Background: One common undesirable side effect of orthodontic treatment with fixed appliances is the development of incipient caries lesions around brackets, particularly in patients with poor oral hygiene. Different methods have been used to prevent demineralization; the recent effort to improve the resistance against the demineralization is by the application of lasers. Materials and method: Thirty human premolars extracted for orthodontic purposes were used to test the effect of two energy level of ER-YAG laser on enamel resistance to demineralization. The brackets were bonded on the teeth and all the labial surface excluding 2 mm area gingival to the brackets were painted with acid resistance varnish. Three groups were generated. The first group was the control group (A), with no treatment was performed. In group II (B)and groups III (C); teeth were irradiated by ER-YAG laser of 200, 60 mj energy respectively. All the teeth were individually subjected to acid challenge cycle for 30 days. After debonding longitudinal sections were taken and examined under stereomicroscope. The enamel demineralization evaluation was done by taking the average of three depths at the centre of the artificial lesion. Also the enamel surface was classified by an experienced investigator according to acid etch pattern. Comparisons of the average depth values of the groups were performed with ANOVA and LSD tests. The statistical significance level was set at p ≤ 0.05. Results: The results revealed that average lesion depth was significantly deeper at the control group than the laser groups, and its significantly deeper in group (B) 200 mj than in group (C) 60 mj, enamel surfaces showed deeper pits and craters than in control group. Conclusions: the decrease in artificial caries lesion depth associated with use of the two laser energy level support the ER-YAG laser as a tool to increase enamel resistance to demineralization and white spot lesion prevention. Key words: Demineralization, ER-YAG, laser.
Abstract: The increased interest in developing new photonic devices that can support high data rates, high sensitivity and fast processing capabilities for all optical communications, motivates a pre stage pulse compressor research. The pre-stage research was based on cascading single mode fiber and polarization maintaining fiber to get pulse compression with compression factor of 1.105. The demand for obtaining more précised photonic devices; this work experimentally studied the behavior of Polarization maintaining fiber PMF that is sandwiched between two cascaded singe mode fiber SMF and fiber Bragg gratings FBG. Therefore; the introduced interferometer performed hybrid interference of both Mach-Zehnder
... Show MoreThe search is an application for one of the problems of mathematics in the computer; as providing construction and design of a major program to calculate the inverse permutations of the symmetric group Sn , where 1 ≤ n ≤ 13; using some of the methods used in the Number Theory by computer . Also the research includes design flow chart for the main program and design flow chart for the program inverse permutations and we give some illustrative examples for different symmetric groups and their inverse permutations.
In this paper , the CO2 laser receiver system is designed and studied, with wavelength laser 10.6 ?m in room temperature , and to evaluate the performance and discussion it via the package of optical design (ZEMAX), from its output the Spot Diagram is measured through RMS ,and from the Ray fan plot , the aberrations is found which is the normal error for the best focus named (under corrected ) , the other output was the Geometric Encircled Energy in the spot diagram . and found that the radius of spot diagram at 80% (R80%) from the total energy ,and focal shift .The designed system have high efficiency and low cost .
Stick- slip is the continuous stopping& release of the Bit/BHA due to the irregular down-hole rotation prompted by the existing relationship between the friction torque and the torque applied from the surface to free the bit.
Friction coefficient between BHA and wellbore is the main player of stick slip amount, which can be mitigated by support a good lubricators as additives in drilling mud.
Mathematical (or empirical) solves should be done through adjusting all parameters which supposed to reduce stick- slip as low as possible using different models, one of the main parameters is drilling mud. As per Nanoparticles drilling fluid is a new technology that offers high performance
... Show MoreThis article discusses the function of semiotics in political discourse after the socio-political processes taking place in Iraq since 2003 and its role in the development of textual criticisms of some Iraqi politicians, analyzes the reasons for its functioning in the speech of politicians. The research is mainly focused on finding out to what extent political text studies draw on sign systems that can store and transmit information, the nature of its purpose and the use of available fields for the purpose to be achieved. The chief purpose of the study is to investigate and also clarify the symbols and signs appear within the framework of discursive Iraqi politicians, the nature of the symbols used, and the meanings that are include
... Show MoreJoining tissue is a growing problem in surgery with the advancement of the technology and more precise and difficult surgeries are done. Tissue welding using laser is a promising technique that might help in more advancement of the surgical practice. Objectives: To study the ability of laser in joining tissues and the optimum parameters for yielding good welding of tissues. Methods: An in-vitro study, done at the Institute of Laser, Baghdad University during the period from October 2008 to February 2009. Diode and Nd-YAG lasers were applied, using different sessions, on sheep small intestine with or without solder to obtain welding of a 2-mm length full thickness incision. Different powers and energies were used to get maximum effect. Re
... Show MoreABSTRACT: BACKGROUND: Arthroscopic knee surgeries are performed in very large numbers worldwide, and in spite of relatively low complication rate, but the total number is significant. Some of these complications are due to tourniquet use and can be serious. OBJECTIVE: Is to asses if automated pump (with or without) dilute epinephrine saline irrigation can replace the tourniquet use in soft tissue arthroscopic knee surgeries. PATIENTS AND METHODS: 36 patients (9 females 25 % and 27 males 75 %) were included in this prospective experimental nonrandomized study, and were necessitated soft tissue arthroscopic knee surgeries. Patients were divided into two groups, in group A (patients) tourniquet and automated pump were used. In group B (18 pati
... Show MoreThe work reported in this study focusing on the abrasive wear behavior for three types of pipes used in oil industries (Carbone steel, Alloy steel and Stainless steel) using a wear apparatus for dry and wet tests, manufactured according to ASTM G65. Silica sand with
hardness (1000-1100) HV was used as abrasive material. The abrasive wear of these pipes has been measured experimentally by measuring the wear rate for each case under different sliding speeds, applied loads, and sand conditions (dry or wet). All tests have been conducted using sand of particle size (200-425) µm, ambient temperature of 34.5 °C and humidity 22% (Lab conditions).
The results show that the material loss due to abrasive wear increased monotonically with