Background: Simultaneous and staged guided bone regeneration (GBR) is one of the several surgical techniques that have been developed in the past two decades to regenerate bone and thus to allow implant placement in compromised sites (fenestration and dehiscence). It is a surgical procedure that consists of the placement of a cell-occlusive physical barrier between the connective tissue and the alveolar bone defect. The treatment concept advocates that regeneration of osseous defects is predictably attainable via the application of occlusive membranes, which mechanically exclude non-osteogenic cell populations from the surrounding soft tissues, thereby allowing osteogenic cell populations originating from the parent bone to inhabit the osseous wound. Augmentation utilizing guided bone regeneration (GBR) has become a major treatment option to provide optimal bone to support Osseointegrated dental implants. One of the objectives of GBR is the formation of new bone at sites deficient in bone volume. Another objective is to treat fenestrations and dehiscence at implant surfaces as well as defects associated with simultaneous implant placement. GBR has allowed for placement of restorations at a more ideal location in the oral cavity, thus improving esthetics and functions. This study aimed to improve the alveolar ridge width by using of synthetic bone substitute covered by resorbable collagen membrane in simultaneous dental implants placement and to compare the ridge width at three levels (crestal, middle and apical) clinically (osteometer) and radiographically (CT) pre operatively and postoperatively. Materials and methods: This prospective study was conducted in teaching dental hospital in College of Dentistry of Baghdad University on (15) patients with (21) dental implant with insufficient bony support for simultaneous dental implants , this study extended from March 2013 to the end of December 2013. All patients were treated at the time of implantation by using a synthetic bone substitute covered by resorbable collagen membrane .All patients examined clinically by osteometer and radio graphics (CT) to assess ridge width and height and bone density. Results: Clinically and radiographically evaluation showed increasing of ridge width after 6 months of healing period at three levels: apical, middle and crestal, statistically, there were no significant differences between ridge width gain measured clinically and radio graphically and gender and age groups. In this study the success rate (95.24) % in (20) dental implant and only (1) dental implant was failed (4.76) % at age 47 years old. Conclusion: There was significant increase in ridge volume that augmented at the time of implantation to become sufficient width for support implant esthetically and functionally. This study revealed that there was no effect in gender and age on bone augmentation with synthetic bone substitute. Keywords: GBR, Simultaneous dental implant, osteometer, CT, ridge width and height and bone density.
Background: Studying and investigating the transverse strength(Ts), impact strength(Is), hardness (Hr) and surface roughness(Ra) of conventional and modified autopolymerizing acrylic resin with different weight percentages of biopolymer kraftlignin, after curing in different water temperatures; 40°C and 80°C. Material and Methods: Standard acrylic specimens were fabricated according to ADA specification No.12 for transverse strength, ISO 179 was used for impact testing, Shore D for hardness and profilometerfor surface roughness. The material lignin first dispersed in the monomer, then the powder PMMA is immediately added. Ligninadded in different weight percentages. Then cured using pressure pot (Ivomet) in two temperatures;40°C a
... Show MoreABSTRACT Background: Color changes that are detectable to human eye can affect the esthetic appearance of ceramic veneers. The purpose of this study was to evaluate and compare the effect of artificial accelerated aging on the color of ceramic veneers cemented with different resin cements. Materials and Methods: Sixty discs were prepared with 0.5 mm thickness, 30 discs made from IPS e.max press (Ivoclar Vivadent) and 30 discs were made from VITA Enamic (VITA Zahnfabrik). The discs were cemented with three resin cements: Variolink Veneer MV 0 shade (Ivoclar Vivadent), Rely X veneer Translucent shade (3M ESPE) and NX3 Nexus Clear shade (Kerr Corporation) with 0.1 mm thickness. The spectrophotometer Easyshade Advance was used to measure the co
... Show MoreAPFS Mohammed, 2014
This paper presents experimental results regarding the behaviours of eight simply supported partially prestressed concrete beams with internally unbonded tendons, focusing particularly on the effect of three different variables: concrete compressive strength,
Background: One of the drawbacks of vital teeth bleaching is color stability. The aim of the present study was to evaluate the effects of tea and tomato sauce on the color stability of bleached enamel in association with the application of MI Paste Plus (CPP-ACPF). Materials and Methods: Sixty enamel samples were bleached with 10% carbamide peroxide for two weeks then divided into three groups (A, B and C) of 20 samples each. After bleaching, the samples of each group were subdivided into two subgroups (n=10). While subgroups A1, B1 and C1 were kept in distilled water, A2, B2, and C2 were treated with MI Paste Plus. Then, the samples were immersed in different solutions as follow: A1 and A2 in distilled water (control); B1 and B2 in black
... Show More
Objectives Dental implant is a revolution in dentistry; some shortages are still a focus of research. This study use long duration of radiofrequency (RF)–magnetron sputtering to coat titanium (Ti) implant with hydroxyapatite (HA) to obtain a uniform, strongly adhered in a few micrometers in thickness. Materials and Methods Two types of substrates, discs and root form cylinders were prepared using a grade 1 commercially pure (CP) Ti rod. A RF–magnetron sputtering device was used to coat specimens with HA. Magnetron sputtering was set at 150 W for 22 hours at 100°C under continuous argon gas flow and substrate rotation at 10 rpm. Coat properties were evaluated via field emission scanning electron microscopy (FESEM), scanning electro
... Show MoreThe research aims to reveal the methods of visual intertextuality used in the websites of the oriented satellite channel which is Arabic-speaking when addressing normalization with Israel. It also indicates the sources and types of intertextual images, the methodological and semiotic mechanisms for analyzing the intertextuality of news images used on the website of Alhurra satellite channel for the period from 1/6 - 30/8/2022, which included (94) images. The researcher analyzed (37) images with intertextual dimensions, excluding (57) images, which did not carry connotations connected with the inputs and objectives of the research.
The research reach
... Show More