Background: the primary objective for many researches carried out in dental implantology was to reduce the period needed for functional implant loading, simvastatin (cholesterol lowering medication) had many pleiotropic effects, one of which was increasing bone density around titanium implants (1) and subsequently establishing faster osseointegrated dental implants (2,3). This study aims to reduce the period of time needed to establish secondary stability of dental implant measured in ISQ (Implant Stability Quotient) by investigating the effect of orally administered simvastatin on bone. Materials and methods: simvastatin tablets (40mg/day for three months) were administered orally for 11 healthy women aged (40-51) years old who received 15 dental implants (Dentium, Implantium) in the traumatic functional implant zone(4), this is the intervention group, the control group (n=11) received 14 dental implants in the same zone. 3 dental implants in 2 subjects were lost, leaving a total of 26 dental implants in 20 patients with 10 patients in each group. All subjects were radiographed with OPG for preliminary assessment and with CT scan for registering bone density in Hounsfield Units. Different dental implant sizes were used according to optimal patients' needs. an informed consent was obtained from the intervention group and the recommended monitoring protocol was followed. Dental implant stability ISQ were recorded using RFA by OsstellTM ISQ for both groups three times: immediately after implant placement (at surgery) and after 8,12 weeks respectively. Results: results showed that the mean implant stability for the intervention group was significantly higher P= 0.01 after 12 weeks in comparison to that of the control group. Simvastatin showed statistically significant effect on implant stability among the intervention group after 8 and 12 weeks (P value for both times <0.001) with the attributed risk percent was 70.8 and 50 respectively. Conclusions: this study concluded that the intervention group had higher implant stability and was ready for functional loading prior to control group and that simvastatin might enhanced and/or accelerated the process of osseointegration. Keywords: Implant stability, Simvastatin, resonance frequency analysis.
This study aims to analyze the spectral properties of plasma produced from rice husk(Rh) using the laser breakdown spectroscopy (LIBS) method. The plasma generation process used the fundamental harmonic (1064 nm) of a Q-switched Nd:YAG laser. Yttrium aluminum garnet (YAG) is a man-made crystalline material. The laser fired pulses with a duration of 10 ns and a repetition rate of 6 Hz. Thus, the energy outputs achieved were 50–200 mJ at the wavelength of 1064 (nm). The silica content in the rice hulls was verified using an XRF measurement, which revealed the presence of silica in the rice hulls in a high percentage. Precise beam focusing was achieved by focusing the laser on the target material. This target material is placed with
... Show Moreيعد علم التدريب الرياضي الحديث عملية تربوية علمية مبنية على اسس صحيحة هدفها وصول اللاعبين الى التكامل في الاداء الفني وهذا يتم عن طريق التأثير المنظم والدقيق بواسطة استعمال التمارين البدنية التي تحدث تغيرات خاصة في عمل اعضاء واجهزة جسم الرياضي والتي بدورها تؤدي الى رفع كفاءة الاعضاء والاجهزة لتحقيق الانجازات الرياضية العالية ولقد استعملت الباحثتان اسلوب حديث من اساليب التدريب الرياضي من اجل تطوير تحم
... Show MoreObjective: To enhance bonding strength between thermoplastic denture base and acrylic soft liner through ethyl acetate surface treatment. Materials and Methods: Modifications of thermoplastic acrylic denture base surface were investigated with SEM. FTIR was used to detect whether there was a chemical bond between thermoplastic acrylic and the organic solvent. A total of 80 samples were prepared and divided into 20 samples for the surface roughness test and 60 samples for the shear bond strength test. Failure type was assessed visually. Results: Shear bond strength and surface roughness values of un treated samples were lower in comparison to surface treated groups; the greatest post thermocycling bond strength value was recorded for the sam
... Show MoreBackground: The clinical examination is one of the best suitable methods for diagnosis of low backache. Backache is one disease that the signs, clinical examination finding, and the results on imaging modalities not always related. The straight leg raising (SLR) and slump tests, can be used for diagnosis of lumber disc herniation.
Objectives: To compare the result of the slump test and SLR test in the diagnosis of lumber disc herniation.
Subjects and Methods: A prospective comparative study conducts on 280 patients in Al-Kindy teaching and private clinics complaints of backache, aging between 18-70 years old with acute or recurrent backache, sciatica pai
... Show MoreThis paper presents ABAQUS simulations of fully encased composite columns, aiming to examine the behavior of a composite column system under different load conditions, namely concentric, eccentric with 25 mm eccentricity, and flexural loading. The numerical results are validated with the experimental results obtained for columns subjected to static loads. A new loading condition with a 50 mm eccentricity is simulated to obtain additional data points for constructing the interaction diagram of load-moment curves, in an attempt to investigate the load-moment behavior for a reference column with a steel I-section and a column with a GFRP I-section. The result comparison shows that the experimental data align closely with the simulation
... Show MoreThis study compared in vitro the microleakage of a new low shrink silorane-based posterior composite (Filtek™ P90) and two methacrylate-based composites: a packable posterior composite (Filtek™ P60) and a nanofill composite (Filtek™ Supreme XT) through dye penetration test. Thirty sound human upper premolars were used in this study. Standardized class V cavities were prepared at the buccal surface of each tooth. The teeth were then divided into three groups of ten teeth each: (Group 1: restored with Filtek™ P90, Group 2: restored with Filtek™ P60, and Group 3: restored with Filtek™ Supreme XT). Each composite system was used according to the manufacturer's instructions with their corresponding adhesive systems. The teeth were th
... Show MoreComics is a visual art (Still and motion pictures) it seeks to provide a Training courses are a series of intensive important educational and complementary programs, based on previous foundation experiences. Create to development the participants in aspects of specialization according to the requirements of the educational system to continue developing the previous scientic and practical experiences. Personally, or adopted by the trainee institution, where the trainee gets a professional skill certicate that contributes to the development his work.Development and Continuous Education Center (DCEC) at the University of Baghdad (UoBaghdad) is a center dedicated to continuing education courses in which the participant is awarded a cert
... Show MoreBackground: The aim of this study was to evaluate and compare the apical microleakage around retrograde cavities prepared with ultrasonic technique and filled with (Biodentineâ„¢) Materials and methods: 40 extracted single rooted human permanent maxillary teeth with mature apices were selected. The roots were prepared chemo-mechanically using k-files with crown-down technique and then obturated with lateral condensation gutta-percha technique. Teeth were divided into four main groups according to the cavity preparation method either manual or ultrasonic technique: Group A (n=10): A class I retrograde cavity at root end was prepared with traditional handpeice equipped and placement of Biodentine with manual condensation. Group B (n=10):
... Show More