Preferred Language
Articles
/
jbcd-648
Effect of systemic administration of Simvastatin on dental implant stability: A random clinical study
...Show More Authors

Background: the primary objective for many researches carried out in dental implantology was to reduce the period needed for functional implant loading, simvastatin (cholesterol lowering medication) had many pleiotropic effects, one of which was increasing bone density around titanium implants (1) and subsequently establishing faster osseointegrated dental implants (2,3). This study aims to reduce the period of time needed to establish secondary stability of dental implant measured in ISQ (Implant Stability Quotient) by investigating the effect of orally administered simvastatin on bone. Materials and methods: simvastatin tablets (40mg/day for three months) were administered orally for 11 healthy women aged (40-51) years old who received 15 dental implants (Dentium, Implantium) in the traumatic functional implant zone(4), this is the intervention group, the control group (n=11) received 14 dental implants in the same zone. 3 dental implants in 2 subjects were lost, leaving a total of 26 dental implants in 20 patients with 10 patients in each group. All subjects were radiographed with OPG for preliminary assessment and with CT scan for registering bone density in Hounsfield Units. Different dental implant sizes were used according to optimal patients' needs. an informed consent was obtained from the intervention group and the recommended monitoring protocol was followed. Dental implant stability ISQ were recorded using RFA by OsstellTM ISQ for both groups three times: immediately after implant placement (at surgery) and after 8,12 weeks respectively. Results: results showed that the mean implant stability for the intervention group was significantly higher P= 0.01 after 12 weeks in comparison to that of the control group. Simvastatin showed statistically significant effect on implant stability among the intervention group after 8 and 12 weeks (P value for both times <0.001) with the attributed risk percent was 70.8 and 50 respectively. Conclusions: this study concluded that the intervention group had higher implant stability and was ready for functional loading prior to control group and that simvastatin might enhanced and/or accelerated the process of osseointegration. Keywords: Implant stability, Simvastatin, resonance frequency analysis.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
International Journal Of Advanced Research
ON STABILITY AND THE BOUNDEDNESS OF THE ZERO SOLUTION OF FIFTH ORDER
...Show More Authors

This paper is illustrates the sufficient conditions of the uniformly asymptotically stable and the bounded of the zero solution of fifth order nonlinear differential equation with a variable delay τ(t)

Publication Date
Thu Apr 30 2020
Journal Name
Journal Of Economics And Administrative Sciences
Econometrics of the impact of financial inclusion on banking stability in Iraq
...Show More Authors

        Financial inclusion refers to the access of financial services at low cost and high-quality from the formal financial sector to all segments of society, especially marginalized groups, and then use and benefit from them. Financial inclusion is also associated with banking stability, as well as with financial integrity and financial protection for the consumer, therefore, it achieves a number of objectives, the most important of which is to support and enhance banking stability. This is what made it attract the attention of many countries and central banks recently.

     The study aims to show the impact of financial inclusion indicators on ban

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Jul 20 2021
Journal Name
Polymer Bulletin
Influence methods of preparation on the thermal stability of polyimide/silica dust
...Show More Authors

View Publication
Scopus (33)
Crossref (29)
Scopus Clarivate Crossref
Publication Date
Thu May 31 2012
Journal Name
Al-khwarizmi Engineering Journal
An Experimental Study on the Effect of Shape and Location of Vortex Generators Ahead of a Heat Exchanger
...Show More Authors

An experimental study is carried out on the effect of vortex generators (Circular and square) on the flow and heat transfer at variable locations at (X = 0.5, 1.5, 2.5 cm) ahead of a heat exchanger with Reynolds number ranging from 62000< Re < 125000 and heat flux from 3000 ≤ q ≤ 8000 W/m2 .

In the experimental investigation, an apparatus is set up to measure the velocity and temperatures around the heat exchanger.                     

The results show that there is an effect for using vortex generators on heat transfer. Also, heat transfer depends on the shape and location. The circular is found t

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 01 2009
Journal Name
Ipmj
Perniosis: Clinical and epidemiological study in Iraqi patient
...Show More Authors

A Al-Nuaimy, B Fadheel…, IPMJ, 2009 - Cited by 1

View Publication
Publication Date
Thu Oct 01 2009
Journal Name
Journal
Perniosis: clinical and epidemiological study in Iraqi patients
...Show More Authors

AN Adil A, F Basman M, 2009

View Publication
Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Cosmetics, Dermatological Sciences And Applications
Pityriasis Alba versus Vitiligo Clinical and Histopathological Study
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Sat Dec 30 2023
Journal Name
Al-mustansiriyah Journal Of Science
Study of Phenotypic and Genotypic Factors of Staphylococcus aureus Clinical Local Isolates
...Show More Authors

The isolates of Staphylococcus aureus were isolated from patients with various infections in hospitals, the isolates were identified and accurately diagnosed by phenotypic examination and biochemical tests, as well Vitek-2, and then genetic detection and diagnosis of many of the pathogenic factors associated with Staphylococcus aureus using conventional polymerase chain reaction (PCR) and testing for association by antibiotic resistance and production of some toxins by Staphylococcus aureus. After performing analysis of statistical, it was set up that the correlation coefficient of the PCR technique using virulence genes, sensitivity test to antibiotics and other virulence factors were significant at p < 0.05, but was insignificant with the

... Show More
View Publication
Publication Date
Thu Apr 01 2021
Journal Name
Iraqi Journal Of Applied Physics
Effects of Solvent Properties on Absorption and Fluorescence Characteristics of Two Organic Dyes Used as Random Gain Media
...Show More Authors

In this work, the effects of solvent properties on the characteristics of absorption and fluorescence for two laser dyes was studied. Dyes used in this work include Coumarin 5400 and DCM, while the solvents include ethanol, methanol, acetone, propanol and chloroform. Coumarin 5400 dye shows sharp fluorescence peaks in the green band of visible region while the DCM dye shows relatively wide band within 590-630 nm. Therefore, the selection of any dye for random gain medium applications should be performed after determining the most appropriate solvent as the optimum fluorescence characteristics are obtained.

View Publication Preview PDF
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
A Survey of Prosthodontics Techniques Applied by Dental Practitioners in Sulaimani City
...Show More Authors

Background: Prosthodontic services have changed markedly due to an introduction of new materials, techniques and treatment options. The aim of this study were to identify the type of materials and the methods used by dental practitioners in their clinics to construct conventional complete dentures and to specify the type and design for removable partial dentures (RPDs); and to then compare them with those taught in dental schools. Materials and methods: A total of 153 dental practitioners in Sulaimani city completed a written questionnaire. The questionnaire included 19 questions regarding complete and RPDs fabrication. Results: Most of the practitioners provide complete dentures (81.6%) and RPDs (95.3%) in their clinics. Polyvinyl silox

... Show More
View Publication Preview PDF
Crossref (2)
Crossref