Background: This study was conducted to assess the effect of sonic activation and bulk placement of resin composite in comparison to horizontal incremental placement on the fracture resistance of weakened premolar teeth. Materials and method: Sixty sound human single-rooted maxillary premolars extracted for orthodontic purposes were used in this study. Teeth were divided into six groups of ten teeth each: Group 1 (sound unprepared teeth as a control group), Group 2 (teeth prepared with MOD cavity and left unrestored), Group 3 (restored with SonicFill™ composite), Group 4 (restored with Quixfil™ composite), Group 5 (restored with Tertic EvoCeram® Bulk Fill composite) and Group 6 (restored with Universal Tetric EvoCeram® composite using horizontal incremental layering technique). Standardized class II MOD cavity was prepared in all teeth except (group 1).After finishing the restorative procedure of each group according to the manufacturer's instructions, all teeth were stored in deionized distilled water in an incubator at 37°C for seven days.All specimens were subjected to compressive axial loading until fracturein a universal testingmachine.Specimens were examined by a stereomicroscope at a magnification of (20X) to evaluate the mode of fracture . Results: The results of this study revealed that the control group exhibited the highest fracture resistance compared to all prepared teeth groups (restored or unrestored) and the differences were statistically highly significant (P<0.01), except with group 3 (which was restored with SonicFill™ composite) where the difference was statistically significant only (P < 0.05).Additionally the results of this study revealed that the prepared unrestored teeth (Group 2) exhibited the lowest fracture resistance compared to all restored groups and the differences were statistically highly significant (P<0.01). Meanwhile, among the restored teeth groups, teeth restored with SonicFill™ composite (group 3) exhibited the highest fracture resistance as compared with all other restored groups and the difference was statistically highly significant (P<0.01). On the other hand, no statistically significant differences in fracture resistance were found among groups 4, 5 and 6, which were restored with Quixfil™ composite, Tetric EvoCeram® Bulk Fill composite and Universal Tetric EvoCeram® composite, respectively (P > 0.05). Group 3and Group 5 showed mostly mixed mode of failure, while Group 4 showed mostly adhesive mode of failure. On the other hand Group 6 teeth showed different modes of failure. Conclusions: SonicFill™ composite can be considered as a viable treatment modality for the restoration of weakened maxillary premolar teeth. On the other hand, the time-consuming incremental layering technique can be substituted with bulk filling, using bulk fill materials (Quixfil™ and Tetric EvoCeram® Bulk Fill) for reinforcement ofweakened maxillary premolars.
Background: This in vitro study compares a novel calcium-phosphate etchant paste to conventional 37% phosphoric acid gel for bonding metal and ceramic brackets by evaluating the shear bond strength, remnant adhesive and enamel damage following water storage, acid challenge and fatigue loading. Material and Methods: Metal and ceramic brackets were bonded to 240 extracted human premolars using two enamel conditioning protocols: conventional 37% phosphoric acid (PA) gel (control), and an acidic calcium-phosphate (CaP) paste. The CaP paste was prepared from β-tricalcium phosphate and monocalcium phosphate monohydrate powders mixed with 37% phosphoric acid solution, and the resulting phase was confirmed using FTIR. The bonded premolars were exp
... Show MoreThe investigation of natural convection in an annular space between two concentric cylinders partially filled with metal foam is introduced numerically. The metal foam is inserted with a new suggested design that includes the distribution of metal foam in the annular space, not only in the redial direction, but also with the angular direction. Temperatures of inner and outer cylinders are maintained at constant value in which inner cylinder temperature is higher than the outer one. Naiver Stokes equation with Boussinesq approximation is used for fluid regime while Brinkman-Forchheimer Darcy model used for metal foam. In addition, the local thermal equilibrium condition in the energy e
A numerical study of the two-dimensional steady free convection flow in an inclined annulus between two concentric square cavities filled with a porous medium is presented in this paper for the case when the side outer walls are kept with differentially heated temperature while the horizontal outer walls and the inner walls are insulated. The heated wall is assumed to have spatial sinusoidal temperature variation about a constant mean value. The Darcy model is used and the fluid is assumed to be a standard Boussinesq fluid. For the Cartesian coordinate system, the governing equations which were used in stream function form are discretized by using the finite difference method with successive under – relaxation method (SUR) and are solv
