Preferred Language
Articles
/
jbcd-705
A study to compare the cleaning efficiency of different irrigation systems for macro debris removal in instrumented canals (An in vitro study)
...Show More Authors

Background: Irrigation of the canal system permits removal of residual tissue in the canal anatomy that cannot be reached by instrumentation of the main canals so the aim of this study was to compare and evaluate the efficiency of conventional irrigation system, endoactivator sonic irrigation system,P5 Newtron Satelec passive ultrasonic irrigation and Endovac irrigation system in removing of dentin debris at three levels of root canals and to compare the percentage of dentin debris among the three levels for each irrigation system. Materials and methods: Forty extracted premolars with approximately straight single root canals were randomly distributed into 4 tested groups of 10 teeth each. All canals were prepared with Protaper Universal hand files to size #F4, and irrigated with 2.5% NaOCI 1 ml between files and 5ml for 60 seconds as a final irrigant by different irrigation devices; group one, by using conventional system; group two, by using Endoactivator sonic irrigation system, group three, by using Satelec Passive Ultrasonic irrigation and group four by using the Endovac system. After the final irrigation, the roots were split longitudinally and photographed with a digital microscope. The roots were magnified to 100X; a percentage of debris was calculated for the apical 0-3, middle 3-6 and coronal 6-9 mm. The debris score was calculated as a percentage of the total area of the canal that contained debris as determined by pixels in Adobe PhotoshopCS5. Data were analyzed statistically by ANOVA and LSD at 5% significant level. Results: when comparing the debris remaining, the Endovac, Endoactivator and Satelec groups showed significantly less debris than the conventional group at all three levels (p < 0.01). The Endovac group showed significantly less debris than the Endoactivator group at middle and coronal levels while no significant difference found between the Endovac system and Endoactivator system at apical level. The apical 0-3 mm showed significantly more debris than both the middle and coronal level for all groups. Conclusion: The EndoVac system showed a higher cleaning capacity of the canal at all levels, followed by the protocols that used Endoactivator sonic irrigation system. The conventional irrigation system with maxi-i-probe needles showed inferior results. The apical three millimeters showed a greater amount of debris than the 3-9 millimetres from the working length, regardless of the irrigation device used.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 01 2012
Journal Name
Annals Of Agricultural Sciences
Water use efficiency of potato (Solanum tuberosum L.) under different irrigation methods and potassium fertilizer rates
...Show More Authors

View Publication
Scopus (56)
Crossref (50)
Scopus Crossref
Publication Date
Tue Apr 11 2023
Journal Name
Periodicals Of Engineering And Natural Sciences (pen)
The role of digital content systems used in managing Arab academic scientific journals: An analytical study
...Show More Authors

View Publication Preview PDF
Crossref
Publication Date
Thu Mar 01 2012
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The Capability to a chive An Effective Marketing Performance In Banks: applied Study in a sample of Iraqi Banks
...Show More Authors

The marketing of banking service is considered to be one of the impotent fields which showed a universal inebriates . He research showed the comparison between the application of marketing in ideas and application for loot government and private Iraqi bank. The research comets of four parts; Mythology / the concept and the importance of Banking Marketing / Research applichlion/ Conelnion and  recommendation.

View Publication Preview PDF
Publication Date
Mon May 05 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The influence of cavity design for cusp coverage on fracture strength of weakened maxillary first premolars using two esthetic restorative systems (CAD/CAM hybrid ceramic and nanohybrid composite) (An in vitro study)
...Show More Authors

Background: Maxillary first premolar with wide MOD cavity more susceptible to fracture. The aim of this study was to assess the influence of cavity design for cusp coverage on the fracture resistance of weakened maxillary first premolar restored with CAD/CAM hybrid ceramic versus nanohybide composite. Materials and Methods: Fifty six intact maxillary first premolars of approximately comparable sizes were divided into seven groups eight for each: Group A: Intact teeth (control group); Group B: teeth prepared for MOD inlay; Group C: teeth prepared for MOD onlay covering the lingual cusp; Group D: teeth prepared for MOD covering buccal and lingual cusps ,the previous three groups indirectly restored with nanohybrid composite (3M ESPE Z 250 X

