Background: This study aimed to assess the effect of tooth width in malocclusion in relation to normal, crowding, and spacing dentition. Materials and methods: The sample included dental casts of some dental students and orthodontic patients; their age was (18-25) years and having three groups normal, crowding, and spacing dentition groups. The sample was equally divided to three groups normal, crowding, and spacing dentition groups, each group contained 50 maxillary and 50 mandibular casts that were further subdivided by gender; all the stone casts were measured by highly sensitive digital vernier. Results and Conclusions: Non-significant side difference was found in both dental arches in the three studied groups. Males had higher mesiodistal crown dimension than females in all three groups, with significant gender difference in crowding and normal dentition groups. The mesiodistal distance of the segment measurements (Total Anterior material; Total Posterior material and Total teeth material) were larger in crowded dentition then followed by normal and spaced dentition groups respectively in both gender. Total Anterior material in both arches had direct significant correlation with crowding malocclusion, while maxillary Total Anterior material had indirect significant correlation with spacing malocclusion.
Objective: To assess the nutritional status of hemodialysis patients.
Methodology: A descriptive quantitative cross sectional study was effectuated in hemodialysis centers from
February 2011 to September 2011. A purposive "non-probability" sample of (70) male and female hemodialysis
patients in al-Najaf al-Ashraf Governorate from those who have spent more than six months on maintenance
hemodialysis schedule. Data collected through using of a well-designed questionnaire consist of five parts, part
one consists of sociodemographic contain (9) items, and part two consists of medical data contain (8) items, and
part three consists of health and nutrition behavior contain (12) items plus (8) items of anthropometric
measur
Background: Patients requiring renal biopsies have various glomerular diseases according to their demographic characteristics.
Objective: To study types of glomerular disease among adult Iraqi patients in a single center in Baghdad/Iraq
Material and Methods: A total of 120 native kidney biopsies were studied. All biopsies were adequate and were processed for Light Microscopy.
The age range of the study patients was 17-67 years, with a mean of 38.5 years. The mean follow up period was 28 weeks (4-52 weeks)
Indication for biopsy included: Nephrotic syndrome (N=72; 60%), Asymptomatic proteinuria (N=21; 17.5%), acute nephritic presentation (N=17; 14.16%), asymptomatic haematuria (N=10; 8.33%).
Results: Primary glomerulonephrit
Clavicle fractures are common injuries in young, active individuals. The majority of the fractures (80% to 85%) occur in the mid-shaft of the bone and account for approximately 2.6% of all fractures. For many years the standard treatment of fracture clavicle was the "figure-of-eight" bandage but several indications for operative fixation, the position of plate fixation for clavicle fracture remains controversial. The aim of this study is to compare between anterio—inferior and anterior-superior plating of mid-shaft displaced clavicle fracture in complications, plate prominence, nonunion, malunion and range of motion. This study is a prospective study conducted in Al-Kindy teaching hospital .A total of 30 patients with fracture mid –sh
... Show MoreLinear motor offers several features in many applications that require linear motion. Nevertheless, the presence of cogging force can deteriorate the thrust of a permanent magnet linear motor. Using several methodologies, a design of synchronous single sided linear iron-core motor was proposed. According to exact formulas with surface-mounted magnets and concentrated winding specification, which are relying on geometrical parameters. Two-dimensional performance analysis of the designed model and its multi-objective optimization were accomplished as a method to reduce the motor cogging force using MAXWELL ANSYS. The optimum model design results showed that the maximum force ripple was approximatrly reduced by 81.24%compared to the origina
... Show MoreBackground: The Apgar score is calculated based on the five features: heart rate, reflexes, color, muscle tone, and respiratory effort. Each element is scored from 0 to 2, with a total probable score of 10 at 1 minute and 5 minute. Aim: To study the influence of gestational diabetes mellitus (GDM) and diabetes mellitus on APGAR score in neonate. Materials and methods: The samples were studied from Department of Obstetrics and Gynaecology in Al-Imamain Al-Kadhimiyain (AS) Medical city, Baghdad Teaching Hospital and Al-Karkh Maternity Hospital in the period between 1 December 2016 and 1 may 2017, after obtaining the approval from Iraqi Ministry of Health. A total of 102 neonates were included in this study which includes 34 neonates of mother
... Show MoreThe Journal of Studies and Researches of Sport Education (JSRSE)
The main objective of this work was to adopt an environmentally friendly technology with enhanced results. The technology of magnetic water (MW) treatment system can be used in concrete mixture production instead of potable water (PW) to improve both workability and strength. Two types of concrete were adopted: normal concreter production with two grades 25 and 35 MPa and the self-compacted concrete (SCC) with 35 MPa grade. The concrete mixes containing MW instead of PW results showed that, for 25 MPa grade, an improvement in a compressive strength of 15.1, 14.8, and 10.2% was achieved for 7, 28, and 90 days, respectively. For 35 MPa grade, an improvement of 13.6, 11.5, and
The main objective of this work was to adopt an environmentally friendly technology with enhanced results. The technology of magnetic water (MW) treatment system can be used in concrete mixture production instead of potable water (PW) to improve both workability and strength. Two types of concrete were adopted: normal concreter production with two grades 25 and 35 MPa and the self-compacted concrete (SCC) with 35 MPa grade. The concrete mixes containing MW instead of PW results showed that, for 25 MPa grade, an improvement in a compressive strength of 15.1, 14.8, and 10.2% was achieved for 7, 28, and 90 days, respectively. For 35 MPa grade, an improvement of 13.6, 11.5, and