Background: Simultaneous and staged guided bone regeneration (GBR) is one of the several surgical techniques that have been developed in the past two decades to regenerate bone and thus to allow implant placement in compromised sites (fenestration and dehiscence). It is a surgical procedure that consists of the placement of a cell-occlusive physical barrier between the connective tissue and the alveolar bone defect. The treatment concept advocates that regeneration of osseous defects is predictably attainable via the application of occlusive membranes, which mechanically exclude non-osteogenic cell populations from the surrounding soft tissues, thereby allowing osteogenic cell populations originating from the parent bone to inhabit the osseous wound. Augmentation utilizing guided bone regeneration (GBR) has become a major treatment option to provide optimal bone to support Osseointegrated dental implants. One of the objectives of GBR is the formation of new bone at sites deficient in bone volume. Another objective is to treat fenestrations and dehiscence at implant surfaces as well as defects associated with simultaneous implant placement. GBR has allowed for placement of restorations at a more ideal location in the oral cavity, thus improving esthetics and functions. This study aimed to improve the alveolar ridge width by using of synthetic bone substitute covered by resorbable collagen membrane in simultaneous dental implants placement and to compare the ridge width at three levels (crestal, middle and apical) clinically (osteometer) and radiographically (CT) pre operatively and postoperatively. Materials and methods: This prospective study was conducted in teaching dental hospital in College of Dentistry of Baghdad University on (15) patients with (21) dental implant with insufficient bony support for simultaneous dental implants , this study extended from March 2013 to the end of December 2013. All patients were treated at the time of implantation by using a synthetic bone substitute covered by resorbable collagen membrane .All patients examined clinically by osteometer and radio graphics (CT) to assess ridge width and height and bone density. Results: Clinically and radiographically evaluation showed increasing of ridge width after 6 months of healing period at three levels: apical, middle and crestal, statistically, there were no significant differences between ridge width gain measured clinically and radio graphically and gender and age groups. In this study the success rate (95.24) % in (20) dental implant and only (1) dental implant was failed (4.76) % at age 47 years old. Conclusion: There was significant increase in ridge volume that augmented at the time of implantation to become sufficient width for support implant esthetically and functionally. This study revealed that there was no effect in gender and age on bone augmentation with synthetic bone substitute. Keywords: GBR, Simultaneous dental implant, osteometer, CT, ridge width and height and bone density.
This article aim to estimate the Return Stock Rate of the private banking sector, with two banks, by adopting a Partial Linear Model based on the Arbitrage Pricing Model (APT) theory, using Wavelet and Kernel Smoothers. The results have proved that the wavelet method is the best. Also, the results of the market portfolio impact and inflation rate have proved an adversely effectiveness on the rate of return, and direct impact of the money supply.
Abstract Background: Dne of the key component of nasal tipplasty is effecter control of naral tip projection. Several cartilage grafts have been decreased for this purpose each had its own advantage and disadvantage. Aim: To evaluate using of double teostrut graft for controlling of tip projection. Patients and Methods: A total number of 170 patients were subjected to primary and secondary rhino plaster between January 2020 to January 2023. Those patients had double Teostrut banner graft for support of their nasal tip and maintaining tip projection after operation. Results: The follow period was ranging between 6-12 months. The shape of the nose was evaluating by patents vernal analogues scale. The average score for patients satisfaction wa
... Show MoreThe physical and morphological characteristics of porous silicon (PS) synthesized via gas sensor was assessed by electrochemical etching for a Si wafer in diluted HF acid in water (1:4) at different etching times and different currents. The morphology for PS wafers by AFM show that the average pore diameter varies from 48.63 to 72.54 nm with increasing etching time from 5 to 15min and from 72.54 to 51.37nm with increasing current from 10 to 30 mA. From the study, it was found that the gas sensitivity of In2O3: CdO semiconductor, against NO2 gas, directly correlated to the nanoparticles size, and its sensitivity increases with increasing operating temperature.
Due to the large population of motorway users in the country of Iraq, various approaches have been adopted to manage queues such as implementation of traffic lights, avoidance of illegal parking, amongst others. However, defaulters are recorded daily, hence the need to develop a mean of identifying these defaulters and bring them to book. This article discusses the development of an approach of recognizing Iraqi licence plates such that defaulters of queue management systems are identified. Multiple agencies worldwide have quickly and widely adopted the recognition of a vehicle license plate technology to expand their ability in investigative and security matters. License plate helps detect the vehicle's information automatically ra
... Show More