Background: The development of orthodontic biomaterials that attract less biofilm has been a goal for decades. Adhesion and colonization of cariogenic streptococci are considered to play key roles in the development of enamel demineralization related to orthodontic materials. The aim of this study was to quantitatively evaluate the Mutans streptococci adhesion to coated orthodontic archwires (Epoxy and Teflon) and uncoated archwires (stainless steel and nickel-titanium) with respect to incubation time in the presence and absence of saliva. Material and Method: Six types of archwires stainless steel and nickel titanium with two type of coating (Epoxy, Teflon) were used in this study. Twelve specimens of each archwire were incubated in sterilized unstimulated whole saliva (for the study group) and phosphate-buffered saline (for control group) for 2 hours, then incubated with suspension of Mutans streptococci allowed to adhere for (5,90,180 minutes). Adhesion was quantitated by a microbial culture technique by treating the archwires with adhering bacteria with trypsin and enumerating the colony forming unit (CFU) counts of bacteria recovered after cultivation by using Dentocult SM kit. Results: There was significant difference among the tested archwire types in each time interval with the highest bacterial adhesion on the NiTi archwires in the absence of saliva. In the presence of saliva, the results revealed non-significant difference at 5 min. while there was significant difference at 90 min and highly significant difference at 180 min. Conclusion: The adherence of Mutans streptococci was decreased in the presence of saliva on different archwires and the extended incubation time was significantly related to increase colony forming unit of Mutans Streptococci.
This study aims to develop a thermosensitive mucoadhesive periodontal in situ gel of secnidazole for local release of drug for treatment of periodontitis, in order to increase the drug residence time and to increase patient compliance while lowering the side effects of the drug.
Cold method was used to prepare 30 formulas of secnidazole periodontal in situ gel, using different concentrations of thermosensitive polymers (poloxamer407 alone or in combination with poloxamer 188) and methyl cellulose (MC ) or hydroxypropyl methylcellulose (HPMC K4M )in different concentrations used as mucoadhesive polymer and the resultant formulations were subjected to several tests such as gelation temperature GT, appearance and pH value. The fo
... Show MoreBackground: This study compared in vitro the marginal adaptation of three different, low shrink, direct posterior composites Filtekâ„¢ P60 (packable composite), Filtekâ„¢ P90 (Silorane-based composite) and Sonic fillâ„¢ (nanohybrid composite) at three different composite/enamel interface regions (occlusal, proximal and gingival regions) of a standardized Class II MO cavity after thermal changes and mechanical load cycling by scanning electron microscopy. Materials and methods:Thirty six sound human maxillary first premolars of approximately comparable sizes were divided into three main groups of (12 teeth) in each according to the type of restorative material that was used: group (A) the teeth were restored with Filtekâ„¢ P6
... Show MoreObjective(s): To assess mothers’ knowledge about their children with sickle cell anemia and non-Pharmacological approaches to pain management and found some relationship between mothers knowledge and their demographic data of age, level of education, and occupation.
Methodology: A descriptive design used in the present study established was for a period from September 19th, 2020 to March 30th, 2021. The study was conducted on a non-probability (purposive) sample of (30) mother their children with sickle cell anemia was chosen. The data were analyzed through the application of descriptive and inferential statistical approaches which are applied by using SPSS version 22.0.
Results: The findings of the study indicated that moderate
ABSTRACT Background: Cortical bone thickness is important for the stability of mini implants. Placing mini implants in sites of favorable cortical bone thickness would guarantee better initial stability and long-term success. The aim of this study was to investigate gender, side and jaw differences of the buccal cortical bone thickness as a guide for orthodontic mini screw placement. Materials and Methods: The sample was selected from the patients attending the Specialized Health Center in Al-Sadr City / 3D department. Thirty patients (15 males and 15 females) were selected and cone beam computerized tomographic images were done. Then the buccal cortical bone thickness was measured at thirteen inter radicular sites in the maxilla and mandib
... Show MoreThis study was conducted in the Tissue Culture laboratory of the Horticultural Department of the Faculty of Agriculture at Karbala University to investigate the effects of a light source (Florescent, LED) and adenine sulfate (Ads) a 0, 40, 80, and 120 mg l-1 on the multiplication and rooting of
Background: Studying and investigating the transverse strength(Ts), impact strength(Is), hardness (Hr) and surface roughness(Ra) of conventional and modified autopolymerizing acrylic resin with different weight percentages of biopolymer kraftlignin, after curing in different water temperatures; 40°C and 80°C. Material and Methods: Standard acrylic specimens were fabricated according to ADA specification No.12 for transverse strength, ISO 179 was used for impact testing, Shore D for hardness and profilometerfor surface roughness. The material lignin first dispersed in the monomer, then the powder PMMA is immediately added. Ligninadded in different weight percentages. Then cured using pressure pot (Ivomet) in two temperatures;40°C a
... Show MoreABSTRACT Background: Color changes that are detectable to human eye can affect the esthetic appearance of ceramic veneers. The purpose of this study was to evaluate and compare the effect of artificial accelerated aging on the color of ceramic veneers cemented with different resin cements. Materials and Methods: Sixty discs were prepared with 0.5 mm thickness, 30 discs made from IPS e.max press (Ivoclar Vivadent) and 30 discs were made from VITA Enamic (VITA Zahnfabrik). The discs were cemented with three resin cements: Variolink Veneer MV 0 shade (Ivoclar Vivadent), Rely X veneer Translucent shade (3M ESPE) and NX3 Nexus Clear shade (Kerr Corporation) with 0.1 mm thickness. The spectrophotometer Easyshade Advance was used to measure the co
... Show MoreBackground: Peripheral giant cell lesion (PGCL) and central giant cell lesion (CGCL) of the jaws have a distinct clinical behavior.Giant cell tumour (GCT) is a benign locally aggressive neoplasm affects the long bones. Both lesions are characterized histologically by multinucleated giant cells in a background of ovoid to spindle-shaped mesenchymal cells. The WW domain-containing oxidoreductase (WWOX) gene is located at 16q23.1–16q23.2, a region that spans the second most common human fragile site, FRA16D, at 16q23.2.The Ki-67 antigen is a nuclear protein that is associated with and may be necessary for cellular proliferation.Ki-67 protein is present during all active phases of the cell cycle (G1, S, G2, and mitosis), but is absent fr
... Show MoreBackground and objectives: This study aimed at testing the effect of plastic sleeve or barrier, used to cover the guide of the light cure unit to prevent cross-infection, on the shear bond strength and site of bond failure of stainless steel and ceramic orthodontic brackets. Materials and methods: Forty orthodontic brackets; twenty stainless steel and twenty ceramic brackets bonded to forty extracted human maxillary first premolars using light cure adhesive cured with and without the use of a protective plastic barrier on the guide. Comparing the effect of this barrier on the shear bond strength and adhesive remnant index was performed using an independent t-test and Chi-square test. Results: The protective barrier had decreased the shear b
... Show More