Background: The development of orthodontic biomaterials that attract less biofilm has been a goal for decades. Adhesion and colonization of cariogenic streptococci are considered to play key roles in the development of enamel demineralization related to orthodontic materials. The aim of this study was to quantitatively evaluate the Mutans streptococci adhesion to coated orthodontic archwires (Epoxy and Teflon) and uncoated archwires (stainless steel and nickel-titanium) with respect to incubation time in the presence and absence of saliva. Material and Method: Six types of archwires stainless steel and nickel titanium with two type of coating (Epoxy, Teflon) were used in this study. Twelve specimens of each archwire were incubated in sterilized unstimulated whole saliva (for the study group) and phosphate-buffered saline (for control group) for 2 hours, then incubated with suspension of Mutans streptococci allowed to adhere for (5,90,180 minutes). Adhesion was quantitated by a microbial culture technique by treating the archwires with adhering bacteria with trypsin and enumerating the colony forming unit (CFU) counts of bacteria recovered after cultivation by using Dentocult SM kit. Results: There was significant difference among the tested archwire types in each time interval with the highest bacterial adhesion on the NiTi archwires in the absence of saliva. In the presence of saliva, the results revealed non-significant difference at 5 min. while there was significant difference at 90 min and highly significant difference at 180 min. Conclusion: The adherence of Mutans streptococci was decreased in the presence of saliva on different archwires and the extended incubation time was significantly related to increase colony forming unit of Mutans Streptococci.
The paper present design of a control structure that enables integration of a Kinematic neural controller for trajectory tracking of a nonholonomic differential two wheeled mobile robot, then proposes a Kinematic neural controller to direct a National Instrument mobile robot (NI Mobile Robot). The controller is to make the actual velocity of the wheeled mobile robot close the required velocity by guarantees that the trajectory tracking mean squire error converges at minimum tracking error. The proposed tracking control system consists of two layers; The first layer is a multi-layer perceptron neural network system that controls the mobile robot to track the required path , The second layer is an optimization layer ,which is impleme
... Show MorePreparation of identical independent photons is the core of many quantum applications such as entanglement swapping and entangling process. In this work, Hong-Ou-Mandel experiment was performed to evaluate the degree of indistinguishability between independent photons generated from two independent weak coherent sources working at 640 nm. The visibility was 46%, close to the theoretical limit of 50%. The implemented setup can be adopted in quantum key distribution experiments carried out with free space as the channel link, as all the devices and components used are operative in the visible range of the electromagnetic spectrum.
The efficacy of five insect growth regulators has been tested against white fly larva Alearoclava jasimini on citrus tree orchards. Data from field tl'ia ls con finned that percent mortalities were 43.7, 33.9, 23.7, 20.8 and 12.3 for Admiral ( I miL) pyriproxefen, Nomol t 1 5 SC (!milL) Teflubenzuren , Match 050 EC ( I milL ) Lufenuren , cascade I 0 F.C (
0.9mi/L) flufenoxaron, and Dimiline 10 EC ( I milL) Difluben- zuron. The result indicated that Admiral and Nomolt have a continuous effect for one month , so the treatment needs to be repeated for each four weeks. Also, Admiral and Nomolt effect against eggs hatching by 41. 3 % and
The ABO blood group system is highly polymorphic, with more than 20 distinct sub-groups; study findings are usually related to ABO phenotype, but rarely to the ABO genotype and animal models are unsatisfactory because their antigen glycosylation structure is different from humans. Both the ABO and Rh blood group systems have been associated with a number of diseases, but this is more likely related to the presence or absence of these tissue antigens throughout the body and not directly or primarily related to their presence on RBCs. A total of fifty-two 52 patients without complication of DMII, two hundred sixteen 216 patients with complication of DMII and seventy-one 71 person as healthy control were included in the study. The resu
... Show MoreThe variety of ideas and freedom of expression among the authors who are looking for everything new that serves the goals of musical and aesthetic expression, which calls for the use of traditional musical instruments with the great composition of musical instruments known as the orchestra represents a great challenge in several aspects. The incompetence of some of these instruments or limited capabilities or its costly method of performance sometimes forbids its use permanently in this great composition. It was necessary to have some problems facing the composer and the player on the one hand and the recipient on the other hand, who must be looking for perfection. Among those instruments that are used regularly in the works of the orche
... Show MoreThis study discussed a biased estimator of the Negative Binomial Regression model known as (Liu Estimator), This estimate was used to reduce variance and overcome the problem Multicollinearity between explanatory variables, Some estimates were used such as Ridge Regression and Maximum Likelihood Estimators, This research aims at the theoretical comparisons between the new estimator (Liu Estimator) and the estimators
Real Time Extended (RTX) technology works to take advantage of real-time data comes from the global network of tracking stations together with inventor locating and compression algorithms to calculate and relaying the orbit of satellite, satellite atomic clock, and any other systems corrections to the receivers, which lead to real-time correction with high accuracy. These corrections will be transferred to the receiver antenna by satellite (where coverage is available) and by IP (Internet Protocol) for the rest of world to provide the accurate location on the screen of smartphone or tablet by using specific software. The purpose of this study was to assess the accuracy of Global Navig