Background: Antibacterial action of root canal filling is an important factor for successful root canal treatment, so the aim of the study was to identify and to compare the antimicrobial effect of new sealer (GuttaFlow) to commonly used endodontic sealers (AH Plus, Apexit and EndoFill) against four endodontic microbes. Materials and methods: Twenty patients aged (30-40) years with infected root canals were selected. Four types of microorganisms were isolated from root canals (E faecalis, Staphylococcus aureus, E coli and Candida albicans) and cultured on Mueller Hinton agar Petri-dishes. After identification and isolation of bacterial species, agar diffusion method was used to assess the antibacterial action of four contemporary endodontic sealers used in root canal obturation (AH Plus, Apexit, EndoFill and GuttafFlow). Four wells measuring (5mm depth and 4mm diameter) were created in each Petri dish and sealer was applied into them incubated overnight at 37 C° for bacterial species and 48 hr. at 37 C° for Candida albicans prior to determination of results. Zones of inhibition (no growth of bacteria) were examined around the wells containing sealer & diameters of the zones were measured in mm. The mean of inhibition zones for each group was measured and statistically analyzed among groups using ANOVA and between groups using LSD tests. Results: There was a highly significant difference (P<0.001) among all the tested groups. EndoFill showed the maximum antibacterial action against tested microorganisms. GuttaFlow showed moderate to weak antimicrobial effect, Apexit had weak effect, while AH Plus had no antibacterial action. Conclusion: All the tested materials except AH Plus had antibacterial efficacy against E faecalis, Staphylococcus aureus, E coli and Candida albicans. EndoFill had favorable results among tested sealers and E faecalis was the most resistant bacteria, but none of the materials totally inhibited microbial growth. Thus, endodontic treatment must be performed under aseptic conditions.
A new series of morpholine derivative were prepared by reacting the morpholine with ethyl chloro acetate in the presence triethylamine as an catalyst and benzene as a solvent gave the ethyl morpholin-4-ylacetate reaction with hydrazine hydrate and ethanol as a solvent gave the 2-(morpholin-4-yl)acetohydrazide gave series of Schiff base were prepared by reacting 2-(morpholin-4- yl)acetohydrazide with different aromatic aldehydes and ketons . The new series of (3-9 )were synthesis by reaction of Schiff base (10-14) with chloroacetyl chloride, triethyl amine as an catalyst and 1,4dioxane as a solvent .The chemical structures of the synthesis compound were identified by spectral methods their [ IR ,1H-NMR and 13C-NMR ].The synthesised compoun
... Show MoreThe use of data envelopment analysis method helps to improve the performance of organizations in order to exploit their resources efficiently in order to improve the service quality. represented study a problem in need of the Iraqi Middle East Investment Bank to assess the performance of bank branches, according to the service quality provided, Thus, the importance of the study is to contribute using a scientific and systematic method by applying the data envelopment analysis method in assessing the service quality provided by the bank branches, The study focused on achieving the goal of determining the efficiency of the services quality provided by the bank branches manner which reflect the extent of utilization of a
... Show More
Objective: In order to evaluate the effect of different typed of Separating Medium on the roughness of the fitted
tissue surface of acrylic denture base.
Methodology: Chosen three types of separating medium (Group A Tin foil), (Group B Detery Isolant),(Group C
Cold Mould Seal),used 30 samples of hot cure acrylic resin ,10 samples for each group, after complete curing of
these samples , Profilometer device was used to measure the surface roughness of each sample in all groups.
Results: Using One Way ANOVA Test and LSD test, the results were highly significant in differences among all
groups. Although (Group A) showing lest roughness, (Group B) showing a satisfactory result of roughness, While
(Group C) Showing the hig
The media plays an important role in a number of functions performed by them. Press is one of those media which had and still have a clear role in addressing the various issues, topics, and events. Journalism is no longer as expressed by owners of the liberal theory – it seeks to raise the instincts – but it began to excite the minds of readers to meet their needs. At the same time, it does not neglect the search for the truth and work to deliver it to readers. Some have identified a set of tasks carried out by the press including the interest in public affairs, the needs of the community, work to provide happiness, what is beneficial and useful and combat the negative phenomenon and to address the deviations facing society. The comi
... Show Moreكانت وسائل الاعلام- التقليدية والحديثة – وستبقى وسيلة مهمة لتدفق المعلومات والتعبير عن المشاعر ووصف الاحداث وتشكيل الرأي العام المحلي والدولي عن مختلف القضايا التي تهم الافراد والمجتمعات وفي مقدمتها قضايا العنف بمستوياته كافة ،والتطرف الديني والارهاب بكل مسمياته وستحاول هذه الدراسة ان تقدم اجابات عن اسئلة محددة تمثل الاطار النظري لدراسات مسحية ترصد النظريات التي ترسم الاطر النظرية الت
... Show MoreMany researchers have tackled the shear behavior of Reinforced Concrete (RC) beams by using different kinds of strengthening in the shear regions and steel fibers. In the current paper, the effect of multiple parameters, such as using one percentage of Steel Fibers (SF) with and without stirrups, without stirrups and steel fibers, on the shear behavior of RC beams, has been studied and compared by using Finite Element analysis (FE). Three-dimensional (3D) models of (RC) beams are developed and analyzed using ABAQUS commercial software. The models were validated by comparing their results with the experimental test. The total number of beams that were modeled for validation purposes was four. Extensive pa
... Show MoreThe primary goal of in-situ load testing is to evaluate the safety and performance of a structural system under particular loading conditions. Advancements in building techniques, analytical tools, and monitoring instruments are prompting the evaluation of the appropriate loading value, loading process, and examination criteria. The procedure for testing reinforced concrete (RC) structures on-site, as outlined in the ACI Building Code, involves conducting a 24-h load test and applying specific evaluation criteria. This article detailed a retrofitting project for an RC slab-beams system by utilizing carbon fiber-reinforced polymer (CFRP) sheets to strengthen the structure following a fire incident. The RC structure showed indicators of deter
... Show MoreObjective: To identify causes of maternal death in Mizan Aman and Gebretsadik shawo general hospitals
Methodology: A case control study on 595 charts, 119 cases and 476 controls was conducted in Mizan
Aman & Gebretsadik shawo general hospitals. Data was analyzed by STATA 13.1. Propensity score
matching analysis was used to see causes of maternal death.
Results: Hemorrhage were the main direct causes of maternal death which accounts 47.9% (β =0.58
(95% CI (0.28,0.87)) in hospital but when projected to population based the sample (β =0.26 (95% CI
(0.22,0.31)). Followed by infection 36 (25.21%) (β = 0.50 (95% CI (0.08, 0.92)). when projected to
population based the sample PIH 7.6%) is significant cause (β = 0.16
Background: Measuring implant stability is an important issue in predicting treatment success. Dental implant stability is usually measured through resonance frequency analysis (RFA). Osstell® RFA devices can be used with transducers (Smartpeg™) that correspond to the implants used as well as with transducers designed for application with Penguin® RFA devices (Multipeg™). Aims: This study aims to assess the reliability of a MultiPeg™ transducer with an Osstell® device in measuring dental implant stability. Materials and Methods: Sixteen healthy participants who required dental implant treatment were enrolled in this study. Implant stability was measured by using an Osstell® device with two transducers, namely, Smartpeg™ and M
... Show More