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2011
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of the accuracy of a fifth generation apex locator (in vitro study)
...Show More Authors

Background: The use of electronic apex locators for working length determination eliminates many of the problems associated with the radiographic measurements (interference of anatomical structures, errors in projection such as elongation or shortening, and lack of three-dimensional representation). Its most important advantage over radiography is that it measures the length of the root canal to the apical constriction, not to the radiographic apex. The aim of this study was to assess the accuracy of a new fifth generation apex locator (Joypex 5) in recording the apical constriction and comparing it with a third generation apex locator (Root ZX) in vitro. Materials and method: Twenty four single-rooted sound human premolars, extracted for t

... Show More
Preview PDF
Publication Date
Mon May 05 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An Evaluation of the Efficacy of Different Gingival Retraction Materials on the Gingival Tissue Displacement (A Comparative In Vivo Study)
...Show More Authors

Background: An accurate adaptation of the crown to the finish line is essential to minimize cement dissolution and to preserve periodontium in fixed partial denture cases. An accurate adaptation of crown is possible only when preparation details are captured adequately in the impression and transferred to cast. For these reasons, gingival displacement is necessary to capture subgingival preparation details.The aim of the present study is to measure in vivo the horizontal displacement of the gingival sulcus obtained by using three new cordless retraction materials (Magic Foam Cord®, Racegel and Astringent Retraction Paste) in comparison to medicated retraction cord. Materials and method: Thirty-two patients requiring porcelain fused to me

... Show More
View Publication Preview PDF
Publication Date
Mon May 05 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Tensile force measurement by using different lingual retainer wires, bonding materials types and thickness (A comparative in vitro study)
...Show More Authors

Background: The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate the tensile forces of selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. Materials and Methods: The study sample includes 120 wires with three types of retainer wires (3 braided strands\ Orthotechnology, 8 braided strands\ G&H Orthodontics, 6 coaxial strands\ Orthoclassic wires), two types of adhesive (flowable\ Orthotechnology, non flowable\ G&H O

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Under Different Priors &Two Loss Functions To Compare Bayes Estimators With Some of Classical Estimators For the Parameter of Exponential Distribution
...Show More Authors

المستخلص:

          في هذا البحث , استعملنا طرائق مختلفة لتقدير معلمة القياس للتوزيع الاسي كمقدر الإمكان الأعظم ومقدر العزوم ومقدر بيز في ستة أنواع مختلفة عندما يكون التوزيع الأولي لمعلمة القياس : توزيع لافي  (Levy) وتوزيع كامبل من النوع الثاني وتوزيع معكوس مربع كاي وتوزيع معكوس كاما وتوزيع غير الملائم (Improper) وتوزيع

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 02 2012
Journal Name
Journal Of Planner And Development
the population in Iraq up to 2035 an analytical study
...Show More Authors

The population studies are one of the difficult tasks facing the world in all periods. most of the researchers and who have relationship to population policies and development plans, may have succumbed to the idea that the population problem is based and confined mainly in the rate of increase in population, or the so – called population explosion, and not the content because of its pressure on resources and there is no problem of population if the resources are available and therefore no need for the development and implementation of population policies in any way . While the population policies here should take a range of general and comprehensive in every respect to population and demographic phenomena distribution, not only

... Show More
View Publication
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Human Skin WoundWelding Using 980 nm Diode Laser: an in Vitro Experimental Study
...Show More Authors

Laser assisted skin wound closure offers many distinct advantages over conventional closure
techniques. The objective of this in vitro experimental study, carried out at the Institute of Laser for
Postgraduate Studies/Baghdad University, was to determine the effectiveness of 980 nm diode laser in
welding of human skin wounds. Multiple 3-4 cm long full thickness incisions in a specimen of human
skin obtained from the discarded panniculus of an Abdominoplasty operation were tried to be laser
welded using a 4 mm spot diameter laser beam from a 980 nm diode laser at different laser parameters
and modes of action. The tensile strength at the weld site was analyzed experimentally. Although laser
assisted wound welding did

... Show More
View Publication Preview PDF