Preferred Language
Articles
/
jbcd-630
Biomechanical evaluation of porous titanium implants (CpTi) fabricated by powder technology
...Show More Authors

Background: It may be an important prospective clinical use of manufacturing of porous implant for clinical situations, such as cases of limitation in bone height, low bone density .The small segment of porous implant an effective osseointegration allows increasing in contact area provided for small segmented porous provided by its surface configuration. This study was done to Fabricate porous titanium implants by powder technology, as well as the observation of removal torque values of porous titanium implants compared to smooth titanium implants. Materials and methods: Twenty porous titanium implants (3.2mm in diameter and 8mm in length) were manufactured by powder technology using commercially pure titanium powder of ≤75um particles size, with polyvinyl alcohol powder of 212-300um particle size, as a space holder, by volume ratio (70:30) % respectively. The mixed powder was compacted using punch and die set -specially designed for this study –under 20 bar then sintering at 900 ºC by the use of argon gas. Twenty smooth titanium implants were prepared of (3.2mm in diameter and 8mm in length) by lathing of commercially pure titanium rod as a control group. The implants were examined by X-ray diffraction (XRD) and scanning electron microscope (SEM), as well as estimation of porosity percentage. For each tibia of the 20 white New Zealand rabbits, one implant of each type (one porous in right, and the smooth in left tibia), were inserted through surgical procedure carried under serial condition. Mechanical test was performed to evaluate the bone-implant interface, after (2 and 6 weeks) healing periods . Results: Porous implants were obtained successfully by powder technology with 52% porosity and pore size 210um 17±. The porous implant showed significantly higher removal torque values when compared to smooth implants at the two different intervals of examination (2,6 weeks) , this proved to be statistically highly significant, also a highly significant difference was noticed for the means of the torque removal values in the same group at different implantation , with no evidence of clinical features of inflammatory reaction with both . Conclusions: Powder technology seemed to be particularly advantageous in fabrication of porous titanium. Porous implant show an increasing bone ingrowth compared with the smooth type represented by higher removal torque for both healing periods (2, 6) weeks . Key words: Porous titanium implant, powder technology, removal torque test.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jan 01 2009
Journal Name
مجلة ديالى للبحوث الانسانية
Synthesis and study of new Macrocyclic ligand type N2O2 and its complexes with (Co (II) ,Ni (II) ,Cu (II) ,Zn (II) and Cd (II)) ions.
...Show More Authors

A new Schiff base ligand [L] [3-methyl-9,10 phenyl -6,7 dihydro-5,8 –dioxo-1,2 diazo –cyclo dodecu 2,11-diene ,4-one ] and its complexes with (Co(II), Ni(II), Cu (II), Zn(II) and Cd(II)) were synthesis.This ligand was prepared in three steps, in the first step a solution of salicyladehyed in methanol reacted under refluxed with hydrazine monohydrate to give an (intermediate compound 1) which reacted in the second step with sodium pyruvate to give an (intermediate compound 2) which gave the ligand [L] in the three step when it reacted with 1,2- dichloro ethane.The complexes were synthesized by direct reaction of the corresponding metal chloride with the ligand. The ligand and complexes were characterized by spectroscopic methods [IR, UV-

... Show More
Publication Date
Thu Oct 01 2020
Journal Name
Biochemical And Cellular Archives
Study on the effect of methotraxate drug on Retinol-Binding Protein 4 (RBP4), nesfatin and some trace elements in Iraqi male patients with rheumatoid arthritis
...Show More Authors

Methotrexate (MTX) is one of the most effective medications to treat rheumatoid arthritis (RA).Aserum of 60 Iraqi male patients suffering from RA as (G1) was newly diagnosis and the same patient in G1 after taking MTX as G2 and 40 Iraqi male healthy control as G3. Nesfatin-1 (Nf-1) is belong to the adipokine family withpleiotropic effect. Nf-1 has been found in different tissues, including stomach, pancreas, bone cells, cartilage and heart. Retinol binding protein (RBP4) was known as transpoter of retinol from its storage sites in the liver to the extrahepatic tissues. Moreover, RBP4 acts as adipokine and contributes in the pathophsyology of prototypic inflammatory disease, rheumatoid arthritis (RA). The results showed a significant increas

... Show More
Scopus
Publication Date
Mon Dec 30 2024
Journal Name
Iraqi Journal Of Science
Synthesis, Characterization, Thermal Studies, and Antioxidant Activities of Azo Dye[2-[(3-Hydroxyphenyl)diazinyl]-1,2-Benzothiazol-3(2H)-one-1,1-Dioxide]and Metal Ion Complexes
...Show More Authors

The new azo dye was synthesized via the reaction of the diazonium salt form of 3-aminophenol with 2-hydroxyquinoline. This dye was then used to access a series of complexes with the chlorides of manganese, iron, zinc, cadmium, and vanadium sulfate. The prepared ligand and its complexes were characterized by FT-IR spectroscopy, UV-visible spectroscopy, mass spectrometry, thermogravimetric analysis, differential scanning calorimeter, and microelemental analysis. Conductivity, magnetic susceptibility, metal content, and chlorine content of the complexes were also measured. The ligand and cadmium complex were identified using1H NMR and 13C NMR spectroscopy. The results showed that the shape of the ligand is a trigonal planner, and the c

