Preferred Language
Articles
/
jbcd-648
Effect of systemic administration of Simvastatin on dental implant stability: A random clinical study
...Show More Authors

Background: the primary objective for many researches carried out in dental implantology was to reduce the period needed for functional implant loading, simvastatin (cholesterol lowering medication) had many pleiotropic effects, one of which was increasing bone density around titanium implants (1) and subsequently establishing faster osseointegrated dental implants (2,3). This study aims to reduce the period of time needed to establish secondary stability of dental implant measured in ISQ (Implant Stability Quotient) by investigating the effect of orally administered simvastatin on bone. Materials and methods: simvastatin tablets (40mg/day for three months) were administered orally for 11 healthy women aged (40-51) years old who received 15 dental implants (Dentium, Implantium) in the traumatic functional implant zone(4), this is the intervention group, the control group (n=11) received 14 dental implants in the same zone. 3 dental implants in 2 subjects were lost, leaving a total of 26 dental implants in 20 patients with 10 patients in each group. All subjects were radiographed with OPG for preliminary assessment and with CT scan for registering bone density in Hounsfield Units. Different dental implant sizes were used according to optimal patients' needs. an informed consent was obtained from the intervention group and the recommended monitoring protocol was followed. Dental implant stability ISQ were recorded using RFA by OsstellTM ISQ for both groups three times: immediately after implant placement (at surgery) and after 8,12 weeks respectively. Results: results showed that the mean implant stability for the intervention group was significantly higher P= 0.01 after 12 weeks in comparison to that of the control group. Simvastatin showed statistically significant effect on implant stability among the intervention group after 8 and 12 weeks (P value for both times <0.001) with the attributed risk percent was 70.8 and 50 respectively. Conclusions: this study concluded that the intervention group had higher implant stability and was ready for functional loading prior to control group and that simvastatin might enhanced and/or accelerated the process of osseointegration. Keywords: Implant stability, Simvastatin, resonance frequency analysis.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Dec 28 2023
Journal Name
The Iraqi Journal Of Veterinary Medicine
Resveratrol Administration Ameliorates Hepatotoxicity in Mercuric Chloride-‎Induced Liver Injury in Rats
...Show More Authors

Mercuric chloride (HgCl2) pollution and poisoning has been a worldwide health ‎concern for decades, especially after the industrial revolutions. The aim of this study ‎was to investigate the role of resveratrol in reversing the deleterious effects of ‎HgCl2 exposure to resume the normal functions of hepatocyte. To achieve the study, ‎mature Sprague Dawley rats were assigned to five groups. Negative control group ‎‎(C) kept without any treatment; vehicle-treated group (D) received dimethyl ‎sulfoxide (DMSO); resveratrol-treated group (R), received 100 mg/kg of resveratrol; ‎HgCl2-intoxicated group (HD), received i.p. injection of HgCl2 at a dose of 1 mg/kg ‎for 30 consecutive days along to oral gavage of DMSO; and finally H

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (3)
Scopus Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Journal Of Animal Health And Production
Resveratrol Administration Reverses the Endometriosis-Mediated Outcomes via Tgfβ Signaling in Rats
...Show More Authors

View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Mon May 01 2023
Journal Name
Journal Of Engineering
The Leaching Behavior of Zinc Oxide in Medical Waste of Dental Clinics
...Show More Authors

Zinc Oxide is an indispensable substance in the field of dental treatment. It is used daily and intensively in all governmental and private dental clinics, leading to the disposal of very high concentrations of zinc with waste and eventually in landfill sites as a final destination for solid waste removal. This indicates the urgent need to investigate its behavior upon disposal due to the surrounding conditions. Approximately 4195 g of mixed dental waste samples were collected from (17) healthcare centers in Baghdad Al-Karkh. The leaching behavior of ZnO powder was investigated through batch reactors using makeup dental solid waste samples. The ZnO leaching was tested with 3 conditions; acidic, alkaline, and Ionic Streng

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Dec 29 2017
Journal Name
Al-khwarizmi Engineering Journal
Design And Implementation of Microcontroller Based Curing Light Control of Dental System.
...Show More Authors

In this paper, a microcontroller-based electronic circuit have been designed and implemented for dental curing system using 8-bit MCS-51 microcontroller. Also a new control card is designed while considering advantages of microcontroller systems the time of curing was controlled automatically by preset values which were input from a push-button switch. An ignition based on PWM technique was used to reduce the high starting current needed for the halogen lamp. This paper and through the test result will show a good performance of the proposed system.

