Preferred Language
Articles
/
jbcd-590
The effect of light curing tip distance on the curing depth of bulk fill resin based composites
...Show More Authors

Background: This in vitro study measure and compare the effect of light curing tip distance on the depth of cure by measuring vickers microhardness value on two recently launched bulk fill resin based composites Tetric EvoCeram Bulk Fill and Surefil SDR Flow with 4 mm thickness in comparison to Filtek Z250 Universal Restorative with 2 mm thickness. In addition, measure and compare the bottom to top microhardness ratio with different light curing tip distances. Materials and Method: One hundred fifty composite specimens were obtained from two cylindrical plastic molds the first one for bulk fill composites (Tetric EvoCeram Bulk Fill and Surefil SDR Flow) with 4 mm diameter and 4 mm depth, the second one for Filtek Z250 Universal Restorative with 4 mm diameter and 2 mm depth. Each spcimen was light-cured using WOODPECKER LED CURING LIGHT for 20 sec. Polymerization was performed with the light tip positioned in direct contact, 2 mm, 4 mm, 6 mm and 8 mm distant from the top surface of the sample. After one day of storage in distilled water in a light proof container at 37ËšC, the hardness on the bottom and top surfaces of each specimen was tested using the Digital Micro Vickers Hardness Tester. Then the Data were analyzed statistically by ANOVA test, LSD test and t-test. Results: All experimental groups show top microhardness higher than bottom microhardness with high significant difference with all light tip distances. At 0 mm light tip distance all groups give the highest microhardness value. Filtek Z250 Universal Restorative shows accepted bottom to top microhardness ratio at all light tip distances. Surefil SDR Flow shows accepted bottom to top ratio only at 0, 2 and 4mm light tip distances while Tetric EvoCeram Bulk Fill shows the bottom to top microhardness ratio less than the accepted value with all light tip distances. Conclusion: From the results of this study we can conclude that the polymerization of bulk fill composite depends greatly on the distance from light curing tip, Tetric EvoCeram Bulk Fill composite not recommended to be used as bulk fill restoration in deep cavities and need further studies, while Surefil SDR Flow not recommended to be used in deep cavity when curing tip distance (6-8 mm), in addition we can conclude that the thickness of the increments is more important than light curing tip distance.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 07 2021
Journal Name
2021 14th International Conference On Developments In Esystems Engineering (dese)
Content Based Image Retrieval Based on Feature Fusion and Support Vector Machine
...Show More Authors

View Publication
Scopus (10)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Human Sport And Exercise - 2019 - Spring Conferences Of Sports Science
The effect of continuous training on myoglobin muscle and on some specific fitness elements and basic skills of badminton players
...Show More Authors

View Publication Preview PDF
Scopus (11)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Jun 30 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
SYNTHESIS OF NEW LEVOFLOXACIN SELECTIVE MEMBRANE SENSOR BASED ON MOLECULARLY IMPRINTED POLYMERS.: SYNTHESIS OF NEW LEVOFLOXACIN SELECTIVE MEMBRANE SENSOR BASED ON MOLECULARLY IMPRINTED POLYMERS.
...Show More Authors

Two molecular imprinted polymer (MIP) membranes for Levofloxacin (LEV) were prepared based on PVC matrix. The imprinted polymers were prepared by polymerization of styrene (STY) as monomer, N,N methylene di acrylamide as a cross linker ,benzoyl peroxide (BPO) as an initiator and levofloxacin as a template. Di methyl adepate (DMA) and acetophenone (AOPH) were used as plasticizers , the molecular imprinted membranes and the non molecular imprinted membranes were prepared.  The slopes and detection limits of the liquid electrodes ranged from -21.96 – -19.38 mV/decade and 2×10-4M- 4×10-4M, and Its response time was around 1 minute, respectively. The liquid  electrodes were packed with 0.1 M standar

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 30 2025
Journal Name
مجلة القادسية للقانون والعلوم السياسية
Insurance of Unlawful Risks: Towards a Reinterpretation of Public Policy in Light of the Protection of Innocent Victims and Freedom of Contract
...Show More Authors

The issue of insurance against unlawful risks raises a jurisprudential and judicial debate between two opposing trends: the first considers coverage of these risks invalid due to their impact on public order or morals, while the second—which this research analyses—calls for the possibility of covering these risks in specific circumstances, based on contractual considerations in accordance with the principle that the contract is the law of the contracting parties, and based on the obligation to compensate the harmed third party—the victim—who has no connection to the unlawful act. In this context, our research highlights that contractual considerations can justify coverage of some unlawful risks, provided that the goal is to achieve

