Background: It may be an important prospective clinical use of manufacturing of porous implant for clinical situations, such as cases of limitation in bone height, low bone density .The small segment of porous implant an effective osseointegration allows increasing in contact area provided for small segmented porous provided by its surface configuration. This study was done to Fabricate porous titanium implants by powder technology, as well as the observation of removal torque values of porous titanium implants compared to smooth titanium implants. Materials and methods: Twenty porous titanium implants (3.2mm in diameter and 8mm in length) were manufactured by powder technology using commercially pure titanium powder of ≤75um particles size, with polyvinyl alcohol powder of 212-300um particle size, as a space holder, by volume ratio (70:30) % respectively. The mixed powder was compacted using punch and die set -specially designed for this study –under 20 bar then sintering at 900 ºC by the use of argon gas. Twenty smooth titanium implants were prepared of (3.2mm in diameter and 8mm in length) by lathing of commercially pure titanium rod as a control group. The implants were examined by X-ray diffraction (XRD) and scanning electron microscope (SEM), as well as estimation of porosity percentage. For each tibia of the 20 white New Zealand rabbits, one implant of each type (one porous in right, and the smooth in left tibia), were inserted through surgical procedure carried under serial condition. Mechanical test was performed to evaluate the bone-implant interface, after (2 and 6 weeks) healing periods . Results: Porous implants were obtained successfully by powder technology with 52% porosity and pore size 210um 17±. The porous implant showed significantly higher removal torque values when compared to smooth implants at the two different intervals of examination (2,6 weeks) , this proved to be statistically highly significant, also a highly significant difference was noticed for the means of the torque removal values in the same group at different implantation , with no evidence of clinical features of inflammatory reaction with both . Conclusions: Powder technology seemed to be particularly advantageous in fabrication of porous titanium. Porous implant show an increasing bone ingrowth compared with the smooth type represented by higher removal torque for both healing periods (2, 6) weeks . Key words: Porous titanium implant, powder technology, removal torque test.
This paper aims to evaluate the reliability analysis for steel beam which represented by the probability of Failure and reliability index. Monte Carlo Simulation Method (MCSM) and First Order Reliability Method (FORM) will be used to achieve this issue. These methods need two samples for each behavior that want to study; the first sample for resistance (carrying capacity R), and second for load effect (Q) which are parameters for a limit state function. Monte Carlo method has been adopted to generate these samples dependent on the randomness and uncertainties in variables. The variables that consider are beam cross-section dimensions, material property, beam length, yield stress, and applied loads. Matlab software has be
... Show MoreThe aim of the research is to determine the impact of evaluating the investment projects in the development and preparation of investment budgets prepared by the economic units, since the investment projects are of an important and vital nature of the economic units, because these projects include the length of time for preparation and implementation and the accompanying period of this risk and uncertainties as well as need To the many funds to complete the project , The process of evaluating the implemented projects, which have been prepared an investment budget previously will contribute to the extent of matching the estimated data with the actual results or deviations, which is a step to avoid these errors in future p
... Show MoreObjective:To measure the acceptance level of the Personal Digital Assistance (PDA)’suse among nursing students as a tool of education in the Kingdom of Saudi Arabia. Methodology: Eighty-nine nursing students participated in this cross-sectional descriptive study by completing a questionnaire based on the Technology Acceptance Model (TAM) by Davis. Two dimensions were explored and evaluated; (1) the applicability of the TAM model in assessing this technology; and (2) the overall percentage of students’ agreement on the different TAM variables. Results: This study presented significant positive influence bet
In this work, N-hydroxy phthalimide derivatives (NHPID) were synthesized from the nucleuphilic substitution reactions of (NHPI) with different halides (alkyl halides, sulfonyl halides, benzoyl halides and benzyl halides). The products were distinguished using FTIR spectrum and Nuclear magnetic resonsnce (1H-NMR and 13CNMR), in addition to other characteristic methods such as sodium fution for sulfur determination. followed by measuring antibacterial (with different types of gram positive/gram negative bacteria) and antifungal activities of these compounds.
Objective(s): To evaluate youth's health risk behaviors in Baghdad City and to determine the relationship between such behaviors and the youth's demographic characteristics of age, gender and grade. Methodology: A descriptive study, using the evaluation approach, is carried out to evaluate youth's health risk behaviors in Baghdad City for the period of January 26th 2016 to May 20th 2016. A non-probability "purposive" sample of (160) University students is selected for the purpose of the study from four groups of colleges (medical, engineering, sciences, and education) and it is equally distributed of
The present study was designed to synthesize a number of new Ceftriaxone derivatives by its involvement with a series of different amines, through the chemical derivatization of its 2-aminothiazolyl- group into an amide with chloroacetyl chloride, which on further conjugation with these selected amines will produce compounds with pharmacological effects that may extend the antimicrobial activity of the parent compound depending on the nature of these moieties.
Ceftriaxone was first equipped with a spacer arm (linker) by the action of chloroacetyl chloride in aqueous medium and then further reacted with seven different aliphatic and aromatic amines which resulted in the production of the aimed final target products. The syntheses
... Show MoreCoumarin derivatives have shown different biological activities, such as antifungal, antibacterial antiinflammatory, and antioxidant activities, besides antibiotic resistance modulating effects, and anti-HIV, hepatoprotective, and antitumor effect. So, new coumarin derivatives (hydrazones and an amide) were synthesized through multisteps reactions. All the synthesized target compounds were characterized by FT-IR spectroscopy, 1HNMR analysis. The compounds then evaluated for their anti-bacterial activity by means of well-diffusion method against two gram-positive bacteria (Staphylococcus aureus, Streptococcus pneumoniae) and two gram-negative bacteria (E.coli and Pseudomonas aeruginosa). The highest activity was demonstr
... Show MoreAims: This study aims to compare patients’ complaints and problems of wearing complete dentures.
Methodology: The sample included 40 Iraqi patients who are wearing complete dentures from about five years ago. They
were selected randomly with a age range between (55–65) years. The questions asked to the patients were listed according
to the recent classification of post-insertion problems.
Result: The results showed that the percentage of patient's complaint from adaptation problems (62.1%) was higher than
looseness problems (61.3%) and discomfort problems (39.3%) as followed.
Recommendation: Dentists need thorough knowledge of anatomy, physiology, pathology and psychology. The assessing
of the psyche and emotions
The objective of the study was to develop microneedle (MN) patch, with suitable properties to ensure the delivery of a therapeutic level of lornoxicam (LXM) in a period suitable to replace parenteral administration in patients, especially those who fear needles. The used polymers were cold water-soluble polyvinyl alcohol (PVA) and polyvinylpyrrolidone (PVP) of low molecular weight with PEG 400 as plasticizer and Tween 80 (to enhance the release) using micro molding technique. Patches were studied for needle morphology, drug content, axial fracture force measurement and drug release while the optimized formulas were further subjected to pH measurement, folding endurance, ex vivo permeation study, histopathology study, stability study and
... Show More