Background: This study was conducted to assess the effect of sonic activation and bulk placement of resin composite in comparison to horizontal incremental placement on the fracture resistance of weakened premolar teeth. Materials and method: Sixty sound human single-rooted maxillary premolars extracted for orthodontic purposes were used in this study. Teeth were divided into six groups of ten teeth each: Group 1 (sound unprepared teeth as a control group), Group 2 (teeth prepared with MOD cavity and left unrestored), Group 3 (restored with SonicFill™ composite), Group 4 (restored with Quixfil™ composite), Group 5 (restored with Tertic EvoCeram® Bulk Fill composite) and Group 6 (restored with Universal Tetric EvoCeram® composite using horizontal incremental layering technique). Standardized class II MOD cavity was prepared in all teeth except (group 1).After finishing the restorative procedure of each group according to the manufacturer's instructions, all teeth were stored in deionized distilled water in an incubator at 37°C for seven days.All specimens were subjected to compressive axial loading until fracturein a universal testingmachine.Specimens were examined by a stereomicroscope at a magnification of (20X) to evaluate the mode of fracture . Results: The results of this study revealed that the control group exhibited the highest fracture resistance compared to all prepared teeth groups (restored or unrestored) and the differences were statistically highly significant (P<0.01), except with group 3 (which was restored with SonicFill™ composite) where the difference was statistically significant only (P < 0.05).Additionally the results of this study revealed that the prepared unrestored teeth (Group 2) exhibited the lowest fracture resistance compared to all restored groups and the differences were statistically highly significant (P<0.01). Meanwhile, among the restored teeth groups, teeth restored with SonicFill™ composite (group 3) exhibited the highest fracture resistance as compared with all other restored groups and the difference was statistically highly significant (P<0.01). On the other hand, no statistically significant differences in fracture resistance were found among groups 4, 5 and 6, which were restored with Quixfil™ composite, Tetric EvoCeram® Bulk Fill composite and Universal Tetric EvoCeram® composite, respectively (P > 0.05). Group 3and Group 5 showed mostly mixed mode of failure, while Group 4 showed mostly adhesive mode of failure. On the other hand Group 6 teeth showed different modes of failure. Conclusions: SonicFill™ composite can be considered as a viable treatment modality for the restoration of weakened maxillary premolar teeth. On the other hand, the time-consuming incremental layering technique can be substituted with bulk filling, using bulk fill materials (Quixfil™ and Tetric EvoCeram® Bulk Fill) for reinforcement ofweakened maxillary premolars.
|
Background: Drawing blood to measure total serum bilirubin is painful & time consuming. Transcutaneous bilirubinometer working by multiwavelength spectral reflectance from the skin surface on forehead or upper sternum is a quick & painless technique. Objectives: to compare the effectiveness of transcutaneous (over the upper sternum and forehead) and serum bilirubin measurement of neonate with jaundice. Subjects and Methods: This is a cross sectional prospective study. It enrolled 175 jaundiced neonates & excluded those exposed to phototherapy. It was conducted at Child Central Teaching Hospi |
Background: An injury to both the primary and permanent teeth and the supporting structures is one of the most common dental problems seen in children. Splinting is usually difficult or impossible to perform in the primary dentition (due to diminutive room size and lack of patient cooperation). Healing must, therefore, occur despite mobility at the fracture line, usually resulting in interposition of connective tissue. In some instances, infection will occur in the coronal pulp. The present study reported a case of trauma to the anterior primary teeth and alveolar bone in a four year old child. The trauma has caused fracture to the crowns and roots of the primary anterior teeth. The following case was managed in a procedure that may
... Show MoreBackground: An injury to both the primary and permanent teeth and the supporting structures is one of the most common dental problems seen in children. Splinting is usually difficult or impossible to perform in the primary dentition (due to diminutive room size and lack of patient cooperation). Healing must, therefore, occur despite mobility at the fracture line, usually resulting in interposition of connective tissue. In some instances, infection will occur in the coronal pulp. The present study reported a case of trauma to the anterior primary teeth and alveolar bone in a four year old child. The trauma has caused fracture to the crowns and roots of the primary anterior teeth. The following case was managed in a procedure that may prov
... Show MoreBackground: An injury to both the primary and permanent teeth and the supporting structures is one of the most common dental problems seen in children. Splinting is usually difficult or impossible to perform in the primary dentition (due to diminutive room size and lack of patient cooperation). Healing must, therefore, occur despite mobility at the fracture line, usually resulting in interposition of connective tissue. In some instances, infection will occur in the coronal pulp. The present study reported a case of trauma to the anterior primary teeth and alveolar bone in a four year old child. The trauma has caused fracture to the crowns and roots of the primary anterior teeth. The following case was managed in a procedure that may
... Show MoreBackground: Many types of instruments and techniques are used in the instrumentation of the root canal system. These instruments and techniques may extrude debris beyond the apical foramen and may cause post-instrumentation complications. The aim of this study was to evaluate the amount of apically extruded debris resulted by using 4 types of nickel-titanium instruments (WaveOne, TRUShape 3D conforming files, Hyflex CM, and One Shape files) during endodontic instrumentation. Materials and methods: Forty freshly extracted human mandibular second premolar with straight canals and a single apex were collected for this study. All teeth were cut to similar lengths. Pre-weighted glass vials were used as collecting containers. Samples were randoml
... Show MoreResearching the effects of the research and technological development contract, determining its extent and demarcating the boundaries of the obligations imposed in it, is the cornerstone of economic growth and development, because defining these obligations removes the ambiguity and conflict between interests, by stating the rights owed to each party and even trying to reconcile them, or impose protection by specifying guarantees that are compatible with the essence of the R&D contract, For the purpose of studying the subject thoroughly, we will divide this research into two sections. The first is devoted to identifying the parties to the research and technological development contract. As for the other topic, we will explain the obligation
... Show MoreThe goal of the research is to find the optimization in the test of the appropriate cross-over design for the experiment that the researcher is carrying out (under assumption that there are carry-over effects of the treatments) to posterior periods after the application period (which is often assumed to be the first period). The comparison between the double cross-over design and the cross-over design with extra period. The similarities and differences between the two designs were studied by measuring the Relative Efficiency (RE) of the experiment.
In this study a polymeric composite material was prepared by hand
lay-up technique from epoxy resin as a matrix and magnesium oxide
(MgO) as a reinforcement with different weight fraction (5,10,15,
and 20)% to resin. Then the prepared samples were immersed under
normal condition in H2So4(1 M) solution, for periods ranging up to
10 weeks. The result revealed that the diffusion coefficient
decreasing as the concentration of MgO increase. Also we studied
Hardness for the prepared samples before and after immersion. The
result revealed that the hardness values increase as the concentration
of MgO increase, while the hardness for the samples after immersion
in H2SO4 dec
Comparison for the optical energy gap between pure
PMMA , PMMA-TiO2 micro composites and PMMA-TiO2 nano
composites have been investigated under uv – radiation , the
effect of time irradiation (0,6,12,24,48,72,96 and 120) have been
studied for these specimens to study the photic stability .The
results show that the photostability of the PMMA-TiO2
nanocomposite is higher than that of the pure PMMA and
PMMA-TiO2 micro composite under UV-light irradiation