Preferred Language
Articles
/
jbcd-586
Fracture resistance of weakened premolars restored with sonically-activated composite, bulk-filled and incrementally-filled composites(A comparative in vitro study)
...Show More Authors

Background: This study was conducted to assess the effect of sonic activation and bulk placement of resin composite in comparison to horizontal incremental placement on the fracture resistance of weakened premolar teeth. Materials and method: Sixty sound human single-rooted maxillary premolars extracted for orthodontic purposes were used in this study. Teeth were divided into six groups of ten teeth each: Group 1 (sound unprepared teeth as a control group), Group 2 (teeth prepared with MOD cavity and left unrestored), Group 3 (restored with SonicFill™ composite), Group 4 (restored with Quixfil™ composite), Group 5 (restored with Tertic EvoCeram® Bulk Fill composite) and Group 6 (restored with Universal Tetric EvoCeram® composite using horizontal incremental layering technique). Standardized class II MOD cavity was prepared in all teeth except (group 1).After finishing the restorative procedure of each group according to the manufacturer's instructions, all teeth were stored in deionized distilled water in an incubator at 37°C for seven days.All specimens were subjected to compressive axial loading until fracturein a universal testingmachine.Specimens were examined by a stereomicroscope at a magnification of (20X) to evaluate the mode of fracture . Results: The results of this study revealed that the control group exhibited the highest fracture resistance compared to all prepared teeth groups (restored or unrestored) and the differences were statistically highly significant (P<0.01), except with group 3 (which was restored with SonicFill™ composite) where the difference was statistically significant only (P < 0.05).Additionally the results of this study revealed that the prepared unrestored teeth (Group 2) exhibited the lowest fracture resistance compared to all restored groups and the differences were statistically highly significant (P<0.01). Meanwhile, among the restored teeth groups, teeth restored with SonicFill™ composite (group 3) exhibited the highest fracture resistance as compared with all other restored groups and the difference was statistically highly significant (P<0.01). On the other hand, no statistically significant differences in fracture resistance were found among groups 4, 5 and 6, which were restored with Quixfil™ composite, Tetric EvoCeram® Bulk Fill composite and Universal Tetric EvoCeram® composite, respectively (P > 0.05). Group 3and Group 5 showed mostly mixed mode of failure, while Group 4 showed mostly adhesive mode of failure. On the other hand Group 6 teeth showed different modes of failure. Conclusions: SonicFill™ composite can be considered as a viable treatment modality for the restoration of weakened maxillary premolar teeth. On the other hand, the time-consuming incremental layering technique can be substituted with bulk filling, using bulk fill materials (Quixfil™ and Tetric EvoCeram® Bulk Fill) for reinforcement ofweakened maxillary premolars.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Dec 31 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Effect of Particle Size of Sawdust on Behaviour of Sawdust/UPE Composites in Water
...Show More Authors

The aim of the present work is to develop a new class of natural fillers based polymer composites with sawdust (S.D) which used two particle sizes (1.2 μm & 2.3 μm) and different weight percentage from sawdust (10%, 15%, and 20%). The mechanical properties studied include hardness (shore D) for all samples at normal conditions (N.C). The unsaturated polyester (UPE) and its composites samples were immersed in water for  30 days to find the effect of particle size of sawdust (S.D) on the weight gain (Mt %) by water for all the samples, also to find the effect of water on their hardness. The results show that the composite materials of sawdust (S.D) fillers which has particle size (1.2 μm) better than (2.3 μm) particle size bef

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 25 2020
Journal Name
Indian Journal Of Forensic Medicine &amp; Toxicology
Color Stability of Different Aesthetic Resin Composite Materials: A Digital Image Analysis
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Indian Journal Of Forensic Medicine And Toxicology
Color stability of different aesthetic resin composite materials: A digital image analysis
...Show More Authors

Scopus (3)
Scopus
Publication Date
Thu Oct 06 2022
Journal Name
2022 9th International Conference On Electrical Engineering, Computer Science And Informatics (eecsi)
On the Performance of a Composite Right Left Hand Electromagnetic Bandgap Structure
...Show More Authors

This paper presents the design and analysis of composite right left hand (CRLH) electromagnetic bandgap (EBG) structure. The proposed unit cell is consistent of a dielectric substrate with dimensions of 5×5×1 mm 3 made of FR4-Epoxy with εr = 4.4 underneath of a conductive patch with dimensions of 4.4×4.4mm 2 . The unit cell is structured to perform a negative permittivity (ε) and negative permeability (µ) in different bands. The proposed unit cell is developed to 5G systems in the sub-6GHz bands. In this work, a complete analysis of the unit cell in terms of Sparameters, constitutive parameters and refraction index are evaluated using HFSS simulation package based on Finite Element Method (FEM).