 

 

View Publication Preview PDF
Publication Date
Fri Oct 01 2021
Journal Name
Nonlienear Optics Quantum Optics
Narrow Emission Linewidth of Highly-Pure Silicon Nitride Nanoparticles in Different Dye Solutions as Random Gain Media
...Show More Authors

In this work, two different laser dye solutions were used to host highly-pure silicon nitride nanoparticles as scattering centers to fabricate random gain media. The laser dye was dissolved in three different solvents (ethanol, methanol and acetone) and the final results were obtained for methanol only. The silicon nitride nanoparticles were synthesized by dc reactive magnetron sputtering technique with average particle size of 35 nm. The random gain medium was made as a solid rod with high spectral efficiency and low production cost. Optical emission with narrow linewidth was detected at 532-534 nm as 9 mg of silicon nitride nanoparticles were added to the 10 -5 M dye solution. The FWHM of 0.3 and 3.52 nm was determined for Rhodamine B and

... Show More
View Publication
Publication Date
Tue Feb 17 2026
Journal Name
Sustainable Engineering And Innovation
Morlet wavelet–based olfactory-evoked EEG features for random forest classification of normal, aMCI, and Alzheimer’s disease
...Show More Authors

Olfactory impairment and abnormal frontal EEG oscillations are recognized as early markers of Alzheimer’s disease (AD). Using a publicly available olfactory EEG dataset of 35 subjects spanning normal cognition, amnestic mild cognitive impairment (aMCI), and AD, each with MMSE scores and demographics, stimulus-locked epochs from four electrodes (Fp1, Fz, Cz, Pz) were processed with wavelet-based time–frequency analysis. Band-limited power ratios (delta, theta, alpha, beta) were computed as log-transformed post-odor/baseline values and aggregated to subject-level features. Statistical analyses revealed graded attenuation of odor-evoked frontal (Fp1) band-power ratios across groups, with significant differences in several band–od

... Show More
View Publication
Scopus Crossref
Publication Date
Fri Jul 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
Comparison some of methods wavelet estimation for non parametric regression function with missing response variable at random
...Show More Authors

Abstract

 The problem of missing data represents a major obstacle before researchers in the process of data analysis in different fields since , this problem is a recurrent one in all fields of study including social , medical , astronomical and clinical experiments .

The presence of such a problem within the data to be studied may influence negatively on the analysis and it may lead to misleading conclusions , together with the fact that these conclusions that result from a great bias caused by that problem in spite of the efficiency of wavelet methods but they are also affected by the missing of data , in addition to the impact of the problem of miss of accuracy estimation

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 05 2011
Journal Name
Baghdad Science Journal
Study the Effect of Scattering and Disperse Radiation on Equivalent Dose Rate for Al & Pb Shields
...Show More Authors

The effects of scattering and secondary radiation generated inside the material on dose equivalent rate where studied using Co60 and Cs137 sources of activity (199.8 , 177.6) MBq , respectively for different thicknesses of Al , Pb and Pb- glass . The results showed that the equivalent rate increases when the effect of scattering was included for Al and Pb shields with cobalt-60 source of energy 1.25 MeV ; and decreases for Pb shield with Cs-137 source of energy 0.662MeV .The results showed also that the atomic number of The material effects the dose equivalent rate . The Pb-glass shield was found to be more efficient in absorption than other shields.

View Publication Preview PDF
Crossref
Publication Date
Fri Sep 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluating the effect of natural, industrial juices and beverage on orthodontic bonding composite (in-vitro study)
...Show More Authors

Background: Dental erosion is a common oral condition which results due to consumption of high caloric and low pH acidic food such as carbonated drinks and fruit juices. It is expected that these food types can cause irreversible damage to dental hard tissues and early deterioration of the dental restorations. So, this study aimed to evaluate and compare the erosive potential effects of orange fruit juice and Miranda orange drink on the microhardness of an orthodontic composite material. Materials and methods: Thirty discs with a thickness of 2 mm and a diameter of 10 mm were prepared from orthodontic bonding composite. The prepared discs were equally divided into three groups (n=10). Microhardness analysis was carried out both prior to

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Pakistan Journal Of Medical And Health Sciences
The Effect of Music Therapy on Clients' Vital Signs during Pulmonary Function Test: An Experimental Study
...Show More Authors

Background: The patient's vital signs must stay stable pre a pulmonary function test since the approach demands the patient to breathe slowly and deeply and exhale quickly. However, events that cause variations in normal vital signs may impact the patient. Many strategies can be utilized to stabilize vital signs, including music treatment. The purpose of this study is to compare the effectiveness of music therapy on the vital signs of client's pre a pulmonary function test. Methods: An experimental design study with an application (pre-test, post-test), to determine the effectiveness of music therapy for clients pre pulmonary function test for 106 clients in Al-Diwaniyah, Al-Shamiya, and Al- Hamza public hospitals In Iraq. Parti

... Show More
View Publication
Crossref