Background: The purpose of the current study was to evaluate the efficacy of a new orthodontic bonding system (Beauty Ortho Bond) involving the shear bond strength in dry and wet environments, and adhesion remnant index (ARI) scores evaluation in regard to other bonding systems (Heliosit and Resilience Orthodontic Adhesives). Materials and methods: Sixty defect free extracted premolars were randomly divided into six groups of 10 teeth each, mounted in acrylic resin, three groups for a dry environment and three for a wet one. Shear bond strength test was performed with a cross head speed of 0.5 mm/min, while surfaces of enamel and bracket-adhesive-enamel surfaces were examined with stereomicroscope For ARI scores evaluation. Data were analyzed by one way analysis of variance, least significant difference, student's t-test, and Fisher exact test. Results: The mean shear bond strength showed highest values for Resilience adhesive followed by Beauty Ortho Bond and Heliosit adhesives respectively both in dry and wet environments. Interestingly, there was a non-significant difference (P<0.05) between Resilience and Beauty Ortho Bond adhesives using least significant difference at dry environment. In wet environment the Beauty Ortho Bond showed an acceptable mean shear bond strength value (6.39 Mpa) which is considered as a clinically acceptable value. Adhesive remnant index scores demonstrated a tendency towards score 1 in dry environment, and towards score 3 in wet environment, the scores also showed a non-significant difference (P<0.05) between Resilience and Beauty Ortho Bond adhesives using Fischer exact test. Conclusion: Beauty Ortho Bond is less sensitive to wet environment than Resilience and Heliosit adhesives, therefore it has an advantage during clean up, as it reduces the risk of enamel damage during debonding procedure. Keywords: Beauty Ortho Bond, Shear bond strength, light cured composite.
The present study investigates the effect of the de-sanding (recycling system) on the bearing capacity of the bored piles. Full-scale models were conducted on two groups of piles, the first group was implemented without using this system, and the second group was implemented using the recycling system. All piles were tested by static load test, considering the time factor for which the piles were implemented. The test results indicated a significant and clear difference in the bearing capacity of the piles when using this system. The use of the recycling system led to a significant increase in the bearing capacity of the piles by 50% or more. Thus it was possible to reduce the pile length by (15 % or more) thus, and implementation c
... Show MoreThe present study investigates the effect of the de-sanding (recycling system) on the bearing capacity of the bored piles. Full-scale models were conducted on two groups of piles, the first group was implemented without using this system, and the second group was implemented using the recycling system. All piles were tested by static load test, considering the time factor for which the piles were implemented. The test results indicated a significant and clear difference in the bearing capacity of the piles when using this system. The use of the recycling system led to a significant increase in the bearing capacity of the piles by 50% or more. Thus it was possible to reduce the pile length by (15 % or more) thus, and implementation costs
... Show MoreThe goal of the research is to develop a sustainable rating system for roadway projects in Iraq for all of the life cycle stages of the projects which are (planning, design, construction and operation and maintenance). This paper investigates the criteria and its weightings of the suggested roadway rating system depending on sustainable planning activities. The methodology started in suggesting a group of sustainable criteria for planning stage and then suggesting weights from (1-5) points for each one of it. After that data were collected by using a closed questionnaire directed to the roadway experts group in order to verify the criteria weightings based on the relative importance of the roadway related impacts
... Show MoreBackground: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center
... Show MoreBackground: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center of t
... Show MoreBackground: This in vitro study was carried out to investigate the effect of post space regions (coronal, middle and apical), the effect of post types ( Manually Milled Zirconia post, Prefabricated Fiber post, prefabricated Zirconia post) and the type of cement used (GIC, self-adhesive resin cement) on the bond strength between the posts and root dentin by using push-out test. Material and methods: Forty eight mandibular premolars extracted for orthodontic reasons (single rooted) were instrumented with ProTaper system (hand use) and obturated with gutta percha for ProTaper using AH26® root canal sealer following the manufacturer instructions. After 24 hours, post space was prepared using Zirix and Glassix drills no.3 creating 8 mm dept
... Show MoreIn this work, the possibility to use new suggested carriers (D= Aspirin, Ibuprofen, Paracetamol, Tramal) is discussed for diclofenac drug (voltarine) by using quantum mechanics calculations. The calculation methods (PM3) and (DFT) have been used for determination the reaction path of (O-D) bond rupture energies. Different groups of drugs as a carrier for diclofenac prodrugs (in a vacuum) have been used; at their optimized geometries. The calculations included the geometrical structure and some of the physical properties, in addition to the toxicity, biological activity, and NLO properties of the prodrugs, investigated using HF method. The calculations were done by Gaussian 09 program. The comparison was made for total energies of reactan
... Show MoreBackground: fixed orthodontic appliances deleterious influence on gingival health is well documented. Association between weight status and gingival health is presented in many studies. This study aimed to evaluate how early the impact of fixed orthodontic therapy on patients` gingival health, and if there are differences of that impact among different weight status groups. Materials and Methods: Sample consisted of 54 patients (25 males, 29 females; age limits are 16 -18 years) going under the course of treatment with fixed orthodontic appliance. Patients were categorized according to their Body Mass Index (BMI) into 3 weight status groups considering WHO charts in 2007 (underweight, normal weight, overweight and obese), then determinat
... Show MoreBackground: The development of orthodontic biomaterials that attract less biofilm has been a goal for decades. Adhesion and colonization of cariogenic streptococci are considered to play key roles in the development of enamel demineralization related to orthodontic materials. The aim of this study was to quantitatively evaluate the Mutans streptococci adhesion to coated orthodontic archwires (Epoxy and Teflon) and uncoated archwires (stainless steel and nickel-titanium) with respect to incubation time in the presence and absence of saliva. Material and Method: Six types of archwires stainless steel and nickel titanium with two type of coating (Epoxy, Teflon) were used in this study. Twelve specimens of each archwire were incubated in steri
... Show MoreBackground: The prevention of the enamel demineralization at the periphery of the brackets is a significant challenge to orthodontic professionals. The aim of this clinical study was to compare the Streptococcus mutants count in the plaque surrounding two orthodontic adhesive types, Fuji Ortho LC and Enlight (Ormco). Materials and methods: A total of 13 patients (7 male and 6 female) needing fixed orthodontic appliance therapy were participated. A split mouth technique was followed with appliances bonded by two orthodontic adhesive types, Fuji Ortho LC and Enlight (Ormco). Saliva was collected before placement of appliances (T0) and again at three weeks (T1) and six weeks (T2) after placement of appliances. Plaque was collected from areas a
... Show More