... Show More
View Publication
Scopus (7)
Scopus Crossref
Publication Date
Wed Mar 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Effect of Heterogeneity on Capillary Pressure and Relative Permeability Curves in Carbonate Reservoirs. A Case Study for Mishrif Formation in West Qurna/1 Oilfield, Iraq
...Show More Authors

The special core analysis tests were accomplished on a set of core plugs for Mishrif Formation (mA, mB1, and mB2cde/mC units) in West Qurna/1 oilfield, southern Iraq. Oil relative permeability (Kro) data and the Corey-type fit of the data as functions of the brine saturation at the core outlet face for individual samples in the water-oil imbibition process to estimate relative permeability measurements by the centrifuge method were utilized. Identical correlations for oil and water relative permeabilities were extracted by steady-state and unsteady-state methods. For the mA samples, the gas-water capillary pressure curves were within a narrow range (almost identical) indicating that mA is a homogeneous unit. Kro curves for thr

... Show More
View Publication Preview PDF
Crossref (8)
Crossref
Publication Date
Wed Mar 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Effect of Heterogeneity on Capillary Pressure and Relative Permeability Curves in Carbonate Reservoirs. A Case Study for Mishrif Formation in West Qurna/1 Oilfield, Iraq
...Show More Authors

The special core analysis tests were accomplished on a set of core plugs for Mishrif Formation (mA, mB1, and mB2cde/mC units) in West Qurna/1 oilfield, southern Iraq. Oil relative permeability (Kro) data and the Corey-type fit of the data as functions of the brine saturation at the core outlet face for individual samples in the water-oil imbibition process to estimate relative permeability measurements by the centrifuge method were utilized. Identical correlations for oil and water relative permeabilities were extracted by steady-state and unsteady-state methods. For the mA samples, the gas-water capillary pressure curves were within a narrow range (almost identical) indicating that mA is a homogeneous unit. Kro curves for three mB2

... Show More
Crossref (8)
Crossref
Publication Date
Sun Dec 30 2018
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal Of Dissolved Cadmium Ions from Contaminated Wastewater using Raw Scrap Zero-Valent Iron And Zero Valent Aluminum as Locally Available and Inexpensive Sorbent Wastes
...Show More Authors

The current study was to examine the reliability and effectiveness of using most abundant, inexpensive waste in the form of scrap raw zero valent aluminum ZVAI and zero valent iron ZVI for the capture, retard, and removal of one of the most serious and hazardous heavy metals cadmium dissolved in water. Batch tests were conducted to examine contact time (0-250) min, sorbent dose (0.25-1 g ZVAI/100 mL and 2-8 g ZVI/100 mL), initial pH (3-6), pollutant concentration of 50mg/L initially, and speed of agitation (0-250) rpm . Maximum contaminant removal efficiency corresponding to (90 %) for cadmium at 250 min contact time, 1g ZVAI/ 6g ZVI sorbent mass ratio, pH 5.5, pollutant concentration of 50 mg/L initially, and 250 rpm agitation speed wer

... Show More
View Publication Preview PDF
Crossref (12)
Crossref
Publication Date
Fri Jul 01 2022
Journal Name
Sustainable Materials And Technologies
Green approach for fabrication of graphene from polyethylene terephthalate (PET) bottle waste as reactive material for dyes removal from aqueous solution: Batch and continuous study
...Show More Authors

Scopus (38)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Thu Jan 06 2022
Journal Name
Chemical Papers
A solvent collection technique using dispersive liquid–liquid microextraction coupled with spectrophotometry for the trace determination of folic acid in pure, dosage forms and flaxseed
...Show More Authors

A simple, rapid and environmentally friendly dispersive liquid–liquid microextraction method-based spectrophotometric method for the trace determination of folic acid has been developed. The proposed method is based on the formation of a deep yellow product via reaction of folic acid and 1,2-naphthoquine-4-sulfonate at pH = 9. The formed complex was extracted using a mixture of chloroform and ethanol. Then, the tiny organic droplets were measured at λ = 520 nm. At the optimum conditions, linearity was ranged from 0.05 to 1.5 μg/mL for the standard and samples, with a linear correlation coefficient of 0.9996. The detection limits were 0.02, 0.027, 0.03, 0.02 and 0.04 μg/mL for standard, tablet (5 mg), tablet (1 mg), syrup and fl

... Show More
View Publication
Scopus (5)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu Jul 24 2025
Journal Name
Desalination And Water Treatment
Removal of lead, cadmium, and copper from wastewater using Cinnamon bark waste to introduce it as a value-added product: Removal, kinetics and thermodynamics study
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Jun 01 2019
Journal Name
Acta Chromatographica
A simple stability-indicating HPLC method for simultaneous analysis of paracetamol and caffeine and its application to determinations in fixed-dose combination tablet dosage form
...Show More Authors

A simple, economic, rapid, reliable, and stability-indicating high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of paracetamol (PCM) and caffeine (CF) in solid dosage form. The chromatographic separations were achieved with a Waters Symmetry® C18 column (5 μm, 4.6 × 150 mm), using a mixture of methanol and water (40:60, v/v) as a mobile phase, under isocratic elution mode with a flow rate of 0.8 mL/min, and ultraviolet (UV) detection was set at 264 nm. The oven temperature for the column was set and maintained at 35 °C. The method was validated according to International Conference on Harmonization (ICH) guidelines, and it demonstrated excellent linearity, wi

... Show More
View Publication
Scopus (25)
Crossref (21)
Scopus Clarivate Crossref