Background: Irrigation of the canal system permits removal of residual tissue in the canal anatomy that cannot be reached by instrumentation of the main canals so the aim of this study was to compare and evaluate the efficiency of conventional irrigation system, endoactivator sonic irrigation system,P5 Newtron Satelec passive ultrasonic irrigation and Endovac irrigation system in removing of dentin debris at three levels of root canals and to compare the percentage of dentin debris among the three levels for each irrigation system. Materials and methods: Forty extracted premolars with approximately straight single root canals were randomly distributed into 4 tested groups of 10 teeth each. All canals were prepared with Protaper Universal hand files to size #F4, and irrigated with 2.5% NaOCI 1 ml between files and 5ml for 60 seconds as a final irrigant by different irrigation devices; group one, by using conventional system; group two, by using Endoactivator sonic irrigation system, group three, by using Satelec Passive Ultrasonic irrigation and group four by using the Endovac system. After the final irrigation, the roots were split longitudinally and photographed with a digital microscope. The roots were magnified to 100X; a percentage of debris was calculated for the apical 0-3, middle 3-6 and coronal 6-9 mm. The debris score was calculated as a percentage of the total area of the canal that contained debris as determined by pixels in Adobe PhotoshopCS5. Data were analyzed statistically by ANOVA and LSD at 5% significant level. Results: when comparing the debris remaining, the Endovac, Endoactivator and Satelec groups showed significantly less debris than the conventional group at all three levels (p < 0.01). The Endovac group showed significantly less debris than the Endoactivator group at middle and coronal levels while no significant difference found between the Endovac system and Endoactivator system at apical level. The apical 0-3 mm showed significantly more debris than both the middle and coronal level for all groups. Conclusion: The EndoVac system showed a higher cleaning capacity of the canal at all levels, followed by the protocols that used Endoactivator sonic irrigation system. The conventional irrigation system with maxi-i-probe needles showed inferior results. The apical three millimeters showed a greater amount of debris than the 3-9 millimetres from the working length, regardless of the irrigation device used.
There are significant differences between the pre and post-tests in favor of the post-test in the tests) stroke volume (S.V), cardiac thrust (C.O.P), left ventricular volume, maximum oxygen consumption Vo2max), which indicates the effect of the proposed training approach.There are significant differences between the pre and post-tests in favor of the post-test in the achievement level test with air rifle shooting for young female shooters, which indicates the effect of the proposed training curriculum.There are no significant differences between the pre and post-tests in the tests (heart rate (HR) before exercise, heart rate (HR) after exercise, systolic blood pressure rate before exercise, systolic blood pressure rate after exercis
... Show MoreIn this paper, split-plate airlift electrochemical reactor as an apparatus with new configuration for wastewater treatment was provided. Two aluminum plates were fixed inside the reactor and present two functions; first it works as split plates for internal loop generation of the airlift system (the zone between the two plates acts as riser while the other two zones act as downcomer) and second it works as two electrodes for electrocoagulation process. Simulated wastewater contaminated with zinc ions was used to test the performance of this apparatus for zinc removal by studying the effect of different experimental variables such as initial concentration of zinc (50-800 ppm), electrical current density (2.67-21.4 mA/cm2), init
... Show MoreCold atmospheric plasma (CAP) is used widely in medical and biological fields because of non-thermal effected. Direct application of plasma is preferred in medical functions, so, direct application of cold plasma has obtained by the floating electrode dielectric barrier discharge (FE-DBD) system. The purpose of this paper to review the effect of (CAP) on the reproductive hormones (testosterone, LH, E2, progesterone, for male rats. The study appeared that no significant effect on E2 and progesterone hormone for all time of exposure, besides this significant difference in LH hormone (P<0.05) at 15 sec, (P<0.0001) at 30, 90 sec and (P<0.001) at 60 sec of exposure to plasma. Added to that significant difference (P<0.01) at 15, 30, 60 sec and no
... Show MoreThe aim of this work is to study the effect of diesel fuel percentage on the combustion processes in compression ignition engine using dual – fuel (diesel and LPG).
The brake thermal efficiency increased with the increase of diesel fuel rate at low loads, and decreased when load increased. To get sufficient operation in engine fueled with dual fuel, it required sufficient flow rate of diesel fuel, if the engine fueled with insufficient diesel fuel erratic operation with miss fire cycles presented.
Dual-fuel operation at part load showed higher specific fuel consumption than straight diesl operation. At full loads, brake specific fuel consumption of duel fuel engine approaches that for diesel fuel values.