Preferred Language
Articles
/
jbcd-635
An evaluation of the influence of different finishing lines on the fracture strength of full contour zirconia CAD/CAM and heat press all-ceramic crowns
...Show More Authors

ABSTRACT Background: One of the major problems of all ceramic restorations is their probable fracture against the occlusal forces. The objective of this in vitro study was to evaluate the effect of two gingival finishing lines (90°shoulder and deep chamfer) on the fracture resistance of full contour CAD/CAM and heat press all-ceramic crowns. Materials and Methods: Thirty two maxillary first premolars were prepared to receive full contour CAD/CAM (zolid) and heat press (Cergo Kiss) ceramic crowns using a special paralleling device (Parallel-A-Prep). The teeth were divided into four groups according to the type of finishing line prepared. Each crown was cemented to its corresponding tooth using self-etch, self-adhesive dual cure resin cement. Following storage for 1 week in distilled water at room temperature, teeth were subjected to thermal cycling. Fracture resistance was determined using a universal testing machine, and the samples were investigated microscopically from the point of view of the origin of the failure. Statistical analysis was carried out using the one-way ANOVA and Student’s t-tests. Results: The mean values of fracture resistance for CAD/CAM group showed 1367.250+178.967 N for 90°shoulder margins and 1109.250+252.455 N for the deep chamfer margins. ANOVA test results revealed high significance between and within the groups. The mean values of fracture resistance for heat press group were 548.562+272.471 N for 90°shoulder margins and 247.912+96.995 N for the deep chamfer margins expressing statistical significance. Conclusions: The results of this study pointed to a relationship between the design of the cervical finishing line and the fracture strength of the full CAD/CAM crowns and the full heat press ceramic crowns. Both 90° shoulder and deep chamfer finishing lines are suitable for zolid crowns while the 90° shoulder is more suitable for the Cergo Kiss crowns than the deep chamfer preparation. Key words: Full contour, All-ceramic crowns, CAD/CAM, Heat press, Fracture strength.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Sep 04 2015
Journal Name
International Journal Of Academic Research In Progressive Education And Development
The Influence of Three Teaching Methods on Undergraduate Physics Students' Group Work Skill
...Show More Authors

The purpose of this study is to compare the influence of three teaching methods, as represented by problem-based learning (PBL), the PBL with lecture method, and the conventional teaching on undergraduate physics students' group work skills among bachelor’s degree physics students. In this study, the pre- and post-test were done and the instruments were administered to the students for data collection. The actual sample size comprises of 122 students, who were selected randomly from the physics department, college of education in iraq. Overall, the statistical results rejected null hypothesis of this study. Thus, using the PBL without or with lecture method enhances the skills of the group work among the bachelor’s degree physics studen

... Show More
Publication Date
Sun Oct 01 2023
Journal Name
Nanomedicine Research Journal
The effect of ZrO2 NPs addition on denture adaptation and diametral compressive strength of 3D printed denture base resin
...Show More Authors

Objective(s): The world of dentistry is constantly evolving, and with the advent of 3D printing technology, the possibilities are endless. However, little is known about the effects of adding ZrO2 NPs to the denture base resin of 3D additive manufacturing technique.Aim of this study is to evaluate the behavior of resin which is used to 3D printing of denture base with the addition of ZrO2 NPs on denture adaptation property and diametral compression strength.Methods: 60 samples were printed, 30 disks for diametral compressive test and 30 denture base for denture adaptation test. Three groups per test (n=10). The control group for each test included unreinforced 3Dprinted denture base resin, and the other groups were  reinforced with (2&

... Show More
View Publication
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Engineering
The Response of Some Properties of (Al-Si-Mg) Alloy to Nano-Ceramic Materials’ Addition
...Show More Authors

Al-Si alloys which are widely used in engineering applications due to their outstanding properties can be modified for more enhancements in their properties. Current work investigated the ability of these alloys to be modified by casting them through the addition of nanoparticles. So, Multi-wall carbon nanotubes (CNT) and titanium carbide ceramic particles (TIC) with size of (20 nm) were added with different amounts started from (0.5 up to 3%) weight  to cast alloy A356 that was considered to be the base metal matrix, then stirred with different speeds of (270, 800, 1500, 2150) rpm at 520 °C for one minute. The results showed change in microstructure’ shape of the casted alloys from the dendritic to spherical gra

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Aug 01 2017
Journal Name
Journal Of Multidisciplinary Engineering Science And Technology (jmest)
Study The Influence Of Sn Dopant On The Surface Topography And Some Physical Properties Of CdSe Films Prepared By Evaporation Technique
...Show More Authors

Publication Date
Tue Sep 19 2017
Journal Name
Al-academy
Technology manufacturing Ghazi oven and sessile cost of production of ceramic
...Show More Authors

The ceramic work of the business that was stationed with the history of its evolution of man on earth, and this gives him a linking formula and the reality of life, including asking as inherited civilized . Operation creativity over several stages and developments have helped in the formation of human hands, including a reflection on productions are large and diverse.

