Background: This in vitro study measure and compare the effect of light curing tip distance on the depth of cure by measuring vickers microhardness value on two recently launched bulk fill resin based composites Tetric EvoCeram Bulk Fill and Surefil SDR Flow with 4 mm thickness in comparison to Filtek Z250 Universal Restorative with 2 mm thickness. In addition, measure and compare the bottom to top microhardness ratio with different light curing tip distances. Materials and Method: One hundred fifty composite specimens were obtained from two cylindrical plastic molds the first one for bulk fill composites (Tetric EvoCeram Bulk Fill and Surefil SDR Flow) with 4 mm diameter and 4 mm depth, the second one for Filtek Z250 Universal Restorative with 4 mm diameter and 2 mm depth. Each spcimen was light-cured using WOODPECKER LED CURING LIGHT for 20 sec. Polymerization was performed with the light tip positioned in direct contact, 2 mm, 4 mm, 6 mm and 8 mm distant from the top surface of the sample. After one day of storage in distilled water in a light proof container at 37ËšC, the hardness on the bottom and top surfaces of each specimen was tested using the Digital Micro Vickers Hardness Tester. Then the Data were analyzed statistically by ANOVA test, LSD test and t-test. Results: All experimental groups show top microhardness higher than bottom microhardness with high significant difference with all light tip distances. At 0 mm light tip distance all groups give the highest microhardness value. Filtek Z250 Universal Restorative shows accepted bottom to top microhardness ratio at all light tip distances. Surefil SDR Flow shows accepted bottom to top ratio only at 0, 2 and 4mm light tip distances while Tetric EvoCeram Bulk Fill shows the bottom to top microhardness ratio less than the accepted value with all light tip distances. Conclusion: From the results of this study we can conclude that the polymerization of bulk fill composite depends greatly on the distance from light curing tip, Tetric EvoCeram Bulk Fill composite not recommended to be used as bulk fill restoration in deep cavities and need further studies, while Surefil SDR Flow not recommended to be used in deep cavity when curing tip distance (6-8 mm), in addition we can conclude that the thickness of the increments is more important than light curing tip distance.
Objective(s): In the present study, glycerin is used as a substitute for tin-foil and cold mold seal (Alginate mould seal)
in the process of curing heat and cold-cure acrylic resin denture base against stone and plaster.
Methodology: 60 specimens were prepared from heat-cure acrylic resin and cold-cure acrylic resin denture base. The
study includes 12 groups of specimens depending on the type of processing, investment material and type of
separating medium that are used in curing process. Each group of them contains 5 specimens for each test.
Some of physical properties of the processed acrylic denture base that (water sorption and solubility) have been
compared with those processed using tin-foil and tin-foil substitut
Background: The beneficial gut bacterium E. coli can cause blood poisoning, diarrhoea, and other gastrointestinal and systemic disorders. Objective: This study amid to examines the antibiofilm activity of Laurus nobilis leaves extract on E. coli isolates and compares pre- and post-treatment gene expression of fimA and papC genes. Subjects and Methods: Ten isolates of E. coli were obtained from the Genetic Engineering and Biotechnology Institute, University of Baghdad, which was previously collected from Baghdad city hospitals and diagnosed by chemical tests, the diagnosis was confirmed using VITEK-2 System. The preparation of the aqueous and methanolic Laurus nobilis leaves extracts was done by using the maceration method and Soxhlet appara
... Show MoreObjective: To enhance bonding strength between thermoplastic denture base and acrylic soft liner through ethyl acetate surface treatment. Materials and Methods: Modifications of thermoplastic acrylic denture base surface were investigated with SEM. FTIR was used to detect whether there was a chemical bond between thermoplastic acrylic and the organic solvent. A total of 80 samples were prepared and divided into 20 samples for the surface roughness test and 60 samples for the shear bond strength test. Failure type was assessed visually. Results: Shear bond strength and surface roughness values of un treated samples were lower in comparison to surface treated groups; the greatest post thermocycling bond strength value was recorded for the sam
... Show MoreBreast cancer is one of the most important malignant diseases all over the world. The incidence of breast cancer is increasing around the world and it is still the leading cause of cancer mortality An Approximately 1.3 million new cases were diagnosed worldwide last year. With areas rising increasing, risk factors for breast cancer including obesity, early menarche, alcohol and smoking, environmental contamination and reduced or late birth rates become more prevalent. In Iraq, breast cancer ranks first among types of cancers diagnosed in women. This study was conducted on one hundred twenty women with breast cancer that was evaluated and investigated for the possible role of the risk factors on the development of breast cancer in females. T
... Show MoreThis study aimed to evaluate oral health (OH) and periodontal diseases (PD) awareness in the Iraqi population.
This study was a questionnaire‐based online survey of two weeks duration. The questionnaire was built using a Google platform and was distributed randomly via social media (Facebook and Telegram). The questionnaire consisted of a demographic data section and two other main sections for the evaluation of OH and PD awareness. Each response was marked with “1” for a positive answer and “0” for the other answers. For each respondent, answers were summed to give
Abstract
In this investigation, Al2O3 nano material of 50nm particles size were added to the 6061 Al aluminium alloy by using the stir casting technique to fabricate the nanocomposite of 10wt% Al2O3. The experimental results observed that the addition of 10wt% Al2O3 improved the fatigue life and strength of constant and cumulative fatigue. Comparison between the S-N curves behaviour of metal matrix (AA6061) and the nanocomposite 10wt% Al2O3 has been made. The comparison revealed that 12.8% enhancement in fatigue strength at 107cycles due to 10wt% nano reinforcement. Also cumulative fatigue l
... Show More