Background: The Initial (primary) stability is one of the factors that play an important role in the success of the dental implants. The purpose of this study was to evaluate the initial stability of dental implant with horizontal plate by using five analytical tests: insertion torque, removal torque, resonance frequency analysis, push-in test and pull-out test. Materials and methods: Two different lengths of dental implants (5mm and 10mm) were tested in this study; each dental implant was 4mm in diameter with a square threads shape of 1mm pitch and 0.5mm depth. The crestal area was 4.2mm diameter contained a right angle margin circumferential ring while the apical area was tapered with two self-tapping grooves. In this study, the initial stability of dental implants’ design was compared with initial stability of dental implants of the same dimensions and design that engage horizontal plates of 1.5mm thickness at the apical part. All dental implants were implanted into a solid rigid polyurethane foam blocks (artificial bone) of 0.48g/cm3 density and tested by the five initial stability tests. Each test was done with forty samples (twenty samples of 5mm length and twenty samples of 10mm length). Results: The statistical analysis was performed and the result showed that there was very highly significant difference between dental implants with the horizontal plates and dental implants without the horizontal plates of both 5mm and 10 mm lengths in four initial stability tests which were insertion torque, removal torque, push-in test and pull-out test. The statistical analysis of the resonance frequency analysis showed that there was non-significant difference between dental implants with the horizontal plates and dental implants without the horizontal plates of both lengths. Conclusion: These results implied that the dental implants with the horizontal plates had better primary stability compared with the dental implants without the horizontal plates confirming that the horizontal plates enhanced the primary stability of the dental implants.
The present study discusses the names of the Day of Resurrection in Uri Rubin’s translations of the Holy Qur’an. To identify the translation difficulties and complications and to find out the Hebrew equivalence, the study, through the application of a comparative analytical approach, aims at analyzing the linguistic structures of Day of Resurrection names cited in the Holy Qur’an. Heavenly religions are rich with distinct and unique terms that distinguish and reflect their specificity of other religions; something requires a great accuracy in the translation of such terminology. By investigating selected examples of the names of the Day of Resurrection in Arabic and Hebrew, the present study sheds light on the morphological and semant
... Show MoreAbstract
This Study aimed to investigate the reality of the application of the degree of management practice by Walking Around, namely (discovery of facts, improvement of communication, motivation, development, creativity and feedback) and Its role in achieving organizational justice (procedural justice, distributive justice, Interactional Justice),The availability of the core principles of this system from the point of view of the senior management personnel in the Directorate of Anbar Education, and the importance of research in the philosophical rooting of the nature of the variables as a modern administrative terminology, the research dealt with a problem expressed by a number of intellectual and appl
... Show MoreIn this paper, a discrete SIS epidemic model with immigrant and treatment effects is proposed. Stability analysis of the endemic equilibria and disease-free is presented. Numerical simulations are conformed the theoretical results, and it is illustrated how the immigrants, as well as treatment effects, change current model behavior
BN RASHİD, 2023
The deficiency in the nurse staff in the health organizations consider an important problem that must be studied and solved basically , not only because it affect on the health organization and it's strategic goals , but also it affect the human being and it's health which can't be substituted with anything or delayed in it's treatment ,This research aims to necessary for health organizations to strategically help in maintaining the nurse staff and to keep that in it's strategic orientation and it's mission , moreover , the health organizations must study the reality of the nurse in the health organizations and know the causes beyond leaving the nurse staff the nurse job , and then remove
... Show Moregenerator the metal conductor is replaced by conducting gas plasma.
Background: Information concerning the maximum bite force in human population is important to clinical orthodontics. Additionally, the influence of bite force on the vertical stability of any treatment result is important. The new position of the dentition should be compatible with the dynamics of the muscular and occlusal forces in all planes. This study was conducted to 1) to measure and compare maximum bite force, body height and weight among normal occlusion and malocclusion groups (cl I,cl II,cl III) in both gender 2) to evaluate the correlation between bite force and craniofacial morphology, body height and weight. Materials and Methods: The sample consists of 100 Iraqi adult subjects aged 18-25 years. It was classified in to four gr
... Show More
This research aims to apply the Performance Focused Activity Based Costing System in the offices of scientific and advisory services at the University of Technology for the purpose of measuring the cost of services provided by these offices in order to reduce costs. To test the hypothesis of the research, the research was applied in the consulting offices of the University of Technology through the financial statements for the year ending 12/31/2017 of the Scientific and Consulting Services Office of the University of Technology, because the data of these years were issued and audited by the Federal Office of Financial Supervision.
A number of
... Show More