View Publication
Scopus (6)
Crossref (4)
Scopus Crossref
Publication Date
Sun Dec 22 2019
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and In-Vitro Evaluation of Darifenacin Hydrobromide as Buccal Films
...Show More Authors

         Darifenacin hydrobromide (DH) is the more recent uroselective M3 receptor antagonist for treating uncomplicated overactive bladder (OAB). This study was aimed to formulate DH as fast dissolving buccal films (FDBFs) using a solvent casting method to enhance patient’s compliance.

         Films were prepared by using polyvinyl alcohol (PVA) as a film forming polymer. Different types and concentrations of superdisintegrants (croscarmellose sodium, sodium starch glycolate, indion 414) were used to select the best formula by studying the physicochemical properties of the films, disintegration time (DT) and percent drug release.

 &nb

... Show More
View Publication Preview PDF
Scopus (25)
Crossref (11)
Scopus Crossref
Publication Date
Mon Dec 25 2023
Journal Name
International Journal Of Drug Delivery Technology
Formulation, Characterization, Optimization, and In-vitro Evaluation of Rosuvastatin as Nanofiber
...Show More Authors

Bioavailability is the objective for an optimum formulation. The target of the analysis is to maximize both the fluidity and disintegration profile of class II weakly compounds that are water-soluble. Anti-dyslipidemia drug rosuvastatin calcium (RC) (bioavailability 20%) through formulating as nanofibers (NFs) using electrospinning (ES) technology. Twenty formulas were prepared, and different polymers and polymer combinations with various concentrations were used such as polyethylene oxide (PEO) polyvinyl pyrrolidine (PVPK-30), and hydroxypropyl methylcellulose (HPMC). Three distinct groups of maximum parameters, including polymeric solution, electrospinning method, and ambient parameter, are capable of influencing the creation alon

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Mon Apr 03 2023
Journal Name
Journal Of Genetic And Environmental Resources Conservation, 2023, 11(1):53-59.
Comparative histomorphological and immunohistochemical study of parathyroid gland in two Iraqi mammals (Weasel, Herpestes javanicus and long-ear hedgehog, Hemiechinus auritus)
...Show More Authors

The present study aimed to investigate the anatomy, histology, and immunohistochemistry of parathyroid gland in two Iraqi mammals (Weasel, Herpestes javanicus and Long-ear hedgehog, Hemiechinus auritus) as a comparative study. A total of (20) animal for each species were used in the present study. Animals collected were immediately anesthesia and dissected to get the parathyroid gland. Methods of Humason and Bancroft and Stevens were employed for histological techniques. Different stains were used (Hematoxylin- Eosin stain-(H & E), Periodic Acid Schiff stain-(PAS), Azan stain, and Methyl Blue stain-(MB)) for staining the histological sections. Anti-calcitonin, code140778 marker used for immune-histochemical study. Results of the present stu

... Show More
Publication Date
Wed Dec 13 2017
Journal Name
Al-khwarizmi Engineering Journal
Using Activated Carbon developed from Iraqi Date Palm Seeds as Permeable Reactive Barrier for Remediation of Groundwater Contaminated with Copper
...Show More Authors

The possibility of using activated carbon developed from date palm seeds wastes as a permeable reactive barrier (PRB) to remove copper from polluted shallow groundwater was investigated. The activated carbon has been developed from date palm seeds by dehydrating methods using concentrated sulfuric acid. Batch tests were performed to characterize the equilibrium sorption properties of new activated carbon in copper-containing aqueous solutions, while the sandy soil (aquifer) was assumed to be inert. Under the studied conditions, the Langmuir isotherm model gives a better fit for the sorption data of copper by activated carbon than other models. At a pilot scale, One-dimensional column experiments were performed, and an integrated model ba

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 26 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Acidity Level on Ions Released and Corrosion of Metal Orthodontic Appliances at Different Time Intervals (An In vitro Study)
...Show More Authors

ABSTRACT Background: This study measured the effects of three parameters pH value, length of immersion and type of archwire on metal ions released from orthodontic appliances. Materials and Methods: Ninety maxillary halves simulated fixed orthodontic appliances that were immersed in artificial saliva of different pH values (6.75, 5 and 3.5) during 28 day period. Three types of archwires were used: stainless steel, nickel titanium and thermal activated nickel titanium. The quantity of nickel and chromium ions was determined with the use of atomic force spectrophotometer while iron ions by spectrophotometer. Each orthodontic set was weighted two times, before the ligation and immersion in the artificial saliva and after 28 days at the end of

... Show More
View Publication Preview PDF
Publication Date
Thu Aug 18 2022
Journal Name
Dental Hypotheses
Microleakage Evaluation of Glass Hybrid Restoration Following Usage of Papain-Based Gel and Ceramic Bur for Caries Removal: An in Vitro Study
...Show More Authors

Scopus Crossref