Preferred Language
Articles
/
jbcd-515
Sonographic evaluation of masseter muscle thickness in bruxist and non-bruxist subjects
...Show More Authors

Background: Masseter muscle is a jaw closing muscle of the mandible involved in Para functional habits; which include lip and cheek chewing, fingernail biting, and teeth clenching or bruxism which can be classified as awake or sleep bruxism. Patients with sleep bruxism are three to four times more likely to experience jaw pain and limitation of movement than people who do not experience sleep bruxism. The aim of this study is to measure the thickness of the masseter muscle in bruxist subjects and compare it with non-bruxist subjects by using sonography. Materials and Method: Forty Iraqi subjects with age ranged (20-40) divided into two groups according to the presence of bruxism. Clinical examination was made and masseter muscle thickness measured for both groups using sonography. Results: For bruxist subjects the mean thickness of masseter muscle in relaxation and clenching were (11.7 ± 1.4 mm) and (16.4 ± 1.3 mm). For non bruxist subjects were (11.2 ± 0.4 mm) and (13 ±0.3 mm) respectively. There was an extremely high statistical significant difference in masseter muscle thickness under clenching between bruxist and non bruxist subjects ( it was higher in bruxist group). Masseter muscle thickness under relaxation was significantly lower than that under clenching for both groups. Also there was a positive correlation between masseter muscle thickness and muscle function in bruxism situation. Conclusion: Masseter muscle in bruxist subject was thicker when compared to non-bruxist subject. Masseter muscle thickness was found to be positively correlated with increasing muscle function. The findings of this study indicate that the functional capacity of the masseter muscle affected by bruxism and may be considered as one of the factors influencing muscle thickness.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Relation of Gonial Angle Index to osteoporosis and age using CBCT in female subjects
...Show More Authors

Publication Date
Thu Oct 01 2009
Journal Name
Journal Of The Faculty Of Medicine Baghdad
C.T Scan Measurements of the Lateral and Third Ventricles in Apparently Normal Iraqi Subjects
...Show More Authors

Background: Cerebral ventricular enlargement has been associated with many neurological disorders. Whether this enlargement is primary or secondary to these pathological conditions remains controversial. To define such enlargement, one must have measurements in normal subjects (controls).
Patients and methods: One hundred-twelve (66 male and 46 females) apparently healthy normal subjects, with age ranging between 10-69 years were subjected to C. T scans as part of routine diagnostic workup for complaint of headache or recent minor motor-vehichle accident The ratio (measured as percent) of the ventricular-cross area of the lateral ventricle The maximum width (MTW) of the third ventricle was also deter

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Oct 01 2008
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Effect of aging on growth hormone-leptin axis in normal and obese healthy subjects
...Show More Authors

Background: Growth hormone is a hormone responsible for the normal body growth and development by stimulation protein production in muscle cells and
energy release for breakdown of fat. On the other hand leptin is a newly discovered hormone that is mainly synthesized in adipose tissues it decreases food intake by
causing satiety and promoting energy combustion . Both aging and obesity are associated with a reduction in growth hormone secretion. In the mean time obese
humans have increased circulating leptin.
Objective: The aim of this paper is to shed light on the contribution of these two hormones in the mechanism of aging process in an attempt of improving this
process for a better life at old ages.&n

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jun 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Relation of Gonial Angle Index to osteoporosis and age using CBCT in female subjects
...Show More Authors

background: osteoporosis is a metabolic bone disease that affects women more than men, it is characterized by generalizes reduction of bone mineral density (BMD) leaving a fragile weak bone that is liable to fracture, gonial angle index (GAI) is one of the radio-morphometric indices, it has been controversial whether it is related to bone mineral density or ageing or none of them. The aim of study is to evaluate the role of cone beam computed tomography (CBCT) as a screening tool for diagnosis of osteoporosis and age effect in females using gonial angle index. Material and method: 60 females were divided into 3 groups according to age and (BMD) status into: Group1 (non-osteoporosis 20-30 years), Group2 (non-osteoporosis 50years and above),

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Rawal Medical Journal
HOMA-IR and TyG Index as acute phase reactants in obese and lean subjects
...Show More Authors

Objective: To evaluate biomarkers of insulin resistance and acute phase reactants in obese, overweight and lean subjects and investigate the associations among those biomarkers. Methodology: This cross sectional study included 158 subjects who were stratified into three groups. Group1 comprised 53 obese patients (BMI≥ 30 kg/m2); group 2 were 54 overweight subjects, and group 3 had 51 healthy lean (BMI

View Publication
Publication Date
Fri Sep 04 2020
Journal Name
Al-kindy College Medical Journal
Association of Echocardiographic Epicardial Fat Thickness and Carotid Intima Media Thickness with the Severity of Coronary Artery Disease
...Show More Authors

Background: Coronary artery disease remains the main cause of death despite several preventive programs. Epicardial adipose tissue is a visceral fat depot of the heart located along the large coronary arteries and on the surface of ventricles and apex. Intima media thickness is commonly recognized as the initial stage in the development of atherosclerosis. The development of ultrasound machines, advances in echocardiographic devices and high resolution transducers facilitate comprehensive analysis of epicardial fat thickness (EFT) and carotid –intima media thickness (C-IMT).
Aim: To investigate the relationship of echocardiographic epicardial fat thickness (EFT) and carotid –intima media thickness (C-IMT) with the severity of coro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Apr 02 2006
Journal Name
Journal Of The Faculty Of Medicine Baghdad
exercise induced growth hormone and the effect of age and oxidative stress parameters in Iraqi subjects
...Show More Authors

Background:

View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Annals Of Tropical Medicine And Public Health
Volumetric assessment of maxillary sinus in cleft lip and palate patients in comparison to normal subjects
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Clinical and Sonographic Changes of Parotid Gland in Patients with Type I and Type II Diabetes Mellitus and Its Effect on Physical Properties of Saliva
...Show More Authors

Background: Sialosis described as a specific consequence of diabetes. In diabetic sialosis, the increased volume of the glands is due to the infiltration of adipose in the parenchyma. The B-scan ultrasonography is a generally accepted tool for determining parotid gland enlargement. Oral health is, to a greater extent, dependent on quality and quantity of saliva, both of which may be altered in diabetics. This study was established to detect the enlargement of parotid gland in diabetic patient and study the changes in physical properties of saliva and its relation with the salivary gland enlargement. Subjects, Materials and Methods: A cross-sectional study with highly specified criteria with ages ranged (20-65) years, male and female subject

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Sep 29 2023
Journal Name
Pakistan Journal Of Ophthalmology
Corneal Parameters Measurement in Healthy Subjects Using Scheimpflug and Anterior Segment Optical Coherence Tomography
...Show More Authors

Purpose:  To compare the central corneal thickness (CCT),minimum corneal thickness (MCT) and corneal power measured using theScheimpflug-Placido device and optical coherence tomography (OCT) in healthy eyes. Study Design:  Descriptive observational. Place and Duration of Study:  Al-Kindy college of medicine/university of Baghdad, from June 2021 to April 2022. Methods:  A total of 200 eyes of 200 individuals were enrolled in this study. CCT and MCT measurements were carried out using spectral-domain optical coherence tomography (Optovue) and a Scheimpflug-Placido topographer (Sirius).The agreement between the two approaches was assessed using Bland-Altman analysis in this study. Results:  Mean age was 28.54 ± 6.6 years, me

... Show More
View Publication
Scopus Crossref