... Show MoreThis research presents a numerical study to simulate the heat transfer by forced convection as a result of fluid flow inside channel’s with one-sided semicircular sections and fully filled with porous media. The study assumes that the fluid were Laminar , Steady , Incompressible and inlet Temperature was less than Isotherm temperature of a Semicircular sections .Finite difference techniques were used to present the governing equations (Momentum, Energy and Continuity). Elliptical Grid is Generated using Poisson’s equations . The Algebraic equations were solved numerically by using (LSOR (.This research studied the effect of changing the channel shapes on fluid flow and heat transfer in two cases ,the first: cha
... Show MoreBackground: The treatment of dental tissues proceeding to adhesive procedures is a crucial step in the bonding protocol and decides the clinical success ofrestorations. This study was conducted in vitro, with the aim of evaluating thenanoleakage on the interface between the adhesive system and the dentine treated by five surface modalities using scanning electron microscopy and energydispersiveX-ray spectrometry. Materials and methods: Twenty five extracted premolars teeth were selected in the study. Standardized class V cavities were prepared on the buccal and lingual surfaces then the teeth divided into five main groups of (5 teeth in each group n=10) according to the type of dentine surface treatment that was used: Group (A): dentine was
... Show MoreBackground: The treatment of dental tissues proceeding to adhesive procedures is a crucial step in the bonding protocol and decides the clinical success ofrestorations. This study was conducted in vitro, with the aim of evaluating thenanoleakage on the interface between the adhesive system and the dentine treated by five surface modalities using scanning electron microscopy and energydispersiveX-ray spectrometry. Materials and methods: Twenty five extracted premolars teeth were selected in the study. Standardized class V cavities were prepared on the buccal and lingual surfaces then the teeth divided into five main groups of (5 teeth in each group n=10) according to the type of dentine surface treatment that was used: Group (A): dentine was
... Show MoreBackground: The aim of this in vitro study was to evaluate and compare the microleakage between Vertise Flow T M composite material and other conventional (Filtek Z250, riva light cure and SDR) composite materials when restoring CII mesial box only cavity at gingival margin through die penetration test Materials and methods: Forty maxillary first premolars were prepared with class II box design only cavities. Samples were divided into four groups of ten teeth according to material used: group I (FiltekZ250 only). Group II (SDR+FiltekZ250). Group III (Vertise Flow +FiltekZ250). Group IV (Riva light cure+ FiltekZ250). After 24 hrs. immersion in 2% in methylene blue, samples were sectioned and micro leakage was estimated. Results: None of the
... Show MoreClavicle fractures are common injuries in young, active individuals. The majority of the fractures (80% to 85%) occur in the mid-shaft of the bone and account for approximately 2.6% of all fractures. For many years the standard treatment of fracture clavicle was the "figure-of-eight" bandage but several indications for operative fixation, the position of plate fixation for clavicle fracture remains controversial. The aim of this study is to compare between anterio—inferior and anterior-superior plating of mid-shaft displaced clavicle fracture in complications, plate prominence, nonunion, malunion and range of motion. This study is a prospective study conducted in Al-Kindy teaching hospital .A total of 30 patients with fracture mid –sh
... Show MoreThis paper introduces an experimental study on the behavior of confined concrete filled aluminum tubular (CFT) column to improve strength design, ductility and durability of concrete composite structures under concentrically loaded in compression to failure. To achieve this: seven column specimens with same concrete diameter 100mm and without steel reinforcement have been examined through experimental testing, which are used to study the effects of the thickness of the aluminum tube encased concrete ( thickness : 0mm, 2mm, 3mm, 4mm and 5mm with same length of column 450mm), length of column (thickness 5mm and length of column 700mm) and durability (thickness 5mm and length of column 450mm) on the structural behavior of &
... Show More