Preferred Language
Articles
/
jbcd-707
Early and delayed effect of 2% chlorhexidine on the shear bond strength of composite restorative material to dentin using a total etch adhesive
...Show More Authors

Background: Lack of durability of the bond of the dental adhesive systems to tooth structure is one of the most important problems in tooth colored restorative work. This in vitro study was performed to evaluate the effect of 2% chlorhexidine gluconate(CHX) on dentin bond strength by using total etch adhesive system at twenty-four hours and three months of water storage. Material and methods:A flat dentin surface was prepared for forty sound human maxillary premolar teeth which were acid etched with 36% phosphoric acid gel after being divided randomly into four groups of ten teeth each according to storage time and CHX application, theCHX was applied for 60 seconds before adhesive application for groups I and III which were tested after twenty-four hours and three months respectively, while the distal water was applied for 60 seconds before the application of adhesive for group II and IV which were tested after twenty-four hours and three months respectively.The Prime and Bond® NT™ adhesive (Dentsply) was applied and cured, Composite (Ceram X mono, Dentisply) was applied through special mold with 2 mm thickness and light cured, Then all specimens were stored in distilled water 37oC until the time of testing of each group.Shear bond strength test was performed at the end of the storage period (24 hours or 3 months). Results:T-test results showed high statistically significant reduction in shear bond strength (SBS) in non CHX group IV (tested after 3 months) compared to non CHX group II (tested after 24 hours)(P< 0.01). In CHX groups I (tested after 24 hours) and III (tested after 3 months), results showed no statistically significant differences in shear bond strength(p> 0.05).On the other hand result showed statistically no significant differences between groups I and II in 24 hours shear bond strength (P> 0.05). After 3 months water storage, there was statistically high significant differences between the groups III and IV (P< 0.01). Conclusion: the use of 2 % CHX glocounate solution after acid etching and before bonding of dentin have no adverse effect on immediate bond strength (24 hours storage), and was effective in reducing degradation of resin-dentin bond interface after three months of water storage.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Oct 01 2023
Journal Name
Journal Of Education And Health Promotion
The net atrioventricular compliance in mild to moderate hypertensive patients during the early left ventricle filling: A case series
...Show More Authors
BACKGROUND:

The compliance is considered one of the most important parameters which is defined as the change in volume with given change in pressure (dv/dp). It is varying inversely with both diastolic filling and modulus of chamber stiffness.

AIMS:

This study aimed to deduce the net atrioventricular compliance which is affected the trans mitral blood flow.

MATERIALS AND METHODS:

This study focuses on study group of 25 patients (15 males

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Jul 01 2021
Journal Name
University Of Northampton Pue
Validating a Proposed Data Mining Approach (SLDM) for Motion Wearable Sensors to Detect the Early Signs of Lameness in Sheep
...Show More Authors

View Publication
Publication Date
Fri Dec 31 2021
Journal Name
Dental And Medical Problems
Effect of the local application of bupivacaine in early pain control following impacted mandibular third molar surgery: A randomized controlled study
...Show More Authors

Background: Postoperative pain is one of the main complications following impacted mandibular third molar (IMTM) surgery. Objectives: The aim of this study was to assess the effect of the local application of bupivacaine on reducing early postoperative pain following IMTM surgery. Material and methods: A prospective, single-blinded, randomized controlled study was conducted on 40 patients who had undergone the surgical removal of an IMTM under local anesthesia. In the study group (n = 20), absorbable gelatin sponge (AGS) soaked in 3 mL of 0.5% plain bupivacaine hydrochloride was locally applied in the post-extraction socket. In the control group (n = 20), AGS soaked in 3 mL of normal saline was used. Pain intensity was assessed using a pa

... Show More
View Publication
Scopus (11)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Sun Oct 01 2023
Journal Name
Nanomedicine Research Journal
The effect of ZrO2 NPs addition on denture adaptation and diametral compressive strength of 3D printed denture base resin
...Show More Authors

Objective(s): The world of dentistry is constantly evolving, and with the advent of 3D printing technology, the possibilities are endless. However, little is known about the effects of adding ZrO2 NPs to the denture base resin of 3D additive manufacturing technique.Aim of this study is to evaluate the behavior of resin which is used to 3D printing of denture base with the addition of ZrO2 NPs on denture adaptation property and diametral compression strength.Methods: 60 samples were printed, 30 disks for diametral compressive test and 30 denture base for denture adaptation test. Three groups per test (n=10). The control group for each test included unreinforced 3Dprinted denture base resin, and the other groups were  reinforced with (2&

... Show More
View Publication
Publication Date
Sun Mar 04 2018
Journal Name
Baghdad Science Journal
Synthesis and Characterization of a Molecularly Imprinted Polymer for Diclofenac Sodium Using (2-vinylpyridine and 2-hydroxyethyl metha acrylate) as the Complexing Monomer
...Show More Authors

Four electrodes were synthesized based on molecularly imprinted polymers (MIPs). Two MIPs were prepared by using the diclofenac sodium (DFS) as the template, 2-hydroxy ethyl metha acrylate(2-HEMA) and 2-vinyl pyridine(2-VP) as monomers as well as divinyl benzene and benzoyl peroxide as cross linker and initiator respectively. The same composition used for prepared non-imprinted polymers (NIPs) but without the template (diclofenac sodium). To prepared the membranes electrodes used different plasticizers in PVC matrix such as: tris(2-ethyl hexyl) phosphate (TEHP), tri butyl phosphate (TBP), bis(2-ethyl hexyl) adipate (BEHA) and tritolyl phosphate (TTP). The characteristics studied the slop, detection limit, life time and linearity range of DF

... Show More
View Publication Preview PDF
Scopus (12)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Fri Jun 11 2021
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of composite bonding spot size and location on the performance of poly-ether-ether-ketone (PEEK) retainer wires
...Show More Authors

Background: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center of t

... Show More
View Publication Preview PDF
Scopus (14)
Crossref (13)
Scopus Crossref
Publication Date
Fri Jun 11 2021
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of composite bonding spot size and location on the performance of poly-ether-ether-ketone (PEEK) retainer wires
...Show More Authors

Background: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center

... Show More
Scopus (14)
Crossref (13)
Scopus Crossref
Publication Date
Fri Feb 13 2026
Journal Name
Journal Of Physical Education
The impact of a training field in Lake Al-Razzaza to develop the strength of the legs and arms for young boxers
...Show More Authors

View Publication
Publication Date
Fri Nov 30 2018
Journal Name
Civil Engineering Journal
Determining the Causes of Punching Shear in Reinforced Slabs Using Fishbone Diagram
...Show More Authors

Risk identification and assessment can be analysed using many risk management tools. Fishbone diagram is one of these techniques which can be employed, for the identification of the causes behind the construction failure, which   has become a phenomenon that often gets repeated in several projects. If these failures are not understood and handled scientifically, it may lead to disputes between the project parties. Additionally, the construction failure also leads to an increase in the project budget, which in turn causes a delay in the completion of the projects. Punching shear in reinforcement slab may be one of the reasons for construction failures. However, there are many doubts about other causes that lead to this failure as w

... Show More
Crossref (3)
Clarivate Crossref
Publication Date
Fri Apr 01 2022
Journal Name
World Congress On Civil, Structural, And Environmental Engineering
Improving the Behavior of Steel Plate Shear Wall Using Double Infill Plates
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Crossref