Preferred Language
Articles
/
jbcd-587
Evaluation of shear bond strength between thermosens as relining material and different denture base materials
...Show More Authors

Background: Denture relining is the process of resurfacing of the tissue side of the ill fitting denture, the bond strength at the relining-denture base interface is most important for denture durability.The aim of present study was to evaluate the shear bond strength between the thermosens as relining material and different denture base materials that bonded by thermo fusing liquid. As this corrective procedureis the common chair side procedure in the dental clinic. Material and method: Sixty samples were prepared and divided into three main groups according to the type of denture base materials.Group (A) referred to the heat cure acrylic samples which consisted of 20 samples. Group (B) referred to the high impact acrylic samples which consisted of 20 samples. Group (C) referred to the thermosens samples which consisted of 20 samples. All groups then subdivided into two groups; each one consists of 10 samples, according to the surface roughness: (A1, B1and C1 for groups with surface roughness and A2, B2 and C2for groups without surface roughness). Each sample consisted of two similar parts represent the denture base material each part of the sample was designed with dimensions of (70mm X 12mm X 5mmlength, width and depth respectively) having a stopper of depth 3mm. One part of the sample was placed on the other in a manner thatleaving a space between them of dimensions (12mm X 12mm X 3mm length, width and depth respectively) to sandwich the relining material. Results: The results showed that the thermosens samples had the highest value of shear bond strength followed by the high impact acrylic samples, then heat cure acrylic samples which had the lowest value of shear bond strength. The results of present study showed that rough samples had reducedshear bondstrength in comparison with the smooth samples of the same denture base material.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jul 01 2012
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Relationship between Neonatal septicemia and birth weight
...Show More Authors

Background: Neonatal Septicemia (NNS) is generalized microbial symptomatic infection during the first 28 days of life.It>s the most serious complication in Neonatal Intensive Care Units (NICU) that demand urgent diagnosis and accurate treatment.Objective: To reveal the relationship of neonatal septicemia with birth weight (one of the neonatal risk factors).Patients and Methods: Blood sample was obtained from 76 neonates aged 1 hour-28 days who were diagnosed clinically (poor feeding, respiratory distress, fever, hypothermia, gastrointestinal and/or central nervous system symptoms)and bacteriologically to have neonatal septicemia.Results:One of the most important neonatal factor predisposing to infection is low birth weight, signi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Nov 06 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Correlation between Thyroid-related Hormones and Preeclampsia
...Show More Authors

Objectives: In order to highlight the TSH and thyroid hormones levels in preeclamptic and healthy pregnant
women.
Methodology: Ninety patients with preeclampsia were divided into two groups according to the severity of
disease; those with mild disease (37 patients) and those with a severe form (53 patients). A separate group of 30
normal women were included as a normal control group. Venus blood samples were collected from all groups
and the serum was obtained for hormone analysis by ELISA test. Results are expressed using SPSS for window
version 11.0.
Results: Mean serum TSH levels were significantly increased in both of mild and severe preeclampsia compared
with normal pregnancy, and T3 serum level showed a sign

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 31 2015
Journal Name
Al-khwarizmi Engineering Journal
Study Tensile Strength and Wear Rate for Unsaturated Polyester Resin and Nitrile butadiene Rubber Polymer Blend
...Show More Authors

Abstract

    Binary polymer blend was prepared by mechanical mixing method of unsaturated polyester resin with Nitrile Butadiene Rubber (NBR) with different weight ratios (0, 5, 10 and 15) % of (NBR). Tensile characteristics and wear rates of these blends were studied for all mixing ratios. The microstructure of fracture surfaces of the prepared samples were investigated by optical microscope. The results were showed that strain rates of the resin material increase after blending it with rubber while the ultimate tensile strength and Young’s modulus values of it will decrease. It is also noticed that the wear rate of resin decreases with increasing of (NBR) content.

Keywords:<

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 01 2021
Journal Name
Journal Of Dental Sciences
Evaluation of the efficacy of lycopene gel compared with minocycline hydrochloride microspheres as an adjunct to nonsurgical periodontal treatment: A randomised clinical trial
...Show More Authors

Scopus (12)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Mon Mar 01 2021
Journal Name
Journal Of Dental Sciences
Evaluation of the efficacy of lycopene gel compared with minocycline hydrochloride microspheres as an adjunct to nonsurgical periodontal treatment: A randomised clinical trial
...Show More Authors

View Publication
Scopus (12)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Thu Jan 31 2019
Journal Name
Journal Of The College Of Education For Women
The Effect of the Portal System in Achievement Motivation and Cognitive of Fifth Grad Students in Geographic Literary Material
...Show More Authors

The study aimed to identify the impact of the use of systemic approach in the collection of geographical material and cognitive motivation when fifth grade students of literary, experimental design researcher adopted a partial seizures, and telemetric to two unequal one experimental and the other officer.
The sample consisted of fifth grade literary students from secondary (inherent) for Boys in Baghdad (the Republic of Iraq. (By Mjootain, and the number of students of each group (30 students). And has rewarded the two groups, in the variables (chronological age, average scores half-year, degree IQ),
Promising researcher himself requirements of research to determine the scientific material and teaching plans and the formulation of

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 01 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Assessing the Radiopacity of Three Resin Composite Materials Using a Digital Radiography Technique
...Show More Authors

Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Assessing The Radiopacity of Three Resin Composite Materials Using a Digital Radiography Technique
...Show More Authors

Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Iraqi Journal Of Physics
Effect of Organic / Inorganic Gate Materials on the Organic Field-Effect Transistors Performance
...Show More Authors

The choice of gate dielectric materials is fundamental for organic field effect transistors (OFET), integrated circuits, and several electronic applications. The operation of the OFET depends on two essential parameters: the insulation between the semiconductor layer and the gate electrode and the capacitance of the insulator. In this work, the electrical behavior of a pentacene-based OFET with a top contact / bottom gate was studied. Organic polyvinyl alcohol (PVA) and inorganic hafnium oxide (HfO2) were chosen as gate dielectric materials to lower the operation voltage to achieve the next generation of electronic applications. In this study, the performance of the OFET was studied using monolayer and bilayer gate insulators.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Iraqi Journal Of Physics
Effect of Organic / Inorganic Gate Materials on the Organic Field-Effect Transistors Performance
...Show More Authors

The choice of gate dielectric materials is fundamental for organic field effect transistors (OFET), integrated circuits, and several electronic applications. The operation of the OFET depends on two essential parameters: the insulation between the semiconductor layer and the gate electrode and the capacitance of the insulator. In this work, the electrical behavior of a pentacene-based OFET with a top contact / bottom gate was studied. Organic polyvinyl alcohol (PVA) and inorganic hafnium oxide (HfO2) were chosen as gate dielectric materials to lower the operation voltage to achieve the next generation of electronic applications. In this study, the performance of the OFET was studied using monolayer and bilayer gate insulators. To mo

... Show More
View Publication Preview PDF
Crossref