... Show More
View Publication
Publication Date
Thu Oct 01 2015
Journal Name
Journal Of Educational And Psychological Researches
Anxiety of death among pregnant women in the light of some Demographic variables Governorates Bethlehem and Tulkarm as a model
...Show More Authors

This study aims to identify the anxiety pregnant women have of dying, in the light of some Demographic variables in Bethlehem (age, residence, and the mother's job). The descriptive method was used in this study. To achieve the study purposes, the researchers developed a questionnaire as a tool of study, which consisted of (19) paragraphs ,after been verified of its validity & stability.

The researchers distributed questionnaires, and then analyzed them. Results illustrated that the levels of anxiety pregnant women in Bethlehem had of dying was average,  with a mean total score of (3.11),  and with a standard deviation that had the total score of (0.476). Results also illustrated statistical differences in the pregn

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 28 2020
Journal Name
Journal Of The College Of Education For Women
Academic Boredom in the Light of some Variables of Academically Excellent Intermediate Stage Students: زهراء سعد العبودي , انتصار كمال العاني
...Show More Authors

Academic boredom is one of the most emotional problems that arouse an individual's fatigueness and lowers his interest. This is because of the environment's low efficiency and of spending long monotonous time. This state is characterized by having lack of interest, difficulties in concentration, and the desire to leave the class.  It is considered one of the most prominent forms of boredom widespread among students and the most severe and dangerous one that has negative effects and severe psychological and social problems. The current research aims to investigate a randomly selected sample of 335 students from the first and third grades at the directorates of education (Karkh and Rusafa) who suffers from academic boredom. Similarily

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Feb 15 2025
Journal Name
Iraqi Journal Of Science
Study of Longitudinal Electron Scattering Form Factors with the Radial Wave functions of Transformed Harmonic-Oscillator for some Light Nuclei
...Show More Authors

The wave functions of converted harmonic-oscillator in local scaling transformations are employed to evaluate charge distributions and elastic charge electron scattering form structures for 6,7Li, 9Be, 14,15N and 16O nuclei. The nuclear shell-model was fulfilled using Warburton-Brown  psd-shell (WBP) interaction with  truncation in  model space. Very good agreements with the experimental data were obtained for the aforementioned quantities. 

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
The Effect of Power Sources in the Agricultural Tractor and the Developed Sprayer System on the Performance of the Electrical and Mechanical Sprayer System and some Performance Indicators of the Engine
...Show More Authors
Abstract<p>An experiment was conducted to study the effect of the sprayer type according to the source of power and the size of the spray nozzle concerning the quality of the spray produced and fuel consumption.Two types of sprayers were used: a conventional boom sprayer (S1) and a modified (electrified) boom sprayer (S2), along with three sizes of the XR TeeJet 110 spray nozzle (N). The following technical performance indicators were examined: Density of coverage (drops/cm2) using ImageJ software, a 600dpi business card scanner, specifically the ScanShell 800N by CSSN, Inc, and water-sensitive paper (WSP), rate of spray nozzles discharge (ml/min), and fuel consumption (liters/hectare) using a c</p> ... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Oct 04 2022
Journal Name
Lecture Notes In Mechanical Engineering
Effect of Stator Core Materials on the Performance Characteristics of a Free Piston Linear Generator Engine
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun Jan 18 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of intracrevicular injection of fucose on serum interlukine -1beta and tumor necrosis factor alpha
...Show More Authors

Background: ?-L-Fucose is a methyl pentose sugar, had the ability to kill bacteria, controlling infection and normalize immune function. The objective of this study is to determine the effect of sulcular injection of fucose on rabbits periodontium , throughout measuring the level of some proinflammatory cytokine ; interlukine 1beta ( IL-1beta) and tumor necrosis factor ( TNF-alpha) in sera of rabbits before fucose injection and at 3 days after fucose injection. Materials and Methods: The study was carried on using ( 20 ) male rabbits of the same species weighted (1-1.5 kg ) , the blood samples were collected from hearts of 20 rabbits before fucose injection and consider as( non injected group) , and after 3 days of fucose injection and con

... Show More
View Publication Preview PDF