAQUS, a 3D – non-linear finite element program. 4 m tall lengthening square RC column with a cross- section of 0.4 m × 0.4 m was used as a test specimen. The RC column was reinforced by 4Ø28 mm longitudinal bars bonded by steel tie bars of Ø10 mm spaced at 400 mm. The firing temperature was increased to 60</p> ... Show More
Scopus (6)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Fri Feb 01 2019
Journal Name
Construction And Building Materials
Utilization of magnetic water in cementitious adhesive for near-surface mounted CFRP strengthening system
...Show More Authors

Cement-based adhesive (CBA) is used as a bonding agent in Carbon Fibre Reinforced Polymer (CFRP) applications as an alternative to epoxy-based adhesive due to the drawbacks of the epoxy system under severe service conditions which negatively affect the bond between the CFRP and strengthened elements. This paper reports the results of, an investigation carried out to develop two types of CBA using magnetized water (MW) for mixing and curing. Two magnetic devices (MD-I and MD-II), with different magnetic field strengths (9000 and 6000 Gauss) respectively, were employed for water magnetization. Different water flows with different water circulation times in the magnetizer were used for each device. Compressive and splitting tensile strength te

... Show More
Scopus (12)
Crossref (11)
Scopus Clarivate Crossref