Background: The Initial (primary) stability is one of the factors that play an important role in the success of the dental implants. The purpose of this study was to evaluate the initial stability of dental implant with horizontal plate by using five analytical tests: insertion torque, removal torque, resonance frequency analysis, push-in test and pull-out test. Materials and methods: Two different lengths of dental implants (5mm and 10mm) were tested in this study; each dental implant was 4mm in diameter with a square threads shape of 1mm pitch and 0.5mm depth. The crestal area was 4.2mm diameter contained a right angle margin circumferential ring while the apical area was tapered with two self-tapping grooves. In this study, the initial stability of dental implants’ design was compared with initial stability of dental implants of the same dimensions and design that engage horizontal plates of 1.5mm thickness at the apical part. All dental implants were implanted into a solid rigid polyurethane foam blocks (artificial bone) of 0.48g/cm3 density and tested by the five initial stability tests. Each test was done with forty samples (twenty samples of 5mm length and twenty samples of 10mm length). Results: The statistical analysis was performed and the result showed that there was very highly significant difference between dental implants with the horizontal plates and dental implants without the horizontal plates of both 5mm and 10 mm lengths in four initial stability tests which were insertion torque, removal torque, push-in test and pull-out test. The statistical analysis of the resonance frequency analysis showed that there was non-significant difference between dental implants with the horizontal plates and dental implants without the horizontal plates of both lengths. Conclusion: These results implied that the dental implants with the horizontal plates had better primary stability compared with the dental implants without the horizontal plates confirming that the horizontal plates enhanced the primary stability of the dental implants.
This study aimed to improve the microencapsulation technique using a type coating the encapsulation Layer by Layer, which provide the best protection for life Lactobacillus casei in the extrusion method and use the microencapsulation of materials of the protein concentrated by protein 80% and the coating with alginate and chitosan have the results showed the variation in the difference of the binding process encapsulation yield among the types of coating through. by studying of these the effect o stability of the bio probiotic free cell and the three types coated towards three different concentrations from bile salts 0, 0.3, 0.5 and 0.7% when the periods of time different of zero and two and three hours at incubation the recorded
... Show MoreApical meristems, lateral buds, anthers of immature flowers and immature embryos of chickpea ( Cicer arietinum L.) were cultured on MS media with different growth regulators and incubated for 6 weeks at 25-27?C with 16 hrs photoperiod for callus initiation. Results indicated that 1 and 0.1 mg/l of 2,4-D and BA were suitable for callus initiation when apical meristems and lateral buds were used. While 2 and 0.5 mg/l of both growth regulators were essential for immature embryos. It was noticed that using chickpea anthers of the MS medium must contain 1mg/l 2ip and 0.5 mg/l IAA. However, MS medium supplemented with 1-3 mg/l of BA and 2,4-D respectively was good for callus initiation from lateral buds, anther and immature embryos.
... Show MoreBackground: The fracture of instruments within root canal during endodontic treatment is a common incidence, fracture because of fatigue through flexure occurs due to metal fatigue, this study aimed to assess the effect of curvature angle and rotational speed on the cyclic fatigue of different type of Endodontic NiTi Rotary Instruments and compare among them. Materials and method: Three types of rotary instruments with tip size 0.25: ProTaPer F2 (Densply, Malifier) Revo-S SU( 0.06 taper, MicroMega) and RaCe system (0.06 taper, FKG, Dentaire), Forty file of each instrument were used within two canals with angle of curvature (40 &60 )at two speed (250&400)RPM, twelve group were formed for all instruments(total number=120),ten file fo
... Show MoreBackground: A case-control study design revealeda relationship between the present of fluoride, and the reduction of dental caries and the increase prevalence and severity of dental fluorosis .The aim of this study was to assess the prevalence and severity of dental caries in relation to dental fluorosis among school children in Al-Muthana'a Governorate. Materials and methods: It was conducted among primary school students aged 12 years old, the age was taken according to the criteria of World Health Organization (1997) (1).The number of students was selected in each sector of control group according to number of schools in that sector .Sectors of control group which depend on water of river as source of drinking water. Case group which inc
... Show MoreVisceral leishmaniosis is one of the most fatal old-world neglected disease with estimated 90 thousand worldwide cases emerge each year. In Iraq, the cutaneous and visceral form are endemic but available chemotherapies are either toxic with diverse side effects, expensive available drugs or parasite …
In this paper, compared eight methods for generating the initial value and the impact of these methods to estimate the parameter of a autoregressive model, as was the use of three of the most popular methods to estimate the model and the most commonly used by researchers MLL method, Barg method and the least squares method and that using the method of simulation model first order autoregressive through the design of a number of simulation experiments and the different sizes of the samples.
The main objective of this study is to determine whether the use of He-Ne Laser (632.8 nm wavelength and power 0.5 mW) is an eligible and effective tool to kill or reduce the cell viability of Candida albicans isolated from complete upper dentures. Twenty one swabs were taken from the complete upper dentures. Only six swabs showed positive cultures for C. albicans. The isolate was divided into two groups, group I was not irradiated (control), and group II was irradiated by He-Ne Laser for different periods (10, 15, 20, and 30) min. After irradiation, the results showed a significant reduction in the viable cell count and colonies diameters especially at exposure periods 10 and 15 min. Although the low power He-Ne Laser was not eradicating t
... Show MoreIn the present study a new synthesis method has been introduced for the decoration of platinum(Pt) on the functionalized graphene nanoplatelet (GNP) and also highlighted the preparation method of nanofluids. GNP–Pt uniform nanocomposite was produced from a simple chemical reaction procedure, which included acid treatment for functionalization of GNP. The surface characterization was performed by various techniques such as XRD, FESEMand TEM. The effective thermal conductivity, density, viscosity, specific heat capacity and stability of functionalized GNP–Pt water based nanofluids were investigated in different instruments. The GNP–Pt hybrid nanofluids were prepared by dispersing the nanocomposite in base fluid without adding any surfac
... Show MoreIn this paper the concept of (m, n)- fully stable Banach Algebra-module relative to ideal (F − (m, n) − S − B − A-module relative to ideal) is introducing, we study some properties of F − (m, n) − S − B − A-module relative to ideal and another characterization is given
Background: Vitamin D improves innate immunity by enhancing the expression of antimicrobial peptides. The antimicrobial action of cathelicidin is widespread and effective against cariogenic bacteria. This research aimed to investigate the effect of vitamin D deficiency on the level of salivary cathelicidin concerning dental caries experience.
Subjects and Methods: A case-control study was carried out, and the sample was composed of 80 females; the study group involved 40 females with a serum vitamin D concentration of less than 10 ng/ml. In addition to the control group involving 40 females wh
... Show More