To search for new horizons in ceramic art began to form new technologies outside the traditional frameworks ,devoted  technical and scientific expertise and access to an advanced stage in porcelain from technical and aesthetic point of view the field, shall be deemed to contemporary ceramic civilized idea of ​​Modernism from the ceramic work can in no way b

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Parametric Study of Mixed Convective Radiative Heat Transfer in an Inclined Annulus
...Show More Authors

The steady state laminar mixed convection and radiation through inclined rectangular duct with an interior circular tube is investigated numerically for a thermally and hydrodynamicaly fully developed flow. The two heat transfer mechanisms of convection and radiation are treated independently and simultaneously. The governing equations which used are continuity, momentum and energy equations. These equations are normalized and solved using the Vorticity-Stream function and the Body Fitted Coordinates (B.F.C) methods. The finite difference approach with the Line Successive Over-Relaxation (LSOR) method is used to obtain all the computational results. The (B.F.C) method is used to generate the grid of the problem. A computer program (Fortr

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Parametric Study of Mixed Convective Radiative Heat Transfer in an Inclined Annulus
...Show More Authors

The steady state laminar mixed convection and radiation through inclined rectangular duct with an interior circular tube is investigated numerically for a thermally and hydrodynamicaly fully developed flow. The two heat transfer mechanisms of convection and radiation are treated independently and simultaneously. The governing equations which used are continuity, momentum and energy equations. These equations are normalized and solved using the Vorticity-Stream function and the Body Fitted Coordinates (B.F.C) methods. The finite difference approach with the Line Successive Over-Relaxation (LSOR) method is used to obtain all the computational results. The (B.F.C) method is used to generate the grid of the problem. A computer program (Fortran

... Show More
Publication Date
Wed Jan 01 2020
Journal Name
International Journal Of Mathematical Modelling And Numerical Optimisation
Reconstruction of an orthotropic thermal conductivity from non-local heat flux measurements
...Show More Authors

View Publication
Scopus (9)
Crossref (1)
Scopus Crossref
Publication Date
Fri Jan 03 2020
Journal Name
Chalcogenide Letters
THE EFFECT OF Ag CONTENT AND HEAT TREATMENT ON STRUCTURAL AND MORPHOLOGICAL PROPERTIES OF THIN (Cu1-xAgx)2 ZnSnSe4 FILMS
...Show More Authors

(Cu1-x,Agx)2ZnSnSe4 alloys have been fabricated with different Ag content(x=0, 0.1, and 0.2) successfully from their elements. Thin films of these alloys have been deposited on coring glass substrate at room temperature by thermal evaporation technique under vacuum of 10-5Torr with thickness of 800nm and deposition rate of 0.53 nm/sec. Later, films have been annealed in vacuum at (373, and 473)K, for one hour. The crystal structure of fabricated alloys and as deposited thin films had been examined by XRD analysis, which confirms the formation of tetragonal phase in [112] direction, and no secondary phases are founded. The shifting of main polycrystalline peak (112) to lower Bragg’s angle as compared to Cu2ZnSnSe4 angle refers to incorpora

... Show More
Preview PDF
Publication Date
Sun Dec 21 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of the addition of silanized Nano titania fillers on some physical and mechanical properties of heat cured acrylic denture base materials
...Show More Authors

Background: Polymethyl methacrylate (PMMA) is the most commonly used material in denture fabrication. The material is far from ideal in fulfilling the mechanical requirement. The purpose of this study was to evaluate the effect of addition of 3% wt of treated (silanized) Titanium oxide Nano filler on some physical and mechanical properties of heat cured acrylic denture base material. Materials and methods: 100 specimens were constructed, 50 specimens were prepared from heat cure PMMA without additives (control) and 50 specimens were prepared from heat cure PMMA with the addition of TiO2 Nano fillers. Each group was divided into 5 sub groups according to the test performed which was mixed by probe ultra-sonication machine. Results: A highly

... Show More
View Publication Preview PDF