Background: The accuracy of fitness of any dental casting is imperative for the success of any prosthodontic treatment. From the time that dental casting was first introduced, efforts have been made to produce more accurate and better fitted castings with minimal marginal discrepancy. The aim of this in vitro study was to evaluate the effects of three different investing and burnout techniques on the vertical marginal discrepancies ofceramometalcopings invested with two types of phosphate- bonded investments. Materials and methods: Sixty wax patterns were fabricated on a standardized prepared brass die representing an upper central incisor by the aid of a custom-made split mold. Three different investing and burnout techniques were applied for an Iraqi investment and a commercial type; Group I:Ring investing with conventional burnout technique (RC);Group II: Ringless investing with conventional burnout technique (RLC);Group III: Ring investing with accelerated burnout technique (RA).Twenty wax patterns of each group were divided into two subgroups according to the type of investment material used (10 for each subgroup) represented as (B) for the BellaStar XL and (W) for the WYMvest investments. Complete castings were finished and seated on the metal die. The accuracy of fit of each coping was determined by measuring the vertical marginal discrepancies between the finish line on the metal die and the margins of each coping at four specific reference points on the labial, mesial, palatal, and distal aspects of the die by the aid of a light microscope supplied with a digital camera.The arithmetic mean of each three records was computed and regarded as the amount of the marginal discrepancy of each coping and was used as a unit for the statistical analysis. Results: Mean marginal accuracy for W(RLC)was found to be the least (13.839+4.5724 um) while the highest mean value related to B(RLC) (29.033+2.102 um). In general, ANOVA test showed significant results among the mean values of the Binvestment subgroups while LSD test showed non-significance between the (RA) and both the (RC) and (RLC) subgroups. On the other hand, significance was present between the (RLC) and (RA)of the Winvestment subgroups while non-significance was located between the (RC) and both the (RLC) and (RA) subgroups. Comparing similar subgroups of the two tested investments, the Student's t-test showed non-significance between the (RC) subgroups while high significance was located between the (RLC) and (RA) subgroups respectively.Concerning the vertical marginal discrepancy of the copings, applying the (RC) technique for both investments caused non-statistical significance between the labial, mesial, palatal, and distal aspects.The (RLC) technique caused high significance between the four aspects, while the (RA) technique caused non-significance between the labial aspect only and the others. Conclusion: The Iraqi investment generally produced less vertical marginal discrepancies (using the three different investing and burn-out techniques) than the commercial investment.In order to achieve a better marginal fit, it seems that ceramometalcopings invested with the commercial investment tested are better be cast using the conventional ring investing and burnout technique.
Background: Animal bites in humans are an important public health problem. Most of these bites are dog bites. Dog bites in humans are a complex problem embracing public health and animal welfare, both in developed and developing nations. .
Al-kindy Col Med J Vol.8 No.2 2012 P: 149
Objectives: in order to estimate the magnitude of the problem and to understand the epidemiological characteristics of dog bite victims registered in Baghdad city regarding their age, sex, number of registered dog bite victims per month and year along the studied period ( 2006-2010) and also to sniff out any seasonal variation in dog bite attacks .
Methods: A across-sectional study was carried out during January (2011), in the Anti-Rabies clinic of (Pa
This paper proposes a compact, plasmonic-based 4 × 4 nonblocking switch for optical networks. This device uses six 2 × 2 plasmonic Mach-Zehnder switch (MZS), whose arm waveguide is supported by a JRD1 polymer layer as a high electro-optic coefficient material. The 4 × 4 switch is designed in COMSOL environment for 1550 nm wavelength operation. The performance of the proposed switch outperforms those of conventional (nonplasmonic) counterparts. The designed switch yields a compact structure ( 500 × 70 µ m 2 ) having V π L = 12 V · µ m , 1.5 THz optical bandwidth, 7.7 dB insertion loss, and −26.5 dB crosstalk. The capability of the switch to route 8 × 40 Gbps WDM signal is demonstrated successfully.
... Show MoreThe current research seeks to Analyze third intermediate chemistry book following sustainable development standards for academic year (2016-2017). To do this, a list of sustainable development standards that should be included in chemistry book was designed based on the previous studies. The first version of the list consisted of (50) sub-case divided into three standards (social, economic, and environmental) which was exposed to group of experts in teaching chemistry and teaching methods. The list has modified to (43) sub-case. The researcher followed the implicit and explicit meaning in his analysis: one for recording and repetition and the other for frequency. The result showed that third intermediate chemistry book has achieved (20)
... Show MoreThe present study focused mainly on the vibration analysis of composite laminated plates subjected to
thermal and mechanical loads or without any load (free vibration). Natural frequency and dynamic
response are analyzed by analytical, numerical and experimental analysis (by using impact hammer) for
different cases. The experimental investigation is to manufacture the laminates and to find mechanical
and thermal properties of glass-polyester such as longitudinal, transverse young modulus, shear modulus,
longitudinal and transverse thermal expansion and thermal conductivity. The vibration test carried to
find the three natural frequencies of plate. The design parameters of the laminates such as aspect ratio,
thickness
Low-pressure capacitively coupled RF discharge Ar plasma has been studied using Langmuir probe. The electron temperature, electron density and Debay length were calculated under different pressures and electrode gap. In this work the RF Langmuir probe is designed using 4MHz filter as compensation circuit and I-V probe characteristic have been investigated. The pressure varied from 0.07 mbar to 0.1 mbar while electrode gap varied from 2-5 cm. The plasma was generated using power supply at 4MHz frequency with power 300 W. The flowmeter is used to control Argon gas flow in the range of 600 standard cubic centimeters per minute (sccm). The electron temperature drops slowly with pressure and it's gradually decreased when expanding the electro
... Show MoreImprovement of optoelectrical characteristics of phosphorus diffused silicon photodiodes by Q-switched Nd:YAG laser pulses was investigated. Laser pulses have dissolved the precipitation of phosphorus resulted during thermal diffusion process. The experimental data show that responsivity higher than (0.32 A/W) at 850 nm can be achieved after laser annealing with (1.5 MW/cm2) for 6 shots.
This research reports an error analysis of close-range measurements from a Stonex X300 laser scanner in order to address range uncertainty behavior based on indoor experiments under fixed environmental conditions. The analysis includes procedures for estimating the precision and accuracy of the observational errors estimated from the Stonex X300 observations and conducted at intervals of 5 m within a range of 5 to 30 m. The laser 3D point cloud data of the individual scans is analyzed following a roughness analysis prior to the implementation of a Levenberg–Marquardt iterative closest points (LM-ICP) registration. This leads to identifying the level of roughness that was encountered due to the range-finder’s limitations in close
... Show More2 - 5,5 cm mosquito fishes (Gambusia affinis) were collected from brooks of Baghdad university . This study aimed to identify the histological structure and embryonic development of the gas bladder . The results revealed that the gas bladder of the adult fish consists of single chamber, paraphysoclistous , and its wall consist of three layers. The primordium of the gas bladder appears in 2,5 mm fish embryo as an evagination from the right side of endoderm of foreguts wall. This primordium consists of two thecae, inner, is simple columnar epithelium and outer originates from undifferentiated mesoderm. Simultaneously with the appearance of gas gland in the ventral side of the sac in 4 mm embryo, morphological and histological chan
... Show More